Surface dose extrapolation measurements with radiographic film

被引:16
作者
Butson, MJ [1 ]
Cheung, T
Yu, PKN
Currie, M
机构
[1] City Univ Hong Kong, Dept Phys & Mat Sci, Kowloon, Hong Kong, Peoples R China
[2] Illawarra Canc Care Ctr, Dept Phys Med, Wollongong, NSW 2500, Australia
关键词
D O I
10.1088/0031-9155/49/13/N03
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Assessment of surface dose delivered from radiotherapy x-ray beams for optimal results should be performed both inside and outside the prescribed treatment fields. An extrapolation technique can be used with radiographic film to perform surface dose assessment for open field high energy x-ray beams. This can produce an accurate two-dimensional map of surface dose if required. Results have shown that the surface percentage dose can be estimated within +/-3% of parallel plate ionization chamber results with radiographic film using a series of film layers to produce an extrapolated result. Extrapolated percentage dose assessment for 10 cm, 20 cm and 30 cm square fields was estimated to be 15% +/- 2%, 29% +/- 3% and 38% +/- 3% at the central axis and relatively uniform across the treatment field. The corresponding parallel plate ionization chamber measurements are 16%, 27% and 37%, respectively. Surface doses are also measured outside the treatment field which are mainly due to scattered electron contamination. To achieve this result, film calibration curves must be irradiated to similar x-ray field sizes as the experimental film to minimize quantitative variations in film optical density caused by varying x-ray spectrum with field size.
引用
收藏
页码:N197 / N201
页数:5
相关论文
共 10 条
[1]  
Butson Martin J., 1996, Australasian Physical and Engineering Sciences in Medicine, V19, P74
[2]   Extrapolated surface dose measurements with radiochromic film [J].
Butson, MJ ;
Yu, PKN ;
Metcalfe, PE .
MEDICAL PHYSICS, 1999, 26 (03) :485-488
[3]   Radiochromic film for medical radiation dosimetry [J].
Butson, MJ ;
Yu, PKN ;
Cheung, T ;
Metcalfe, P .
MATERIALS SCIENCE & ENGINEERING R-REPORTS, 2003, 41 (3-5) :61-120
[4]   A SOLID WATER PHANTOM MATERIAL FOR RADIOTHERAPY X-RAY AND GAMMA-RAY BEAM CALIBRATIONS [J].
CONSTANTINOU, C ;
ATTIX, FH ;
PALIWAL, BR .
MEDICAL PHYSICS, 1982, 9 (03) :436-441
[5]  
HARPER N R, 1991, Australasian Physical and Engineering Sciences in Medicine, V14, P141
[6]   Electron contamination and build-up doses in conformal radiotherapy fields [J].
Hounsell, AR ;
Wilkinson, JM .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (01) :43-55
[7]   ELECTRON CONTAMINATION FROM PHOTON-BEAM COLLIMATORS [J].
NILSSON, B ;
BRAHME, A .
RADIOTHERAPY AND ONCOLOGY, 1986, 5 (03) :235-244
[8]   DESIGN OF PARALLEL PLATE ION CHAMBERS FOR BUILDUP MEASUREMENTS IN MEGAVOLTAGE PHOTON BEAMS [J].
RAWLINSON, JA ;
ARLEN, D ;
NEWCOMBE, D .
MEDICAL PHYSICS, 1992, 19 (03) :641-648
[9]   Directional dependence in film dosimetry: radiographic and radiochromic film [J].
Suchowerska, N ;
Hoban, P ;
Butson, M ;
Davison, A ;
Metcalfe, P .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (05) :1391-1397
[10]   Electron contamination in 8 and 18 MV photon beams [J].
Zhu, TC ;
Palta, JR .
MEDICAL PHYSICS, 1998, 25 (01) :12-19