A blurring index for medical images

被引:18
作者
Chen, Tzong-Jer [1 ]
Chuang, Keh-Shih
Chang, Jen-Hao
Shiao, Ya-Hui
Chuang, Chun-Chao
机构
[1] Shu Zen Coll Med & Management, Dept Med Imaging Technol, Kaohsiung 82144, Taiwan
[2] Natl Tsing Hua Univ, Dept Nucl Sci, Hsinchu, Taiwan
[3] Ind Technol Res Inst, Ctr Biomed Engn, Hsinchu, Taiwan
关键词
Moran peak ratio; image blurring; image quality;
D O I
10.1007/s10278-005-8736-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study was undertaken to investigate a useful image blurring index. This work is based on our previously developed method, the Moran peak ratio. Medical images are often deteriorated by noise or blurring. Image processing techniques are used to eliminate these two factors. The denoising process may improve image visibility with a trade-off of edge blurring and may introduce undesirable effects in an image. These effects also exist in images reconstructed using the lossy image compression technique. Blurring and degradation in image quality increases with an increase in the lossy image compression ratio. Objective image quality metrics [e.g., normalized mean square error (NMSE)] currently do not provide spatial information about image blurring. In this article, the Moran peak ratio is proposed for quantitative measurement of blurring in medical images. We show that the quantity of image blurring is dependent upon the ratio between the processed peak of Moran's Z histogram and the original image. The peak ratio of Moran's Z histogram can be used to quantify the degree of image blurring. This method produces better results than the standard gray level distribution deviation. The proposed method can also be used to discern blurriness in an image using different image compression algorithms.
引用
收藏
页码:118 / 125
页数:8
相关论文
共 16 条
[1]   Methods of measurement of image quality in teleultrasound [J].
Burgul, R ;
Gilbert, FJ ;
Undrill, PE .
BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (876) :1306-1312
[2]   A statistical method for evaluation quality of medical images: a case study in bit discarding and image compression [J].
Chen, TJ ;
Chuang, KS ;
Chiang, YC ;
Chang, JH ;
Liu, RS .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2004, 28 (04) :167-175
[3]  
Chen TJ, 2003, J DIGIT IMAGING, V16, P210, DOI 10.1007/sl0278-003-1652-0
[4]   A novel image quality index using Moran I statistics [J].
Chen, TJ ;
Chuang, KS ;
Wu, J ;
Chen, SC ;
Hwang, IM ;
Jan, ML .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (08) :N131-N137
[5]   ASSESSMENT OF NOISE IN A DIGITAL IMAGE USING THE JOIN-COUNT STATISTIC AND THE MORAN TEST [J].
CHUANG, KS ;
HUANG, HK .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (02) :357-369
[6]  
CLIFF AD, 1981, SPATIAL PROCESS MODE, P3
[7]  
Erickson BJ, 2000, IRREVERSIBLE COMPRES
[8]   Image data compression [J].
Goldberg, MA .
JOURNAL OF DIGITAL IMAGING, 1998, 11 (03) :230-232
[9]  
GONZALEZ RC, 1992, DIGITAL IMAGE PROCES, P3
[10]   QUALITY ASSESSMENT OF DSA, ULTRASOUND AND CT DIGITAL IMAGES COMPRESSED WITH THE JPEG PROTOCOL [J].
OKKALIDES, D ;
EFREMIDES, S .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (09) :1407-1421