Ultralow-Dose Chest Computed Tomography for Pulmonary Nodule Detection First Performance Evaluation of Single Energy Scanning With Spectral Shaping

被引:204
作者
Gordic, Sonja [1 ]
Morsbach, Fabian [1 ]
Schmidt, Bernhard [2 ,3 ]
Allmendinger, Thomas [2 ]
Flohr, Thomas [2 ,4 ]
Husarik, Daniela [1 ]
Baumueller, Stephan [1 ]
Raupach, Rainer [2 ]
Stolzmann, Paul [1 ]
Leschka, Sebastian [5 ]
Frauenfelder, Thomas [1 ]
Alkadhi, Hatem [1 ]
机构
[1] Univ Zurich Hosp, Inst Diagnost & Intervent Radiol, CH-8091 Zurich, Switzerland
[2] Siemens Healthcare, Computed Tomog Div, Forchheim, Germany
[3] Univ Erlangen Nurnberg, D-91054 Erlangen, Germany
[4] Univ Tubingen, Tubingen, Germany
[5] Kantonsspital St Gallen, Inst Radiol, St Gallen, Switzerland
关键词
computed tomography; image reconstruction; lung; radiation dosage; low dose; ITERATIVE RECONSTRUCTION TECHNIQUE; CORONARY CT ANGIOGRAPHY; IMAGE QUALITY; HELICAL CT; REDUCTION; IMPACT; NOISE;
D O I
10.1097/RLI.0000000000000037
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose The purpose of this study was to evaluate the image quality and sensitivity of ultralow radiation dose single-energy computed tomography (CT) with tin filtration for spectral shaping and iterative reconstructions for the detection of pulmonary nodules in a phantom setting. Methods Single-energy CT was performed using third-generation dual-source CT (SOMATOM Force; 2 x 192 slices) at 70 kVp, 100 kVp with tin filtration (100Sn kVp), and 150Sn kV with tube current-time product adjustments resulting in standard dose (CT volume dose index, 3.1 mGy/effective dose, 1.3 mSv at a scan length of 30 cm), 1/10th dose level (0.3 mGy/0.13 mSv), and 1/20th dose level (0.15 mGy/0.06 mSv). An anthropomorphic chest phantom simulating an intermediate-sized adult with randomly distributed solid pulmonary nodules of various sizes (2-10 mm; attenuation, 75 HU at 120 kVp) was used. Images were reconstructed with advanced model-based iterative reconstruction (ADMIRE; strength levels 3 and 5) and were compared with those acquired with second-generation dual-source CT at 120 kVp (reconstructed with filtered back projection) and sinogram-affirmed iterative reconstruction (strength level 3) at the lowest possible dose at 120 kVp (CT volume dose index, 0.28 mGy). One blinded reader measured image noise, and 2 blinded, independent readers determined overall image quality on a 5-grade scale (1 = nondiagnostic to 5 = excellent) and marked nodule localization with confidence rates on a 5-grade scale (1 = unsure to 5 = high confidence). The constructional drawing of the phantom served as reference standard for calculation of sensitivity. Two patients were included, for proof of concept, who were scanned with the 100Sn kVp protocol at the 1/10th and 1/20th dose level. Results Image noise was highest in the images acquired with second-generation dual-source CT and reconstructed with filtered back projection. At both the 1/10th and 1/20th dose levels, image noise at a tube voltage of 100Sn kVp was significantly lower than in the 70 kVp and 150Sn kV data sets (ADMIRE 3, P < 0.01; ADMIRE 5, P < 0.05). Sensitivity of nodule detection was lowest in images acquired with second-generation dual-source CT at 120 kVp and the lowest possible dose. Protocols at 100Sn kVp and ADMIRE 5 showed highest sensitivity at the 1/10th and 1/20th dose levels. Highest numbers of false-positives occurred in second-generation dual-source CT images (range, 12-15), whereas lowest numbers occurred in the 1/10th and 1/20th dose data sets acquired with third-generation dual-source CT at 100Sn kVp and reconstructed with ADMIRE strength levels 3 and 5 (total of 1 and 0 false-positives, respectively). Diagnostic confidence at 100Sn kVp was significantly higher than at 70 kVp or 150Sn kV (ADMIRE 3, P < 0.05; ADMIRE 5, P < 0.01) at both the 1/10th and 1/20th dose levels. Images of the 2 patients scanned with 100Sn kVp at the 1/10th and 1/20th dose levels were of diagnostic quality. Conclusions Our study suggests that chest CT for the detection of pulmonary nodules can be performed with third-generation dual-source CT producing high image quality, sensitivity, and diagnostic confidence at a very low effective radiation dose of 0.06 mSv when using a single-energy protocol at 100 kVp with spectral shaping and when using advanced iterative reconstruction techniques.
