Full-scale experiment on smoke propagation in metro station tunnel fire under opening the platform screen doors

被引:19
|
作者
Qiu, Peiyun [1 ,2 ,3 ]
Long, Zeng [1 ]
Liu, Chang [1 ]
Yang, Yuxuan [1 ]
Tian, Xiangliang [1 ]
Zhong, Maohua [1 ]
机构
[1] Tsinghua Univ, Dept Engn Phys, Inst Publ Safety Res, Beijing 100084, Peoples R China
[2] Beijing Key Lab City Integrated Emergency Respons, Beijing 100084, Peoples R China
[3] Guangzhou Metro Grp Co LTD, Guangzhou 510330, Guangdong, Peoples R China
基金
中国国家自然科学基金; 国家重点研发计划;
关键词
Full-scale experiment; Fire; Smoke propagation; Station tunnel; Platform screen doors;
D O I
10.1016/j.tust.2020.103662
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The study conducted full-scale fire experiments in a representative subway station tunnel to investigate the law of smoke propagation, and three typical ventilation conditions were designed. Under opening the platform screen doors (PSD), the fuel pan was placed at the centerline of the tunnel, and the temperature profile was measured by a series of thermocouples. The vertical temperature distribution, longitudinal temperature distribution and smoke layer height were analyzed based on the measured data in the field. The results showed that the fire-induced smoke propagation was affected significantly by the longitudinal airflow. Under the natural ventilation, the temperature near the fire region was relatively low, and the smoke layer height varied slightly with the distance. Under the mechanical ventilation, the over track exhaust (OTE) system was activated by default, and the mode of the tunnel ventilation fan (TVF) system was changed. When the TVF system in the mode of supply in the A-end and exhaust in the B-end, the smoke distributed within the range of X = 38.5 to 5.5 m. At the location of X = 38.5 m, the smoke layer height was approximately 2 m, which had an impact on the evacuation. When the TVF system in the mode of exhaust at both ends, the smoke gathered at both ends of tunnel, with the smoke layer height of 4.7 m. Therefore, the third ventilation condition performed better owing to its more stable smoke layer and lower temperature. The conclusions from the full-scale fire experiments could provide on-site data for the emergency response during fire accident in metro station tunnels.
引用
收藏
页数:8
相关论文
共 34 条
  • [31] Investigation on the Performance of Fire Detection Systems for Tunnel Applications - Part 2: Full-Scale Experiments Under Longitudinal Airflow Conditions
    Liu, Z. G.
    Kashef, A. H.
    Lougheed, G. D.
    Crampton, G. P.
    FIRE TECHNOLOGY, 2011, 47 (01) : 191 - 220
  • [32] Investigation on the Performance of Fire Detection Systems for Tunnel Applications––Part 2: Full-Scale Experiments Under Longitudinal Airflow Conditions
    Z. G. Liu
    A. H. Kashef
    G. D. Lougheed
    G. P. Crampton
    Fire Technology, 2011, 47 : 191 - 220
  • [33] Full-scale experiment on the bearing and deformation characteristics for prestressed double-layered shield tunnel linings under high internal pressure
    Tang, Xinwei
    Mai, Shengwen
    Song, Danqing
    Yan, Zhenrui
    Yin, Xiaohong
    INTERNATIONAL JOURNAL OF PRESSURE VESSELS AND PIPING, 2024, 210
  • [34] Physical and mechanical response of large-diameter shield tunnel lining structure under non-uniform fire: A full-scale fire test-based study
    Jin, Da-Long
    Jin, Hui
    Yuan, Da-Jun
    Cheng, Pan-Pan
    Pan, Dong
    UNDERGROUND SPACE, 2025, 20 : 1 - 16