Solid extraction-electrothermal atomic absorption spectrometric determination of selenium in environmental samples

被引:11
作者
Robles, LC [1 ]
Aller, AJ [1 ]
机构
[1] UNIV LEON,DEPT BIOCHEM & MOL BIOL,E-24071 LEON,SPAIN
关键词
selenium determination; slurry electrothermal atomic absorption spectrometry; bacteria; microorganisms; environmental sample; water; coal fly ash;
D O I
10.2116/analsci.12.783
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
[No abstract available]
引用
收藏
页码:783 / 787
页数:5
相关论文
共 14 条
[1]   SPECTRAL INTERFERENCES ON THE DETERMINATION OF SELENIUM BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY [J].
ALLER, AJ ;
GARCIAOLALLA, C .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (05) :753-760
[2]   SELENITE AND SELENATE QUANTIFICATION BY HYDRIDE GENERATION ATOMIC-ABSORPTION SPECTROMETRY, ION CHROMATOGRAPHY, AND COLORIMETRY [J].
BLAYLOCK, MJ ;
JAMES, BR .
JOURNAL OF ENVIRONMENTAL QUALITY, 1993, 22 (04) :851-857
[3]   SPECIATION AND PRECONCENTRATION OF TRACE-ELEMENTS WITH IMMOBILIZED ALGAE FOR ATOMIC-ABSORPTION SPECTROPHOTOMETRIC DETECTION [J].
ELMAHADI, HAM ;
GREENWAY, GM .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (04) :547-551
[4]   THE EFFECT OF METAL CHLORIDES, SULFATES AND NITRATES ON ATOMIZATION OF SELENIUM IN GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
GARCIAOLALLA, C ;
ROBLES, LC ;
ALLER, AJ .
ANALYTICAL SCIENCES, 1991, 7 (04) :611-615
[5]   DETERMINATION OF SELENIUM IN COAL FLY ASHES BY GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY USING A CADMIUM-PALLADIUM CHEMICAL MODIFIER [J].
GARCIAOLALLA, C ;
ROBLES, LC ;
ALEMANY, MT ;
ALLER, AJ .
ANALYTICA CHIMICA ACTA, 1991, 247 (01) :19-25
[6]   ALTERNATIVE MERCURY PALLADIUM CHEMICAL MODIFIER FOR THE DETERMINATION OF SELENIUM IN COAL FLY-ASH BY GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
GARCIAOLALLA, C ;
ALLER, AJ .
ANALYTICA CHIMICA ACTA, 1992, 259 (02) :295-303
[7]   PEAK PROFILE CHARACTERISTICS AND ATOMIZATION MECHANISMS FOR SELENIUM IN THE PRESENCE OF MERCURY FOR GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
GARCIAOLALLA, C ;
ALLER, AJ .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 342 (1-2) :70-75
[8]   DETERMINATION OF SELENIUM IN BIOLOGICAL MATRICES USING A KINETIC CATALYTIC METHOD [J].
GOKMEN, IG ;
ABDELQADER, E .
ANALYST, 1994, 119 (04) :703-708
[9]   DETERMINATION OF SELENIUM IN BLOOD BY ZEEMAN GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY USING A PALLADIUM ASCORBIC ACID CHEMICAL MODIFIER [J].
KNOWLES, MB ;
BRODIE, KG .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (04) :511-516
[10]   PREATOMIZATION BEHAVIOR OF SE(-II), SE(IV), AND SE(VI) IN THE GRAPHITE-FURNACE WITHOUT AND WITH MATRIX MODIFIERS [J].
KRIVAN, V ;
KUCKENWAITZ, M .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 342 (09) :692-697