Esophageal Damage During Radiofrequency Ablation of Atrial Fibrillation: Impact of Energy Settings, Lesion Sets, and Esophageal Visualization

被引:110
作者
Martinek, M. [1 ]
Bencsik, G. [2 ]
Aichinger, J. [1 ]
Hassanein, S. [1 ]
Schoefl, R. [3 ]
Kuchinka, P. [1 ]
Nesser, H. J. [1 ]
Purerfellner, H. [1 ]
机构
[1] Elisabethinen Univ Teaching Hosp Linz, Dept Cardiol, Linz, Austria
[2] Univ Szeged, Dept Cardiol, Szeged, Hungary
[3] Elisabethinen Univ Teaching Hosp Linz, Dept Gastroenterol, Linz, Austria
关键词
atrial fibrillation; radiofrequency catheter ablation; endoscopy; atrioesophageal fistula; esophagus visualization; VEIN ANTRUM ISOLATION; OPEN IRRIGATION TECHNOLOGY; CATHETER ABLATION; PROCEDURAL PARAMETERS; TEMPERATURE; OUTCOMES; TIP; INTEGRATION; DELIVERY; 8-MM;
D O I
10.1111/j.1540-8167.2008.01426.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Atrioesophageal fistula is an uncommon but often lethal complication of atrial fibrillation (AF) ablation. The purpose of our study was to prospectively investigate the incidence of esophageal ulcerations (ESUL) as well as the impact of energy settings, radiofrequency lesion sets, and direct visualization of the esophagus on esophageal wall injury. Methods and Results: One hundred seventy-five patients, 57.1% paroxysmal AF, 78.5% male, underwent AF ablation and esophagoscopy 24 hours thereafter. We performed a 2:1:1-randomization as follows: Control group: Ablation without visualization of the esophagus using 25 Watt (W) power limit on the posterior wall, n = 70. Visualization and 15 W maximum: Ablation guided by barium visualization of the esophageal course using a limit of 15 W, n = 35. Visualization and 25 W "short burns": Ablation guided by barium visualization using 25 W and "short burns" (max. 5 sec), n = 35. Patients performed under general anesthesia (n = 35) were separated as a nasogastric tube for visualization of the esophagus was used. In total, we found 2.9% of patients (5/175) presenting ESUL. Parameters discriminating the development of ESUL in a specific patient were type of AF, maximum energy delivered, usage of a nasogastric tube, and additional left atrial lines. Visualization of the esophageal course by barium contrast was not able to prevent ESUL. Conclusion: ESUL is a rare finding when using a reasonable energy maximum of 25 W with open-irrigated tip catheters at the posterior wall. Lower energy settings may increase safety without losing efficacy. Additional linear radiofrequency lesions increase the risk of ESUL development. (J Cardiovasc Electrophysiol, Vol. 20, pp. 726-733, July 2009).
引用
收藏
页码:726 / 733
页数:8
相关论文
共 26 条
[2]   Pain and anatomical locations of radiofrequency ablation as predictors of esophageal temperature rise during pulmonary vein isolation [J].
Aryana, Arash ;
Heist, E. Kevin ;
D'Avila, Andre ;
Holmvang, Godtfred ;
Chevalier, Jianping ;
Ruskin, Jeremy N. ;
Mansour, Moussa C. .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2008, 19 (01) :32-38
[3]   Analysis of catheter-tip (8-mm) and actual tissue temperatures achieved during radiofrequency ablation at the orifice of the pulmonary vein [J].
Bunch, TJ ;
Bruce, GK ;
Johnson, SB ;
Sarabanda, A ;
Milton, MA ;
Packer, DL .
CIRCULATION, 2004, 110 (19) :2988-2995
[4]   HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation: Recommendations for personnel, policy, procedures and follow-up [J].
