Iontophoretic Fraction Collection for Coupling Capillary Zone Electrophoresis with Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry

被引:34
作者
Busnel, Jean-Marc [1 ]
Josserand, Jacques [1 ]
Lion, Niels [1 ]
Girault, Hubert H. [1 ]
机构
[1] Ecole Polytech Fed Lausanne, Lab Electrochim Phys & Analyt, CH-1015 Lausanne, Switzerland
关键词
ON-PLATE DIGESTION; MALDI-TOF; ELECTROSPRAY; TIME; DEPOSITION; INTERFACE;
D O I
10.1021/ac900128q
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An automated fraction collection interface has been developed for coupling capillary electrophoresis (CE) with matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS)This fraction collection approach is based on electromigration and diffusion and does not rely on the presence of a liquid junction, sheath-liquid, electro-osmotic flow, or a superimposed hydrodynamic flow. Neutrally coated capillary with negligible electroosmosis can thus be used to provide high-efficiency separations of biological compounds. The in-capillary separation resolution is totally independent from the spotting process. CE-separated species can be collected either in a multiwell plate or directly on a MALDI target. In the present work, an eight-protein mixture, submitted to trypsin proteolysis, has been used as a sample test and separations have been conducted in 50 mu m i.d. neutrally coated capillaries. As compared to direct MALDI MS analysis, the integration of CE improved the number of detected peptides from 36 to 87 and the average sequence coverage from 24% to 38%. Internal calibration was used, and an average mass accuracy of 16.1 ppm is reported. Finally, diffusion-migration numerical simulations of the iontophoretic fraction collection process have been carried out.
引用
收藏
页码:3867 / 3872
页数:6
相关论文
共 32 条
[1]   Capillary zone electrophoresis of glycopeptides under controlled electroosmotic flow conditions coupled to electrospray and matrix-assisted laser desorption/ionization mass spectrometry [J].
Amon, S ;
Plematl, A ;
Rizzi, A .
ELECTROPHORESIS, 2006, 27 (5-6) :1209-1219
[2]   Glycosylation analysis of glycoproteins and proteoglycans using capillary electrophoresis-mass spectrometry strategies [J].
Amon, Sabine ;
Zamfir, Alina D. ;
Rizzi, Andreas .
ELECTROPHORESIS, 2008, 29 (12) :2485-2507
[3]   TiO2 Printed Aluminum Foil: Single-Use Film for a Laser Desorption/Ionization Target Plate [J].
Bi, Hongyan ;
Qiao, Liang ;
Busnel, Jean-Marc ;
Devaud, Valerie ;
Liu, Baohong ;
Girault, Hubert H. .
ANALYTICAL CHEMISTRY, 2009, 81 (03) :1177-1183
[4]   Sheathless reverse-polarity capillary electrophoresis-electrospray-mass spectrometry for analysis of underivatized glycoconjugates [J].
Bindila, L ;
Peter-Katalinic, J ;
Zamfir, A .
ELECTROPHORESIS, 2005, 26 (7-8) :1488-1499
[5]   Electrokinetic supercharging for highly efficient peptide preconcentration in capillary zone electrophoresis [J].
Busnel, Jean-Marc ;
Lion, Niels ;
Girault, Hubert H. .
ELECTROPHORESIS, 2008, 29 (07) :1565-1572
[6]   COAXIAL CAPILLARY AND CONDUCTIVE CAPILLARY INTERFACES FOR COLLECTION OF FRACTIONS-ISOLATED BY CAPILLARY ELECTROPHORESIS [J].
CHIU, RW ;
WALKER, KL ;
HAGEN, JJ ;
MONNIG, CA ;
WILKINS, CL .
ANALYTICAL CHEMISTRY, 1995, 67 (22) :4190-4196
[7]   Capillary electrophoresis-mass spectrometry for the analysis of intact proteins [J].
Haselberg, Rob ;
de Jong, Gerhardus J. ;
Somsen, Govert W. .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1159 (1-2) :81-109
[8]   CONTINUOUS SAMPLE COLLECTION IN CAPILLARY ZONE ELECTROPHORESIS BY COUPLING THE OUTLET OF A CAPILLARY TO A MOVING SURFACE [J].
HUANG, XH ;
ZARE, RN .
JOURNAL OF CHROMATOGRAPHY, 1990, 516 (01) :185-189
[9]   USE OF AN ON-COLUMN FRIT IN CAPILLARY ZONE ELECTROPHORESIS - SAMPLE COLLECTION [J].
HUANG, XH ;
ZARE, RN .
ANALYTICAL CHEMISTRY, 1990, 62 (05) :443-446
[10]   Progress in capillary electrophoresis coupled to matrix-assisted laser desorption/ionization - time of flight mass spectrometry [J].
Huck, CW ;
Bakry, R ;
Huber, LA ;
Bonn, GK .
ELECTROPHORESIS, 2006, 27 (11) :2063-2074