Dosimetric effects of roll rotational setup errors on lung stereotactic ablative radiotherapy using volumetric modulated arc therapy

被引:11
|
作者
Lee, Jaegi [1 ,2 ]
Kim, Jung-In [2 ,3 ,4 ,5 ]
Ye, Sung-Joon [1 ,3 ]
Kim, Hak Jae [3 ,4 ,6 ]
Carlson, Joel [1 ,2 ]
Park, Jong Min [2 ,3 ,4 ,5 ]
机构
[1] Seoul Natl Univ, Grad Sch Convergence Sci & Technol, Dept Transdisciplinary Studies, Program Biomed Radiat Sci, Seoul, South Korea
[2] Seoul Natl Univ, Coll Med, Biomed Res Inst, Seoul, South Korea
[3] Seoul Natl Univ Hosp, Dept Radiat Oncol, Seoul 110744, South Korea
[4] Seoul Natl Univ, Med Res Ctr, Inst Radiat Med, Seoul, South Korea
[5] Adv Inst Convergence Technol, Ctr Convergence Res Robot, Suwon, South Korea
[6] Seoul Natl Univ, Dept Radiat Oncol, Coll Med, Seoul, South Korea
关键词
BODY RADIATION-THERAPY; IMAGE-GUIDED RADIOTHERAPY; CONE-BEAM CT; CANCER; METASTASES; GUIDANCE; POSITION; PATIENT;
D O I
10.1259/bjr.20140862
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To evaluate the dosimetric effects of roll-rotational setup errors of stereotactic ablative radiotherapy (SABR) for lung cancer using volumetric modulated arc therapy (VMAT). Methods: A total of 23 lung SABR cases were evaluated retrospectively. Each of the planning CT images was intentionally rotated by +/- 1 degrees, +/- 2 degrees and +/- 3 degrees. After that, to simulate the translational couch correction, rotated CT images were moved along the x, y and z axis to match the centroid of the target volume in the rotated CT images with that in the original CT images. The differences in D-95% and V-100% of the target volume, D-0.35cc of spinal cord, D-0.35cc and D-5cc of oesophagus and V-20Gy of lung between the original and the rotated CT images were calculated. Results: The average differences in D95% and V100% of target volume, D0.35cc of spinal cord, D0.35cc and D5cc of oesophagus and V-20Gy of lung were -0.3% +/- 0.4% and -0.7% +/- 2.4%, 1.6 +/- 27.9 cGy, -1.6 +/- 37.6cGy, 15.9 +/- 25.3cGy and 0.0%+/- 0.1%, respectively. The dosimetric changes in organs at risk (OARs) near the target volume were sometimes considerable due to roll-rotational setup errors, despite the translational correction, and those were patient specific. Conclusion: In the case of coplanar VMAT for lung SABR, dosimetric changes to the target volume due to roll-rotational setup errors could be compensated by translational correction, whereas those to the OARs could not in some cases. Advances in knowledge: Roll-rotational setup errors would increase the dose to OARs despite the translational correction.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Improving Delivery Accuracy of Stereotactic Body Radiotherapy to a Moving Tumor Using Simplified Volumetric Modulated Arc Therapy
    Ko, Young Eun
    Cho, Byungchul
    Kim, Su Ssan
    Song, Si Yeol
    Choi, Eun Kyung
    Ahn, Seung Do
    Yi, Byongyong
    PLOS ONE, 2016, 11 (06):
  • [22] Intrafraction Motion in Stereotactic Body Radiation Therapy for Non-Small Cell Lung Cancer: Intensity Modulated Radiation Therapy Versus Volumetric Modulated Arc Therapy
    Rossi, Maddalena M. G.
    Peulen, Heike M. U.
    Belderbos, Jose S. A.
    Sonke, Jan-Jakob
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 95 (02): : 835 - 843
  • [23] Dosimetric study for spine stereotactic body radiation therapy: magnetic resonance guided linear accelerator versus volumetric modulated arc therapy
    Yadav, Poonam
    Musunuru, Hima B.
    Witt, Jacob S.
    Bassetti, Michael
    Bayouth, John
    Baschnagel, Andrew M.
    RADIOLOGY AND ONCOLOGY, 2019, 53 (03) : 362 - 368
  • [24] Volumetric modulated arc therapy versus conventional intensity modulated radiation therapy for stereotactic spine radiotherapy: A planning study and early clinical data
    Kuijper, Ingrid T.
    Dahele, Max
    Senan, Suresh
    Verbakel, Wilko F. A. R.
    RADIOTHERAPY AND ONCOLOGY, 2010, 94 (02) : 224 - 228
  • [25] Cardiac Exposure in the Dynamic Conformal Arc Therapy, Intensity-Modulated Radiotherapy and Volumetric Modulated Arc Therapy of Lung Cancer
    Ming, Xin
    Feng, Yuanming
    Liu, Huan
    Zhang, Ying
    Zhou, Li
    Deng, Jun
    PLOS ONE, 2015, 10 (12):
  • [26] Dosimetric Study On Volumetric Modulated Arc Therapy for Left Breast Using Four Partial Arc Technique
    Boopathy, R.
    Sakthivel, V.
    Mani, S.
    Padmanaban, S.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [27] Radiotherapy for maxillary sinus carcinoma: dosimetric comparison of volumetric modulated arc therapy with 0° and 90° collimator intensity modulated radiation therapy
    Sang, Yong
    Shan, Guoping
    Shao, Kainan
    Hu, Fujun
    Chen, Jing
    JOURNAL OF RADIATION ONCOLOGY, 2020, 9 (1-2) : 53 - 58
  • [28] Gamma analysis with a gamma criterion of 2%/1 mm for stereotactic ablative radiotherapy delivered with volumetric modulated arc therapy technique: a single institution experience
    Kim, Jung-in
    Chun, Minsoo
    Wu, Hong-Gyun
    Chie, Eui Kyu
    Kim, Hak Jae
    Kim, Jin Ho
    Park, Jong Min
    ONCOTARGET, 2017, 8 (44) : 76076 - 76084
  • [29] Dosimetric investigation of whole-brain radiotherapy with helical intensity modulated radiation therapy and volumetric modulated arc therapy for scalp sparing
    Shirata, Ryosuke
    Inoue, Tatsuya
    Sugimoto, Satoru
    Saito, Anneyuko, I
    Omura, Motoko
    Minagawa, Yumiko
    Sasai, Keisuke
    BJR OPEN, 2023, 5 (01):
  • [30] Dosimetric Evaluation of Intensity-Modulated Radiotherapy, Volumetric Modulated Arc Therapy, and Helical Tomotherapy for Hippocampal-Avoidance Whole Brain Radiotherapy
    Rong, Yi
    Evans, Josh
    Xu-Welliver, Meng
    Pickett, Cadron
    Jia, Guang
    Chen, Quan
    Zuo, Li
    PLOS ONE, 2015, 10 (04):