摘要
The kinetic analysis of secondary glow peaks in carbon-doped aluminium oxide is reported. A glow curve measured at 0.4 degrees C s(-1) after beta irradiation to 3 Gy revealed at least five peaks as a result of various techniques of glow curve resolution; the dominant peak at 156 degrees C (peak II) and two weaker-intensity secondary peaks one at 36 degrees C (peak I) and the other at 264 degrees C (peak III). Peaks HA and IV at 170 and 422 degrees C respectively only became apparent after removal of preceding more prominent peaks. The secondary peaks are particularly weak in intensity and are as usual dominated by the main dosimetry peak. The analysis in this report focusses on peak III, usually seen adjacent to the main dosimetry peak but whose presence is masked by the extreme sensitivity of the latter. Complementary analyses of the weaker intensity peaks I, HA and IV are included. Peaks I, HA and HI are subject to first-order kinetics while for peaks II and IV the issue is less conclusive. The activation energy increases from 0.72 eV for peak I to about 1.3 eV for peak IV with values for peak II and HA similar at similar to 1 eV. In general, the frequency factor corresponding to the lower temperature peaks (I, II, and HA) have values (10(10)-10(12) s(-1)) that are an order of magnitude or so greater than for peaks III and IV (10(9)-10(11) s(-1)). Except for peak I, peak H and all other secondary peaks are affected by thermal quenching whose activation energy was determined as Delta E = 0.95 +/- 0.04 eV using peak IIA and as Delta E = 1.48 +/- 0.10 eV using peak III. The overall conclusion is that all peaks correspond to electron traps and are associated with the same recombination centre. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:21 / 30
页数:10
相关论文
共 50 条
  • [1] Concerning secondary thermoluminescence peaks in α-Al2O3:C
    Chithambo, ML
    SOUTH AFRICAN JOURNAL OF SCIENCE, 2004, 100 (11-12) : 524 - 527
  • [2] Comprehensive kinetic analysis of thermoluminescence peaks of α-Al2O3:C,Mg
    Kalita, J. M.
    Chithambo, M. L.
    JOURNAL OF LUMINESCENCE, 2017, 185 : 72 - 82
  • [3] Thermoluminescence of α-Al2O3:C,Mg: Kinetic analysis of the main glow peak
    Kalita, J. M.
    Chithambo, M. L.
    JOURNAL OF LUMINESCENCE, 2017, 182 : 177 - 182
  • [4] Kinetic analysis of the main thermoluminescence glow peak in α-Al2O3
    Espitia, Yulissa
    Cogollo, Rafael
    Osorio, Amalia
    Gutierrez, Omar D.
    RADIATION MEASUREMENTS, 2022, 153
  • [5] Superlinear dose dependence of high temperature thermoluminescence peaks in Al2O3:C
    Lo, D.
    Lawless, J. L.
    Chen, R.
    RADIATION PROTECTION DOSIMETRY, 2006, 119 (1-4) : 71 - 74
  • [6] Influence of the irradiation temperature on the dosimetric and high temperature TL peaks of Al2O3:C
    Molnar, G
    Benabdesselam, M
    Borossay, J
    Iacconi, P
    Lapraz, D
    Akselrod, M
    SOLID STATE DOSIMETRY, PTS 1 AND 2, PROCEEDINGS, 2002, : 139 - 142
  • [7] Influence of the irradiation temperature on the dosimetric and high temperature TL peaks of Al2O3:C
    Molnar, G
    Benabdesselam, M
    Borossay, J
    Iacconi, P
    Lapraz, D
    Akselrod, M
    RADIATION PROTECTION DOSIMETRY, 2002, 100 (1-4) : 139 - 142
  • [8] The influence of dose on the kinetic parameters and dosimetric features of the main thermoluminescence glow peak in α-Al2O3:C,Mg
    Kalita, J. M.
    Chithambo, M. L.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2017, 394 : 12 - 19
  • [9] The kinetic parameters of the main thermoluminescence glow peak of Al2O3:C,Mg: A critical evaluation of different analytical methods
    Munoz, J. M.
    Yoshimura, E. M.
    Chithambo, M. L.
    Jacobsohn, L. G.
    Trindade, N. M.
    JOURNAL OF LUMINESCENCE, 2022, 247
  • [10] Thermoluminescence and radioluminescence of α-Al2O3:C,Mg at high temperatures
    Trindade, Neilo Marcos
    Jacobsohn, Luiz Gustavo
    JOURNAL OF LUMINESCENCE, 2018, 204 : 598 - 602