引用
收藏
页码:465 / 473
页数:9
相关论文
共 35 条
  • [1] Dose Reduction Strategies for Thoracic Multidetector Computed Tomography Background, Current Issues, and Recommendations
    Bankier, Alexander A.
    Tack, Denis
    [J]. JOURNAL OF THORACIC IMAGING, 2010, 25 (04) : 278 - 288
  • [2] Low-dose CT of the lung: potential value of iterative reconstructions
    Baumueller, Stephan
    Winklehner, Anna
    Karlo, Christoph
    Goetti, Robert
    Flohr, Thomas
    Russi, Erich W.
    Frauenfelder, Thomas
    Alkadhi, Hatem
    [J]. EUROPEAN RADIOLOGY, 2012, 22 (12) : 2597 - 2606
  • [3] Computed Tomography of the Lung in the High-Pitch Mode Is Breath Holding Still Required?
    Baumueller, Stephan
    Alkadhi, Hatem
    Stolzmann, Paul
    Frauenfelder, Thomas
    Goetti, Robert
    Schertler, Thomas
    Plass, Andre
    Falk, Volkmar
    Feuchtner, Gudrun
    Scheffel, Hans
    Desbiolles, Lotus
    Leschka, Sebastian
    [J]. INVESTIGATIVE RADIOLOGY, 2011, 46 (04) : 240 - 245
  • [4] Effect of radiation dose and iterative reconstruction on lung lesion conspicuity at MDCT: Does one size fit all?
    Botelho, Marcos Paulo Ferreira
    Agrawal, Rishi
    Gonzalez-Guindalini, Fernanda Dias
    Hart, Eric M.
    Patel, Suresh K.
    Toere, Hueseyin Guerkan
    Yaghmai, Vahid
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (11) : E726 - E733
  • [5] Dose Reduction in Helical CT: Dynamically Adjustable z-Axis X-Ray Beam Collimation
    Christner, Jodie A.
    Zavaletta, Vanessa A.
    Eusemann, Christian D.
    Walz-Flannigan, Alisa I.
    McCollough, Cynthia H.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (01) : W49 - W55
  • [6] PRECONDITIONING METHODS FOR IMPROVED CONVERGENCE-RATES IN ITERATIVE RECONSTRUCTIONS
    CLINTHORNE, NH
    PAN, TS
    CHIAO, PC
    ROGERS, WL
    STAMOS, JA
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1993, 12 (01) : 78 - 83
  • [7] Impact of iterative reconstruction on image quality and radiation dose in multidetector CT of large body size adults
    Desai, Gaurav S.
    Uppot, Raul N.
    Yu, Elaine W.
    Kambadakone, Avinash R.
    Sahani, Dushyant V.
    [J]. EUROPEAN RADIOLOGY, 2012, 22 (08) : 1631 - 1640
  • [8] Detection of pulmonary nodules by multislice computed tomography: improved detection rate with reduced slice thickness
    Fischbach, F
    Knollmann, F
    Griesshaber, V
    Freund, T
    Akkol, E
    Felix, R
    [J]. EUROPEAN RADIOLOGY, 2003, 13 (10) : 2378 - 2383
  • [9] The National Lung Screening Trial: Overview and Study Design
    Gatsonis, Constantine A.
    [J]. RADIOLOGY, 2011, 258 (01) : 243 - 253
  • [10] Radiation dose of non-enhanced chest CT can be reduced 40% by using iterative reconstruction in image space
    Hu, X. H.
    Ding, X. F.
    Wu, R. Z.
    Zhang, M. M.
    [J]. CLINICAL RADIOLOGY, 2011, 66 (11) : 1023 - 1029