Efficacy of dexamethasone intravitreal implant for the treatment of diabetic macular edema

被引:16
|
作者
Bonnin, Sophie [1 ]
Dupas, Benedicte [1 ]
El Sanharawi, Mohamed [2 ]
Perol, Julien [1 ]
Erginay, Ali [1 ]
Tadayoni, Ramin [1 ]
Massin, Pascale [1 ]
机构
[1] Lariboisiere Hosp, Dept Ophthalmol, F-75010 Paris, France
[2] Quinze Vingts Natl Ophthalmol Hosp, Ophthalmol Dept 5, Paris, France
关键词
Dexamethasone; Diabetes; Intravitreal implant; Macular edema; Vitrectomy; RANIBIZUMAB PLUS PROMPT; TRIAMCINOLONE ACETONIDE; FOLLOW-UP; CONTROLLED-TRIAL; DEFERRED LASER; PHOTOCOAGULATION; THICKNESS; 3-YEAR;
D O I
10.5301/ejo.5000581
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess the efficacy of a single dexamethasone intravitreal implant (Dex-I) injection for the treatment of diabetic macular edema (DME). Methods: This was a retrospective chart review of 39 eyes (34 consecutive patients). Best-corrected visual acuity (BCVA), central macular thickness (CMT), and increase in intraocular pressure (IOP) (> 24 mm Hg) were analyzed before treatment and 2 and 4 months after injection. Results: Preoperative mean CMT was 559 +/- 111 mu m and decreased to 338 +/- 84 and 477 +/- 140 mu m 2 and 4 months after injection, respectively. Although all eyes showed a significant decrease in CMT 2 months after injection (p < 0.0001), a recurrence of the macular edema was observed 4 months after injection in 79% of eyes. Mean BCVA improvement (logMAR) was 0.13 +/- 0.18 (p < 0.0001) and 0.07 +/- 0.21 (p = 0.049) 2 and 4 months after injection, respectively, without significant difference between vitrectomized and nonvitrectomized eyes. Eight eyes (21%) developed reversible increase in IOP 2 months after injection. Conclusions: Thirty percent of DME eyes had gained more than 2 logMAR lines 2 months after Dex-I injection and safety was good. Visual acuity gain was maintained 4 months after injection despite a recurrence of edema in most cases.
引用
收藏
页码:448 / 453
页数:6
相关论文
共 50 条
  • [21] Title: efficacy of intravitreal dexamethasone implant on hard exudate in diabetic macular edema
    Chang Ki Yoon
    Min Sagong
    Jae Pil Shin
    Sang Joon Lee
    Joo Eun Lee
    Ji Eun Lee
    Inyoung Chung
    Woo Jin Jeong
    Kang Yeun Pak
    Hyun Woong Kim
    BMC Ophthalmology, 21
  • [22] Effectiveness of Intravitreal Dexamethasone Implant Treatment for Diabetic Macular Edema in Vitrectomized Eyes
    Ozdemir, Huseyin Baran
    Hasanreisoglu, Murat
    Yuksel, Murat
    Ertop, Mestan
    Gurelik, Gokhan
    Ozdek, Sengul
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2019, 49 (06): : 323 - 327
  • [23] Dexamethasone intravitreal implant for diabetic macular edema: indications for a PRN regimen of treatment
    Panozzo, Giacomo
    Gusson, Elena
    Panozzo, Giorgio
    Dalla Mura, Giulia
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2015, 25 (04) : 347 - 351
  • [24] Role of implants in the treatment of diabetic macular edema: focus on the dexamethasone intravitreal implant
    Cebeci, Zafer
    Kir, Nur
    DIABETES METABOLIC SYNDROME AND OBESITY, 2015, 8 : 555 - 566
  • [25] Twelve-month treatment with intravitreal dexamethasone implant for diabetic macular edema
    Sarao, Valentina
    Veritti, Daniele
    Lanzetta, Paolo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [26] Sustained-release dexamethasone intravitreal implant for treatment of diabetic macular edema
    Kuppermann, Baruch D.
    EXPERT REVIEW OF OPHTHALMOLOGY, 2011, 6 (01) : 11 - 20
  • [27] Letter to the editor: dexamethasone intravitreal implant in the treatment of diabetic macular edema Reply
    Dugel, Pravin U.
    Bandello, Francesco
    Loewenstein, Anat
    CLINICAL OPHTHALMOLOGY, 2015, 9 : 2121 - 2121
  • [28] PHARMACOECONOMIC ANALYSIS OF DEXAMETHASONE INTRAVITREAL IMPLANT FOR THE TREATMENT OF DIABETIC MACULAR EDEMA IN RUSSIA
    Kolbin, A.
    Galankin, T.
    Kaleev, A., I
    VALUE IN HEALTH, 2017, 20 (05) : A158 - A158
  • [29] Comments to: Long-term efficacy and safety of intravitreal dexamethasone implant for the treatment of diabetic macular edema
    Calugaru, Dan
    Calugaru, Mihai
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2016, 26 (06) : E171 - E172
  • [30] Comparison of the efficacy of intravitreal Anti-VEGF versus intravitreal dexamethasone implant in treatment resistant diabetic Macular Edema
    Hakan Koc
    Atilla Alpay
    Suat Hayri Ugurbas
    BMC Ophthalmology, 23