Calkins, Hugh ;
Brugada, Josep ;
Packer, Douglas L. ;
Cappato, Riccardo ;
Chen, Shih-Ann ;
Crijns, Harry J. G. ;
Damiano, Ralph J., Jr. ;
Davies, D. Wyn ;
Haines, David E. ;
Haissaguerre, Michel ;
Iesaka, Yoshito ;
Jackman, Warren ;
Jais, Pierre ;
Kottkamp, Hans ;
Kuck, Karl Heinz ;
Lindsay, Bruce D. ;
Marchlinski, Francis E. ;
McCarthy, Patrick M. ;
Mont, J. Lluis ;
Morady, Fred ;
Nademanee, Koontawee ;
Natale, Andrea ;
Pappone, Carlo ;
Prystowsky, Eric ;
Raviele, Antonio ;
Ruskin, Jeremy N. ;
Shemin, Richard J. .
HEART RHYTHM, 2007, 4 (06) :816-861
[5]   Assessment of temperature, proximity, and course of the esophagus during radiofrequency ablation within the left atrium [J].
Cummings, JE ;
Schweikert, RA ;
Saliba, WI ;
Burkhardt, JD ;
Brachmann, J ;
Gunther, J ;
Schibgilla, V ;
Verma, A ;
Dery, MA ;
Drago, JL ;
Kilicaslan, F ;
Natale, A .
CIRCULATION, 2005, 112 (04) :459-464
[6]   Esophageal luminal temperature measurement underestimates esophageal tissue temperature during radiofrequency ablation within the canine left atrium: Comparison between 8 mm tip and open irrigation catheters [J].
Cummings, Jennifer E. ;
Barrett, Conor D. ;
Litwak, Kenneth N. ;
Di Biase, Luigi ;
Chowdhury, Punam ;
Oh, Seil ;
Ching, Chi Keong ;
Saliba, Walid I. ;
Schweikert, Robert A. ;
Burkhardt, J. David ;
De Marco, Shari ;
Armaganijan, Luciana ;
Natale, Andrea .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2008, 19 (06) :641-644
[7]   Rapid detection and successful treatment of esophageal perforation after radiofrequency ablation of atrial fibrillation: Lessons from five cases [J].
Dagres, Nikolaos ;
Kottkamp, Hans ;
Piorkowski, Christopher ;
Doll, Nicolas ;
Mohr, Friedrich ;
Horlitz, Marc ;
Kremastinos, Dimitrios Th. ;
Hindricks, Gerhard .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2006, 17 (11) :1213-1215
[8]   Comparison of cool tip versus 8-mm tip catheter in achieving electrical isolation of pulmonary veins for long-term control of atrial fibrillation: A prospective randomized pilot study [J].
Dixit, Sanjay ;
Gerstenfeld, Edward P. ;
Callans, David J. ;
Cooper, Joshua M. ;
Lin, David ;
Russo, Andrea M. ;
Verdino, Ralph J. ;
Patel, Vickas V. ;
Kimmel, Stephen E. ;
Ratcliffe, Sarah J. ;
Hsia, Henry H. ;
Nayak, Hemal M. ;
Zado, Erica ;
Ren, Jian-Fang ;
Marchlinski, Francis E. .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2006, 17 (10) :1074-1079
[9]   Catheter ablation of long-lasting persistent atrial fibrillation:: Critical structures for termination [J].
Haïssaguerre, M ;
Sanders, P ;
Hocini, M ;
Takahashi, Y ;
Rotter, M ;
Sacher, F ;
Rostock, T ;
Hsu, LF ;
Bordachar, P ;
Reuter, S ;
Roudaut, R ;
Clémenty, J ;
Jaïs, P .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2005, 16 (11) :1125-1137
[10]   Impact of catheter ablation of the coronary sinus on paroxysmal or persistent atrial fibrillation [J].
Haissaguerre, Michel ;
Hocini, Melene ;
Takahashi, Yoshihide ;
O'Neill, Mark D. ;
Pernat, Andrej ;
Sanders, Prashanthan ;
Jonsson, Anders ;
Rotter, Martin ;
Sacher, Frederic ;
Rostock, Thomas ;
Matsuo, Seiichiro ;
Arantes, Leonardo ;
Lim, Kang Teng ;
Knecht, Sebastien ;
Bordachar, Pierre ;
Laborderie, Julien ;
Jais, Pierre ;
Klein, George ;
Clementy, Jacques .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2007, 18 (04) :378-386