Mercury detection in air using a coated piezoelectric sensor

被引:33
|
作者
Ruys, DP [1 ]
Andrade, JF [1 ]
Guimaraes, OM [1 ]
机构
[1] USP, FFCLRP, Dept Quim, BR-14040901 Ribeirao Preto, Brazil
基金
巴西圣保罗研究基金会;
关键词
mercury detection; piezoelectric sensor; QCM;
D O I
10.1016/S0003-2670(99)00673-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Three different methods to produce standardized vapors of mercury were tested and compared for posterior determination of metal, using a piezoelectric sensor (QCM). The generation techniques employed were: saturation, syringe dilution and permeation tube. Gold-coated piezoelectric crystals, without any substrate, were initially tested as sensor, based on the selective affinity of gold by mercury. Later, using a permeation tube as source of metal, some substances were investigated as possible substrates capable of interaction with mercury vapor. The best material found was a mixture (1 : 1 v/v) of palladium-II chloride solution (saturated in acetone) and tetrahydroxyethylethylenediamine (THEED) 50% v/v in acetone. The analytical curve is linear in the concentration range from 2.0 to 7.0 ppm of Hg. Good linearities (r = 0.9952 and 0.9979) and sensitivities (102 and 149 Hz/ppm) were found for exposure times of 20 and 40 s, respectively. it was shown that the technique has potential application as a small, rugged, sensible and portable mercury vapor sensor. (C)2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:95 / 100
页数:6
相关论文
共 50 条
  • [31] Measurement of organic compounds in air using activated carbon coated sensor
    Choi, KJ
    Kim, YH
    ISIE 2001: IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS PROCEEDINGS, VOLS I-III, 2001, : 516 - 519
  • [32] Flexible strain sensor for air muscles using Polypyrrole coated rubber
    Tjahyono, Arief P.
    Aw, Kean. C.
    Travas-Sejdic, Jadranka
    Li, K. C.
    ELECTROACTIVE POLYMER ACTUATORS AND DEVICES (EAPAD) 2010, 2010, 7642
  • [33] PIEZOELECTRIC CRYSTAL FILM BADGE FOR MONITORING MERCURY IN AIR
    SCHEIDE, EP
    TAYLOR, JK
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1975, 170 (AUG24): : 10 - 10
  • [34] DETECTION OF TOLUENE DIISOCYANATE IN AIR WITH A COATED PIEZOELECTRIC CRYSTAL .1. A STUDY OF COATING MATERIALS
    ALDER, JF
    ISAAC, CA
    ANALYTICA CHIMICA ACTA, 1981, 129 (AUG) : 163 - 174
  • [35] DETERMINATION OF QUININE IN SOME PHARMACEUTICAL PREPARATIONS USING A RING-COATED PIEZOELECTRIC SENSOR
    NIE, LH
    ZHANG, XT
    YAO, SZ
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1992, 10 (07) : 529 - 533
  • [36] Development of a chemical vapor sensor using piezoelectric quartz crystals with coated unusual lipids
    Yano, K
    Yoshitake, H
    Bornscheuer, UT
    Schmid, RD
    Ikebukuro, K
    Yokoyama, K
    Masuda, Y
    Karube, I
    ANALYTICA CHIMICA ACTA, 1997, 340 (1-3) : 41 - 48
  • [37] Numerical simulation on a coated piezoelectric sensor interacting with a crack
    Xiao, ZM
    Bai, J
    FINITE ELEMENTS IN ANALYSIS AND DESIGN, 2002, 38 (08) : 691 - 706
  • [38] Improved determination of gaseous divalent mercury in ambient air using KCl coated denuders
    Xinbin Feng
    J. Sommar
    K. Gårdfeldt
    O. Lindqvist
    Fresenius' Journal of Analytical Chemistry, 2000, 366 : 423 - 428
  • [39] Sampling and determination of gas phase divalent mercury in the air using a KCl coated denuder
    Xiao, Z
    Sommar, J
    Wei, S
    Lindqvist, O
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 358 (03): : 386 - 391
  • [40] Improved determination of gaseous divalent mercury in ambient air using KCl coated denuders
    Feng, XB
    Sommar, J
    Gårdfeldt, K
    Lindqvist, O
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 366 (05): : 423 - 428