Distal Femoral Physeal Fixation: Are Smooth Pins Really Safe?

被引:32
作者
Dahl, William J. [1 ]
Silva, Selina [1 ]
Vanderhave, Kelly L. [1 ]
机构
[1] Univ Michigan, Dept Orthopaed Surg, Ann Arbor, MI 48109 USA
基金
英国惠康基金;
关键词
physeal bar; physeal fracture; EPIPHYSEAL PLATE; GROWTH; FRACTURES; RECONSTRUCTION; RABBITS;
D O I
10.1097/BPO.0000000000000083
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Distal femoral physeal fractures have a high incidence of physeal arrest. Several factors have been postulated to contribute to this high incidence, including fracture type, displacement, the undulating nature of the physis, and fracture reduction/fixation. The purpose of this study was to determine whether the position of percutaneous smooth pins across the physis contributes to physeal bar formation. Methods: The previously validated New Zealand white rabbit model was used. Power analysis determined that 30 animals were required. All animals had a constant 0.045 smooth Kirschner (K) wire placed under fluoroscopic guidance from the distal lateral femur across the physis centrally. A second 0.045 K-wire was placed in a cross-pin configuration from the medial side in one of 2 positions: zone 1-crossing the physis centrally or zone 2-crossing the physis peripherally. Pins were removed after 4 weeks and micro computed tomography was performed at 8 weeks to assess for physeal bar formation. Histologic analysis was performed to confirm bar formation. Results: Two physeal bars (7%) were seen after removal of the constant (lateral pin). The peripheral pin resulted in bar formation in 2 animals (13%) and the central pin in 1 animal (7%). A chi(2) test was performed; there was no statistically significant difference between zones in terms of bar formation (P=0.5428). Conclusions: Injury to the growth plate after distal femoral fracture may be unavoidable. Treatment is aimed to minimize further injury to the physis. Cross-pinning with smooth K-wires results in a low rate of physeal injury. Pins that cross the physis both centrally and peripherally appear to have the same risk for physeal bar formation. Clinical Relevance: This study reveals that physeal bar formation can be seen with smaller than previously reported cross-sectional damage to the distal femoral physis. This study highlights the need to carefully select and perform fixation of the distal femoral physis with as little additional trauma to the physis as possible.
引用
收藏
页码:134 / 138
页数:5
相关论文
共 30 条
  • [21] Pediatric distal third tibial shaft fractures: a comparison of surgical fixation methods and incidence of concomitant physeal fractures
    McGraw-Heinrich, Jessica A.
    Ezeokoli, Ekene U.
    Mitchell, Parker
    Silverstein, Rachel S.
    Smith, Brian G.
    JOURNAL OF PEDIATRIC ORTHOPAEDICS-PART B, 2023, 32 (04): : 393 - 400
  • [22] The biomechanical comparison of screw fixation and cross pinning methods in salter harris type 2 distal femoral fractures using the finite element method Fixation biomechanics in pediatric distal femoral fractures
    Oner, Kerim
    Ozer, Alaettin
    Paksoy, Ahmet Emre
    ANNALS OF CLINICAL AND ANALYTICAL MEDICINE, 2021, 12 : 205 - 209
  • [23] Distal femoral dome varus osteotomy: Surgical technique with minimal dissection and external fixation
    Luna-Pizarro, Daniel
    Moreno-Delgado, Francisco
    Carlos De la Fuente-Zuno, Juan
    Meraz-Lares, Gerardo
    KNEE, 2012, 19 (02) : 99 - 102
  • [24] Is transphyseal intramedullary fixation of the distal radius in pediatric fractures a safe procedure? An MRI study
    Giordano, Marco
    Florio, Michela
    Careri, Silvia
    Cirillo, Marco
    Aulisa, Angelo Gabriele
    Pezzoli, Fabio Massimo
    Falciglia, Francesco
    FRONTIERS IN SURGERY, 2025, 12
  • [25] Early fixation failure of locked plating in complex distal femoral fractures: Root causes analysis
    Hsu, Chun-Liang
    Yang, Jui-Jung
    Yeh, Tsu-Te
    Shen, Hsain-Chung
    Pan, Ru-Yu
    Wu, Chia-Chun
    JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 2021, 120 (01) : 395 - 403
  • [26] Distal Femoral Physeal Bar Resection Combined With Guided Growth for the Treatment of Angular Limb Deformity Associated With Growth Arrest: A Preliminary Report
    Javier Masquijo, J.
    Allende, Victoria
    Ferreyra, Andres
    Hernandez Bueno, Juan C.
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2020, 40 (10) : E958 - E962
  • [27] Use of a Modified Intramedullary Pinning Technique for Distal Femoral Physeal Salter-Harris Type I and II Fracture Management: A Retrospective Study of 31 Cats
    Bondonny, Laura
    Jacqmin, Maxime
    Ferrand, Francois-Xavier
    Taroni, Mathieu
    Rivier, Pablo
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2024, 37 (02) : 107 - 114
  • [28] Corrective osteotomy for procurvatum deformity caused by distal femoral physeal fracture malunion stabilised with String-of-Pearls locking plates: results in two dogs and a review of the literature
    Kim, S. E.
    Lewis, D. D.
    AUSTRALIAN VETERINARY JOURNAL, 2014, 92 (03) : 75 - 80
  • [29] Establishing Safe Extra-articular Parameters for Cortical Button Distal Fixation During Ulnar Collateral Ligament Reconstruction
    Hooper, Perry O.
    Warren, Jared
    Silko, Christopher
    Frangiamore, Salvatore J.
    King, Dominic
    Farrow, Lutul D.
    Schickendantz, Mark S.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2019, 47 (11) : 2699 - 2703
  • [30] Ipsilateral distal third femoral shaft fracture and retrograde intramedullary fixation are not absolute contraindications to anterolateral thigh flap harvest: A case report
    Pan, ZhaoHui
    Jiang, PingPing
    Zhao, YuXiang
    Xue, Shan
    Gao, Peng
    JPRAS OPEN, 2022, 31 : 99 - 104