On angiography with a Thomson laser-electron X-ray generator

被引:2
作者
Vinogradov, A. V. [1 ]
Vinogradov, S. L. [1 ]
D'yachkov, N. V. [1 ,2 ]
Polunina, A. V. [3 ]
Postnov, A. A. [1 ,4 ]
机构
[1] Russian Acad Sci, PN Lebedev Phys Inst, Leninsky Prosp 53, Moscow 119991, Russia
[2] State Univ, Moscow Inst Phys & Technol, Inst Per 9, Dolgoprudnyi 141701, Moscow Region, Russia
[3] NV Sklifosovsky Res Inst Emergency Med, B Sukharevskaya Pl 3, Moscow 129090, Russia
[4] Natl Res Nucl Univ MEPhI, Kashirskoe Sh 31, Moscow 115409, Russia
关键词
laser-electron X-ray generator; Thomson X-ray generator; laser medicine; angiography; CORONARY-ANGIOGRAPHY;
D O I
10.1070/QEL16208
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We consider a possibility of application of laser-electron X-ray generators for diagnosing the vessel status of internal organs. It is shown that modern lasers and linear accelerators can be used for the development of angiographic instruments of a new type with an increased spatial and temporal resolution while maintaining or reducing the radiation load on the patient and medical staff. Such improvements in diagnostic and ambient factors cannot be achieved with the use of X-ray tubes. All particular estimates and calculations have been performed for a contrast agent based on iodine compounds.
引用
收藏
页码:75 / 78
页数:4
相关论文
共 50 条
[31]   A multi-scale adaptive method for blood vessel enhancement in X-ray angiography [J].
Wu, ZY ;
Fang, M ;
Qian, JZ ;
Schramm, H .
IMAGE PERCEPTION: MEDICAL IMAGING 1997, 1997, 3036 :326-335
[32]   Effect of X-ray contrast media on blood flow properties after coronary angiography [J].
Scheller, B ;
Hennen, B ;
Thünenkötter, T ;
Mrowietz, C ;
Markwirth, T ;
Schieffer, H ;
Jung, F .
THROMBOSIS RESEARCH, 1999, 96 (04) :253-260
[33]   Non-invasive coronary angiography with multi-detector computed tomography: comparison to conventional X-ray angiography [J].
Paul Schoenhagen ;
Arthur E. Stillman ;
Sandy S. Halliburton ;
Stacie A. Kuzmiak ;
Tracy Painter ;
Richard D. White .
The International Journal of Cardiovascular Imaging, 2005, 21 :63-72
[34]   Non-invasive coronary angiography with multi-detector computed tomography: comparison to conventional X-ray angiography [J].
Schoenhagen, P ;
Stillman, AE ;
Halliburton, SS ;
Kuzmiak, SA ;
Painter, T ;
White, RD .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2005, 21 (01) :63-72
[35]   A comparison study between CT angiography with 64-multislice spiral computed tomography and selective X-ray coronary angiography [J].
Cheng, Luyang ;
Jing, Shenhong ;
Zhang, Yina .
EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2013, 5 (03) :969-971
[36]   Analysis of cerebrovascular diseases by a new 3-dimensional computerised X-ray angiography system [J].
Heautot, JF ;
Chabert, E ;
Gandon, Y ;
Croci, S ;
Romeas, R ;
Campagnolo, R ;
Chereul, B ;
Scarabin, JM ;
Carsin, M .
NEURORADIOLOGY, 1998, 40 (04) :203-209
[37]   Spatio-Temporal correspondence attention network for vessel segmentation in X-ray coronary angiography [J].
Gao, Yunlong ;
Ai, Danni ;
Wang, Yuanyuan ;
Cao, Kaibin ;
Song, Hong ;
Fan, Jingfan ;
Xiao, Deqiang ;
Zhang, Tianwei ;
Wang, Yining ;
Yang, Jian .
BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2025, 99
[38]   Automatic gating window selection for gated three-dimensional coronary X-ray angiography [J].
Rasche, V ;
Movassaghi, B ;
Grass, M .
CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 :1050-1054
[39]   First X-ray free optical 3D angiography based on IVOCT and OFDR [J].
Li, Qingrui ;
Ding, Zhenyang ;
Liu, Kun ;
Wang, Huafang ;
Zhu, Rongyang ;
Jiang, Junfeng ;
Liu, Tiegen .
OPTICS AND LASER TECHNOLOGY, 2025, 188
[40]   Implementation of a channelized Hotelling observer model to assess image quality of x-ray angiography systems [J].
Favazza, Christopher P. ;
Fetterly, Kenneth A. ;
Hangiandreou, Nicholas J. ;
Leng, Shuai ;
Schueler, Beth A. .
JOURNAL OF MEDICAL IMAGING, 2015, 2 (01)