Determination of total and unbound concentrations of lopinavir in plasma using liquid chromatography-tandem mass spectrometry and ultrafiltration methods

被引:17
作者
Illamola, S. M. [1 ]
Labat, L. [2 ]
Benaboud, S. [2 ,3 ]
Tubiana, R. [4 ,5 ]
Warszawski, J. [6 ,7 ,8 ]
Treluyer, J. M. [1 ,2 ,3 ,9 ]
Hirt, D. [2 ,3 ]
机构
[1] Hop Tarnier, AP HP, Unite Rech Clin, F-75006 Paris, France
[2] Grp Hosp Pitie Salpetriere, AP HP, Paris Ctr, Serv Pharmacol Clin, F-75634 Paris, France
[3] Univ Paris 05, Sorbonne Paris Cite, EAU08, Paris, France
[4] Hop La Pitie Salpetriere, AP HP, Serv Malad Infect, Paris, France
[5] UPMC Paris 06, Univ Paris 04, UMR Pierre Louis Inst Epidemiol & Publ Hlth S 113, F-75013 Paris, France
[6] INSERM, Ctr Res Epidemiol & Populat Hlth, Equipe VIH & IST, U1018, F-94275 Le Kremlin Bicetre, France
[7] Hop Bicetre, AP HP, Serv Epidemiol & Sante Publ, Le Kremlin Bicetre, France
[8] Univ Paris 11, UMRS 1018, Le Kremlin Bicetre, France
[9] INSERM, CIC 0901, Paris, France
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2014年 / 965卷
关键词
Lopinavir; Unbound fraction; Ultrafiltration; Nonspecific binding; UPLC-MS/MS; HIV-PROTEASE INHIBITORS; REVERSE-TRANSCRIPTASE INHIBITORS; BLOOD MONONUCLEAR-CELLS; ANTIRETROVIRAL DRUGS; SIMULTANEOUS QUANTIFICATION; QUANTITATIVE-ANALYSIS; NONSPECIFIC-BINDING; RITONAVIR; VALIDATION; MS/MS;
D O I
10.1016/j.jchromb.2014.06.034
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Lopinavir is an HIV protease inhibitor with high protein binding (98-99%) in human plasma. This study was designed to develop an ultrafiltration method to measure the unbound concentrations of lopinavir overcoming the non-specific binding issue. A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of total concentrations of lopinavir in plasma was developed and validated, and an adaptation was also optimized and validated for the determination of unbound concentrations. The chromatographic separation was performed with a C-18 column (100 mm x 2.1 mm i.d., 5 mu m particle size) using a mobile phase containing deionized water with formic acid, and acetonitrile, with gradient elution at a flow-rate of 350 mu Lmin(-1). Identification of the compounds was performed by multiple reaction monitoring, using electrospray ionization in positive ion mode. The method was validated over a clinical range of 0.01-1 mu g/mL for human plasma ultrafiltrate and 0.1-15 mu g/mL in human plasma. The inter and intra-assay accuracies and precisions were between 0.23% and 11.37% for total lopinavir concentrations, and between 3.50% and 13.30% for plasma ultrafiltrate (unbound concentration). The ultrafiltration method described allows an accurate separation of the unbound fraction of lopinavir, circumscribing the loss of drug by nonspecific binding (NSB), and the validated LC-MS/MS methodology proposed is suitable for the determination of total and unbound concentrations of lopinavir in clinical practice. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:216 / 223
页数:8
相关论文
共 41 条
  • [31] Protein Binding of Lopinavir and Ritonavir During 4 Phases of Pregnancy: Implications for Treatment Guidelines
    Patterson, Kristine B.
    Dumond, Julie B.
    Prince, Heather A.
    Jenkins, Amanda J.
    Scarsi, Kimberly K.
    Wang, Ruili
    Malone, Stephanie
    Hudgens, Michael G.
    Kashuba, Angela D. M.
    [J]. JAIDS-JOURNAL OF ACQUIRED IMMUNE DEFICIENCY SYNDROMES, 2013, 63 (01) : 51 - 58
  • [32] Development of an assay method for the detection and quantification of protease and non-nucleoside reverse transcriptase inhibitors in plasma and in peripherical blood mononuclear cells by liquid chromatography coupled with ultraviolet or tandem mass spectrometry detection
    Pèlerin, H
    Compain, S
    Duval, X
    Gimenez, F
    Bénech, H
    Mabondzo, A
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 819 (01): : 47 - 57
  • [33] Validation of an Electrospray Ionization LC-MS/MS Method for Quantitative Analysis of Raltegravir, Etravirine, and 9 Other Antiretroviral Agents in Human Plasma Samples
    Quaranta, Sylvie
    Woloch, Christian
    Paccou, Alexandre
    Giocanti, Madeleine
    Solas, Caroline
    Lacarelle, Bruno
    [J]. THERAPEUTIC DRUG MONITORING, 2009, 31 (06) : 695 - 702
  • [34] Modification of the ultrafiltration technique to overcome solubility and non-specific binding challenges associated with the measurement of plasma protein binding of corticosteroids
    Taylor, S
    Harker, A
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 41 (01) : 299 - 303
  • [35] Fast and simultaneous determination of darunavir and eleven other antiretroviral drugs for therapeutic drug monitoring: method development and validation for the determination of all currently approved HIV protease inhibitors and non-nucleoside reverse transcriptase inhibitors in human plasma by liquid chromatography coupled with electrospray ionization tandem mass spectrometry
    ter Heine, Rob
    Aiderden-Los, Carolien G.
    Rosing, Hilde
    Hillebrand, Michel J. X.
    van Gorp, Eric C. M.
    Huitema, Alwin D. R.
    Beijnen, Jos H.
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2007, 21 (15) : 2505 - 2514
  • [36] Lopinavir/Ritonavir Monotherapy as a Nucleoside Analogue-Sparing Strategy to Prevent HIV-1 Mother-to-Child Transmission: The ANRS 135 PRIMEVA Phase 2/3 Randomized Trial
    Tubiana, Roland
    Mandelbrot, Laurent
    Le Chenadec, Jerome
    Delmas, Sandrine
    Rouzioux, Christine
    Hirt, Deborah
    Treluyer, Jean-Marc
    Ekoukou, Dieudonne
    Bui, Eda
    Chaix, Marie-Laure
    Blanche, Stephane
    Warszawski, Josiane
    [J]. CLINICAL INFECTIOUS DISEASES, 2013, 57 (06) : 891 - 902
  • [37] Simple rapid method for quantification of antiretrovirals by liquid chromatography - tandem mass-spectrometry
    Volosov, A
    Alexander, C
    Ting, L
    Soldin, SJ
    [J]. CLINICAL BIOCHEMISTRY, 2002, 35 (02) : 99 - 103
  • [38] Wang C., 2013, J PHARM BIOMED ANAL, V5, P112
  • [39] Validation and application of a high-performance liquid chromatography-tandem mass spectrometric method for simultaneous quantification of lopinavir and ritonavir in human plasma using semi-automated 96-well liquid-liquid extraction
    Wang, Perry G.
    Wei, Jack S.
    Kim, Grace
    Chang, Min
    EI-Shourbagy, Tawakol
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2006, 1130 (02) : 302 - 307
  • [40] Measurement and analysis of unbound drug concentrations
    Wright, JD
    Boudinot, FD
    Ujhelyi, MR
    [J]. CLINICAL PHARMACOKINETICS, 1996, 30 (06) : 445 - 462