Testing and simulation of a low-temperature air-source heat pump operating in a thermal buffer zone

被引:22
作者
Touchie, Marianne F. [1 ]
Pressnail, Kim D. [1 ]
机构
[1] Univ Toronto, Dept Civil Engn, Toronto, ON M5S 1A4, Canada
关键词
Air source heat pump; MURB; Energy efficiency; Suite-based equipment; Energy model; ENERGY;
D O I
10.1016/j.enbuild.2014.02.015
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Air-source heat pumps (ASHPs) are commonly used in temperate climates throughout Europe and Asia to provide energy efficient heating and cooling. However, ASHPs have not been widely adopted for heating in colder climates because the coefficient of performance (COP) is lower when outdoor temperatures are colder. While many researchers are working on improving the cold-temperature performance ofASHPs by altering the design of the equipment, this work examines an innovative way to improve performance by operating an existing 'off-the-shelf ASHP within a thermal buffer zone. This paper shows that operating an ASHP in a thermal buffer zone (TBZ) created by an enclosed balcony space can improve the COP in cold temperatures. An ASHP operating in a TBZ was tested in a climate chamber where the performance was monitored under a variety of climatic conditions. The temperature drawdown of the TBZ and the associated impact on the COP were observed. The TBZ solar heat gain rates required to improve the COP were identified for a range of exterior temperatures. Then, a suite-based energy model was developed and calibrated to simulate the performance of the ASHP operating in the TBZ. The model provided a reasonable prediction of the ASHP performance below 10 degrees C. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:149 / 159
页数:11
相关论文
共 27 条
[1]  
Abdelaziz O, 2012, ASHRAE TRAN, V118, P34
[2]  
Air Instrument Resources Ltd, OP CAL INSTR MP SER
[3]  
[Anonymous], 2004, HEAT COOL HEAT PUMP
[4]  
BizEE, 2013, CUST DEGR DAY DAT
[5]   Cold climate ductless heat pump performance [J].
Bugbee, J., 1600, Taylor & Francis Group LLC (110) :47-57
[6]  
Bush J, 2012, ASHRAE TRAN, V118, P620
[7]  
Canada Mortgage and Housing Corporation, 2006, CMHC RES HIGHL TECHN
[8]  
Congress of the United States Office of Technology Assessment, ASS TECHN LOC DEV, P55
[9]   Investigation of some renewable energy and exergy parameters for two Geothermal District Heating Systems [J].
Coskun, C. ;
Oktay, Z. ;
Dincer, I. .
INTERNATIONAL JOURNAL OF EXERGY, 2011, 8 (01) :1-15
[10]  
Daikin AC Americas Inc., ENG DAT SPLIT HEAT P