Comparative clinical and radiographic outcomes between early and delayed wrist mobilization after volar fixed-angle plate fixation of distal radius fracture

被引:8
|
作者
Laohaprasitiporn, Panai [1 ]
Boonchai, Kitidate [1 ]
Monteerarat, Yuwarat [1 ]
Limthongthang, Roongsak [1 ]
Vathana, Torpon [1 ]
机构
[1] Mahidol Univ, Siriraj Hosp, Fac Med, Dept Orthopaed Surg, Bangkok, Thailand
关键词
LOCKING PLATE; INTERNAL-FIXATION; OPEN REDUCTION; OSTEOSYNTHESIS; REHABILITATION;
D O I
10.1038/s41598-022-13909-4
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Postoperative immobilization protocols after volar fixed-angle plate fixation of distal radius fractures (DRF) vary among surgeons. This study aimed to compare functional outcomes, radiographic parameters, and complications between early and delayed mobilization after volar fixed-angle plate fixation of DRF. This study is a randomized controlled trial. The early group was allowed to perform wrist motion exercise immediately after surgery and the delayed group was allowed to perform it after 2 weeks of external immobilization. Postoperative patient-rated wrist evaluation (PRWE), disabilities of arm, shoulder, and hand (DASH), wrist range of motion, visual analog scale (VAS) pain score, and grip strength were evaluated. Forty-eight patients with DRF were enrolled and randomly allocated to the early or delayed mobilization groups. The PRWE, DASH, VAS pain score, grip strength, and wrist motion of both groups significantly improved over time. However, there were no significant differences between groups at any timepoint. Radiographic parameters were not different between groups. There were no significant differences in functional outcomes, radiographic parameters, and complications between early and delayed mobilization after volar fixed-angle plate of DRF. Immediate postoperative wrist range-of-motion exercise can be safely initiated after volar fixed-angle plate fixation of DRF without external immobilization.
引用
收藏
页数:9
相关论文
共 32 条
  • [1] Multidirectional palmar fixed-angle plate fixation for unstable distal radius fracture
    Mehling, I.
    Meier, M.
    Schloer, U.
    Krimmer, H.
    HANDCHIRURGIE MIKROCHIRURGIE PLASTISCHE CHIRURGIE, 2007, 39 (01) : 29 - 33
  • [2] The effects of a displaced dorsal rim fracture on outcomes after volar plate fixation of a distal radius fracture
    Kim, Jae Kwang
    Cho, Sung Whan
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2012, 43 (02): : 143 - 146
  • [3] Distal radius fractures with diaphyseal involvement: Fixation with fixed angle volar plate
    Rampoldi M.
    Palombi D.
    Tagliente D.
    Journal of Orthopaedics and Traumatology, 2011, 12 (3) : 137 - 143
  • [4] Breakage of a volar locking plate after delayed union of a distal radius fracture
    De Baere, Tom
    Lecouvet, Frederic
    Barbier, Olivier
    ACTA ORTHOPAEDICA BELGICA, 2007, 73 (06): : 785 - 790
  • [5] Use of Volar Locking Plate Versus Intramedullary Nailing for Fixation of Distal Radius Fractures: A Retrospective Analysis of Clinical and Radiographic Outcomes
    Calbiyik, Murat
    Ipek, Deniz
    MEDICAL SCIENCE MONITOR, 2018, 24 : 602 - 613
  • [6] Is early mobilization after volar locking plate fixation in distal radius fractures really beneficial? A meta-analysis of prospective randomized studies
    Lee, Jun-Ku
    Yoon, Byung -Ho
    Kim, Byungsoo
    Ha, Cheungsoo
    Kil, Minkyu
    Shon, Jeong In
    Lee, Hyun Il
    JOURNAL OF HAND THERAPY, 2023, 36 (01) : 196 - 207
  • [7] Fracture of the Distal Radius: Risk Factors for Complications After Locked Volar Plate Fixation
    Soong, Maximillian
    van Leerdam, Roderick
    Guitton, Thierry G.
    Got, Christopher
    Katarincic, Julia
    Ring, David
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2011, 36A (01): : 3 - 9
  • [8] A comparative study protocol of external fixation versus volar plate in treating distal radius fracture
    Zhang, Fuqiang
    Yang, Yang
    Zhang, Hui
    Luo, Xiangli
    MEDICINE, 2020, 99 (50) : E23231
  • [9] Palmar multidirectional fixed-angle plate fixation in distal radius fractures: do intraarticular fractures have a worse outcome than extraarticular fractures?
    Sonderegger, Juerg
    Schindele, S.
    Rau, M.
    Gruenert, J. G.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2010, 130 (10) : 1263 - 1268
  • [10] Clinical and radiologic factors affecting functional outcomes after volar locking plate fixation of dorsal angulated distal radius fractures
    Lee, Seoung-Joon
    Park, Jong Woong
    Kang, Byeong Jik
    Lee, Jung Il
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2016, 21 (05) : 619 - 624