共 50 条
Determination of ribavirin in serum using highly selective solid-phase extraction and high-performance liquid chromatography
被引:44
作者:
Svensson, JO
[1
]
Bruchfeld, A
Schvarcz, R
Ståhle, L
机构:
[1] Huddinge Univ Hosp, Karolinska Inst, Div Clin Pharmacol, Dept Med Lab Sci & Technol, SE-14186 Stockholm, Sweden
[2] Huddinge Univ Hosp, Karolinska Inst, Dept Renal Med, SE-14186 Stockholm, Sweden
[3] Huddinge Univ Hosp, Karolinska Inst, Dept Infect Dis, SE-14186 Stockholm, Sweden
关键词:
ribivirin;
solid-phase extraction;
high-performance liquid chromatography hepatitis C;
D O I:
10.1097/00007691-200004000-00013
中图分类号:
R446 [实验室诊断];
R-33 [实验医学、医学实验];
学科分类号:
1001 ;
摘要:
A rapid assay for determination of ribavirin in serum using solid-phase extraction (SPE), high-performance liquid chromatography (HPLC), and UV-detection was developed. The SPE uses phenylboronic acid columns with an approximately 100% recovery for ribavirin. The concentration-peak area relation was linear (r > 0.995), from 1 to 64 mu M in 100 mu L serum. The limit of detection was 0.1 mu M. The intraassay CV was 3.2% at treatment levels (9.7 mu M) and 11.5% at 0.4 mu M The method is used to monitor patients undergoing ribavirin treatment for hepatitis C (HCV). Samples from HCV-infected patients with and without renal dysfunction have been analyzed without interference of endogenous compounds. It is concluded that the method is useful for routine therapeutic drug monitoring.
引用
收藏
页码:215 / 218
页数:4
相关论文