Efficiency of heat pump systems of air conditioning for removing excessive moisture

被引:4
|
作者
Bezrodny, Mikhail [1 ]
Prytula, Natalia [1 ]
Tsvietkova, Maria [1 ]
机构
[1] Natl Tech Univ Ukraine, Igor Sikorsky Kyiv Polytech Inst, Pobedy 37, UA-03056 Kiev, Ukraine
关键词
Heat pump; Air conditioning systems; Comfortable conditions; Production facilities with excess moisture;
D O I
10.24425/ather.2019.129546
中图分类号
O414.1 [热力学];
学科分类号
摘要
The conditions of efficient use of heat pumps in air conditioning systems are considered in order to ensure the established temperature and relative humidity of air in premises with the removal of excess moisture in the warm or hot periods of the year. For this purpose, a thermodynamic analysis of heat pump air conditioning schemes with exhaust air recirculation through a condenser and through a heat pump evaporator has been carried out. To determine the potential capabilities of such schemes to maintain comfortable conditions in the production room, a numerical analysis of their operating parameters, depending on the temperature and relative humidity of external atmospheric air, was performed. It has been shown that recirculation of exhaust air through the heat pump evaporator allows to maintain the given conditions in the morn in a wider range of parameters of external atmospheric air. In addition, it has been shown that such a scheme requires less specific energy consumption for the operation of heat pump, which means that it is more efficient.
引用
收藏
页码:151 / 165
页数:15
相关论文
共 50 条
  • [21] The use of phase change materials in domestic heat pump and air-conditioning systems for short term storage: A review
    Moreno, Pere
    Sole, Cristian
    Castell, Albert
    Cabeza, Luisa F.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2014, 39 : 1 - 13
  • [22] THE USE OF WARM OUTFLOW VENTILATION AIR FOR INCREASE AN OPEN AIR HEAT PUMP EFFICIENCY
    Ilsters, Andrievs
    Ziemelis, Imants
    Putans, Henriks
    13TH INTERNATIONAL SCIENTIFIC CONFERENCE ON ENGINEERING FOR RURAL DEVELOPMENT, 2014, : 306 - 311
  • [23] Heating performance of air preheated integrated ground water heat pump air-conditioning system
    Lian M.
    Tan Y.
    Wang L.
    Chen F.
    Cao Y.
    Huagong Xuebao/CIESC Journal, 2023, 74 : 311 - 319
  • [24] Fuel-cell ejector heat pump integrated system for annual air conditioning
    Lazzarin, Renato
    Noro, Marco
    Zamboni, Lorenzo
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2006, 1 (01) : 79 - 91
  • [25] Development of an adsorption chiller and heat pump for domestic heating and air-conditioning applications
    Nunez, Tomas
    Mittelbach, Walter
    Henning, Hans-Martin
    APPLIED THERMAL ENGINEERING, 2007, 27 (13) : 2205 - 2212
  • [26] Performance evaluation of a variable frequency heat pump air conditioning system for electric bus
    Peng, Qinghong
    Du, Qungui
    International Journal of Fluid Machinery and Systems, 2015, 8 (01) : 13 - 22
  • [27] Testing the Efficiency of a Heat Pump with Radiant Systems in Heating Mode
    Simko, Martin
    Petras, Dusan
    Szabo, Daniel
    Zivner, Lukas
    Takacs, Jan
    PERIODICA POLYTECHNICA-MECHANICAL ENGINEERING, 2024, 68 (04): : 320 - 327
  • [28] A review on the application of horizontal heat pipe heat exchangers in air conditioning systems in the tropics
    Yau, Y. H.
    Ahmadzadehtalatapeh, M.
    APPLIED THERMAL ENGINEERING, 2010, 30 (2-3) : 77 - 84
  • [29] Waste heat recovery on central air conditioning systems in hotel buildings
    Ngie, Tay Seow
    Ma Tingquan
    Zheng Ailing
    Zhang Weiting
    ECOS 2006: PROCEEDINGS OF THE 19TH INTERNATIONAL CONFERENCE ON EFFICIENCY, COST, OPTIMIZATION, SIMULATION AND ENVIRONMENTAL IMPACT OF ENERGY SYSTEMS, VOLS 1-3, 2006, : 841 - +
  • [30] Assessment of exergy efficiency and Sustainability Index of an air-water heat pump
    Dincer, I.
    Naterer, G. F.
    INTERNATIONAL JOURNAL OF EXERGY, 2010, 7 (01) : 37 - 50