The reliability of electromechanical delay and torque during isometric and concentric isokinetic contractions

被引:38
|
作者
Howatson, Glyn [1 ]
Glaister, Mark [1 ]
Brouner, James [1 ]
van Someren, Ken A. [1 ]
机构
[1] Kingston Univ, Sch Life Sci, Kingston upon Thames KT1 2EE, Surrey, England
关键词
Repeatability; Coefficient of variation; Electromyography; Isokinetic dynamometry; UNFAMILIARISED SUBJECTS; ELECTROMYOGRAPHY; MUSCLE; REPRODUCIBILITY; DYNAMOMETRY; PERFORMANCE;
D O I
10.1016/j.jelekin.2008.02.002
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The purpose of this investigation was to examine the intra-subject reliability of electromechanical delay (EMD) and torque of the dominant and non-dominant elbow flexors during isometric and isokinetic muscle contractions repeated over five consecutive days. Eleven volunteers that were unfamiliar with isokinetic dynamometry participated in this study and were asked to attend the laboratory on five consecutive days. An isokinetic dynamometer was used to exercise the elbow flexors under isometric, slow (60 degrees s(-1)) and fast (210 degrees s(-1)) isokinetic conditions; surface electromyography was recorded from the belly of biceps brachii and the signal was synchronised with the dynamometer to determine EMD. Intra-subject reliability for all measures was good (CV range, 3.1-6.5%) with no discernable difference between the dominant and non-dominant arms during isometric and isokinetic conditions. In addition, there was little difference in EMD and torque variability between the dominant and non-dominant arms which may have applications for clinicians and future research design when monitoring and investigating human muscle function. These data provide researchers and clinicians with an indication of the magnitude of change that is required to elucidate the presence of a meaningful change to muscle function in the elbow flexors. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:975 / 979
页数:5
相关论文
共 50 条
  • [21] Reliability of electromyographic and torque measures during isometric axial rotation exertions of the trunk
    Ng, JKF
    Parnianpour, M
    Kippers, V
    Richardson, CA
    CLINICAL NEUROPHYSIOLOGY, 2003, 114 (12) : 2355 - 2361
  • [22] Effects of repetitive dynamic contractions upon electromechanical delay
    David A. Gabriel
    Jean P. Boucher
    European Journal of Applied Physiology and Occupational Physiology, 1998, 79 : 37 - 40
  • [23] Effects of repetitive dynamic contractions upon electromechanical delay
    Gabriel, DA
    Boucher, JP
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1998, 79 (01) : 37 - 40
  • [24] Neck Muscle EMG-Force Relationship and Its Reliability During Isometric Contractions
    Lo Martire R.
    Gladh K.
    Westman A.
    Äng B.O.
    Sports Medicine - Open, 2017, 3 (1)
  • [25] Plyometric training improves voluntary activation and strength during isometric, concentric and eccentric contractions
    Behrens, Martin
    Mau-Moeller, Anett
    Mueller, Karoline
    Heise, Sandra
    Gube, Martin
    Beuster, Nico
    Herlyn, Philipp K. E.
    Fischer, Dagmar-C.
    Bruhn, Sven
    JOURNAL OF SCIENCE AND MEDICINE IN SPORT, 2016, 19 (02) : 170 - 176
  • [26] Potentiation of isokinetic torque is velocity-dependent following an isometric conditioning contraction
    Fukutani, Atsuki
    Miyamoto, Naokazu
    Kanehisa, Hiroaki
    Yanai, Toshimasa
    Kawakami, Yasuo
    SPRINGERPLUS, 2013, 2 : 1 - 10
  • [27] Reliability of isokinetic dynamometer for isometric assessment of ankle plantar flexor strength
    Santy, Fanny-May
    Pernoud, Anthony
    Barrue-Belou, Simon
    Fourchet, Francois
    Bothorel, Hugo
    Samozino, Pierre
    PHYSICAL THERAPY IN SPORT, 2025, 71 : 36 - 42
  • [28] Muscle fatigue during concentric and eccentric contractions
    Pasquet, B
    Carpentier, A
    Duchateau, J
    Hainaut, K
    MUSCLE & NERVE, 2000, 23 (11) : 1727 - 1735
  • [29] Fatigue reduces the complexity of knee extensor torque during fatiguing sustained isometric contractions
    Pethick, Jamie
    Winter, Samantha L.
    Burnley, Mark
    EUROPEAN JOURNAL OF SPORT SCIENCE, 2019, 19 (10) : 1349 - 1358
  • [30] Reliability of torque measurements during passive isokinetic knee movements in healthy subjects
    Nuyens, G
    De Weerdt, W
    Spaepen, A
    Janssens, L
    Ketelaer, P
    Bogaerts, K
    SCANDINAVIAN JOURNAL OF REHABILITATION MEDICINE, 2000, 32 (02): : 61 - 65