An efficient approach for glomerular filtration rate assessment in older adults

被引:7
作者
Martus, Peter [1 ]
Ebert, Natalie [2 ]
van der Giet, Markus [3 ]
Jakob, Olga [4 ]
Schaeffner, Elke S. [2 ]
机构
[1] Univ Tubingen, Inst Clin Epidemiol & Med Biostat, UKT Tubingen, D-72078 Tubingen, Germany
[2] Charite, Div Nephrol & Intens Care Med, D-13353 Berlin, Germany
[3] Charite Campus Benjamin Franklin, Div Nephrol, Charite Univ Med, Berlin, Germany
[4] Charite Campus Benjamin Franklin, Inst Biostat & Clin Epidemiol, Charite Univ Med, Berlin, Germany
关键词
cystatin C; glomerular filtration rate; iohexol; kidney function; older adults; CHRONIC KIDNEY-DISEASE; CYSTATIN-C; RENAL-DISEASE; PLASMA-CLEARANCE; ELDERLY-PATIENTS; CONTRAST AGENT; CKD-EPI; IOHEXOL; EQUATIONS; SINGLE;
D O I
10.1111/bcp.12331
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
AIMS Assessment of glomerular filtration rate (GFR) is crucial because the GFR value defines the stage of chronic kidney disease and determines the adjustment of drug dosage. The aim was to investigate a new method for the accurate determination of GFR in older adults based on the combination of an exogenous filtration marker, iohexol, and an endogenous marker, serum creatinine or cystatin C. METHODS We combined variables for the estimation of GFR with a reduced set of measurements of the marker iohexol. In a population-based sample of 570 subjects (>= 70 years old) from the Berlin Initiative Study (BIS), we investigated the following: (i) the BIS1 and BIS2 equations based on age, gender and serum creatinine with or without serum cystatin C; (ii) equations based on one or two iohexol measurements; and (iii) equations based on the combination of variables from BIS1 or BIS2 with iohexol measurements. The reference standard was based on eight iohexol measurements. The cut-off value of 60 ml min(-1) (1.73 m)(-2) was chosen to assess accuracy. Equations were constructed using a learning sample (n = 285) and an independent validation sample (n = 285). RESULTS Misclassification rates were 17.2% (BIS1), 11.6% (BIS2), 14.7% [iohexol measurement at 240 min (iohexol(240))], 7.0% (iohexol(240) combined with variables included in BIS1) and 6.7% (iohexol(240) combined with variables included in BIS2). Misclassification rates did not decrease significantly after inclusion of two or three iohexol measurements. CONCLUSIONS Combined strategies for the determination of GFR lead to a relevant increase of diagnostic validity.
引用
收藏
页码:384 / 392
页数:9
相关论文
共 28 条
  • [1] PLASMA AND RENAL CLEARANCE OF IOHEXOL - A STUDY ON THE REPRODUCIBILITY OF A METHOD FOR THE GLOMERULAR-FILTRATION RATE
    ARVIDSSON, A
    HEDMAN, A
    [J]. SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1990, 50 (07) : 757 - 761
  • [2] Comparison of GFR Measurements Assessed From Single Versus Multiple Samples
    Bird, Nicholas J.
    Peters, Christina
    Michell, A. Robert
    Peters, A. Michael
    [J]. AMERICAN JOURNAL OF KIDNEY DISEASES, 2009, 54 (02) : 278 - 288
  • [3] Validation of the Lund-Malmo, Chronic Kidney Disease Epidemiology (CKD-EPI) and Modification of Diet in Renal Disease (MDRD) equations to estimate glomerular filtration rate in a large Swedish clinical population
    Bjork, Jonas
    Jones, Ian
    Nyman, Ulf
    Sjostrom, Per
    [J]. SCANDINAVIAN JOURNAL OF UROLOGY AND NEPHROLOGY, 2012, 46 (03): : 212 - 222
  • [5] IOHEXOL CLEARANCE FOR THE DETERMINATION OF GLOMERULAR-FILTRATION RATE IN CLINICAL-PRACTICE - EVIDENCE FOR A NEW GOLD STANDARD
    BROWN, SCW
    OREILLY, PH
    [J]. JOURNAL OF UROLOGY, 1991, 146 (03) : 675 - 679
  • [6] Performance of iohexol determination in serum and urine by HPLC: Validation, risk and uncertainty assessment
    Cavalier, Etienne
    Rozet, Eric
    Dubois, Nathalie
    Charlier, Corinne
    Hubert, Philippe
    Chapelle, Jean-Paul
    Krzesinski, Jean-Marie
    Delanaye, Pierre
    [J]. CLINICA CHIMICA ACTA, 2008, 396 (1-2) : 80 - 85
  • [7] Renal function assessment in older adults
    Drenth-van Maanen, A. Clara
    Jansen, Paul A. F.
    Proost, Johannes H.
    Egberts, Toine C. G.
    van Zuilen, Arjan D.
    van der Stap, Dawi
    van Marum, Rob J.
    [J]. BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 2013, 76 (04) : 616 - 623
  • [8] GLOMERULAR-FILTRATION RATE - A COMPARISON BETWEEN CR-EDTA CLEARANCE AND A SINGLE SAMPLE TECHNIQUE WITH A NONIONIC CONTRAST AGENT
    ERIKSSON, CG
    KALLNER, A
    [J]. CLINICAL BIOCHEMISTRY, 1991, 24 (03) : 261 - 264
  • [9] Plasma cystatin C determinations in a healthy elderly population
    Finney, H
    Bates, CJ
    Price, CP
    [J]. ARCHIVES OF GERONTOLOGY AND GERIATRICS, 1999, 29 (01) : 75 - 94
  • [10] Guidelines for the measurement of glomerular filtration rate using plasma sampling
    Fleming, JS
    Zivanovic, MA
    Blake, GM
    Burniston, M
    Cosgriff, PS
    [J]. NUCLEAR MEDICINE COMMUNICATIONS, 2004, 25 (08) : 759 - 769