The reliability of electromechanical delay and torque during isometric and concentric isokinetic contractions

被引:38
|
作者
Howatson, Glyn [1 ]
Glaister, Mark [1 ]
Brouner, James [1 ]
van Someren, Ken A. [1 ]
机构
[1] Kingston Univ, Sch Life Sci, Kingston upon Thames KT1 2EE, Surrey, England
关键词
Repeatability; Coefficient of variation; Electromyography; Isokinetic dynamometry; UNFAMILIARISED SUBJECTS; ELECTROMYOGRAPHY; MUSCLE; REPRODUCIBILITY; DYNAMOMETRY; PERFORMANCE;
D O I
10.1016/j.jelekin.2008.02.002
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The purpose of this investigation was to examine the intra-subject reliability of electromechanical delay (EMD) and torque of the dominant and non-dominant elbow flexors during isometric and isokinetic muscle contractions repeated over five consecutive days. Eleven volunteers that were unfamiliar with isokinetic dynamometry participated in this study and were asked to attend the laboratory on five consecutive days. An isokinetic dynamometer was used to exercise the elbow flexors under isometric, slow (60 degrees s(-1)) and fast (210 degrees s(-1)) isokinetic conditions; surface electromyography was recorded from the belly of biceps brachii and the signal was synchronised with the dynamometer to determine EMD. Intra-subject reliability for all measures was good (CV range, 3.1-6.5%) with no discernable difference between the dominant and non-dominant arms during isometric and isokinetic conditions. In addition, there was little difference in EMD and torque variability between the dominant and non-dominant arms which may have applications for clinicians and future research design when monitoring and investigating human muscle function. These data provide researchers and clinicians with an indication of the magnitude of change that is required to elucidate the presence of a meaningful change to muscle function in the elbow flexors. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:975 / 979
页数:5
相关论文
共 50 条
  • [1] EFFECTS OF TRAINING USING ISOKINETIC-CONCENTRIC, ISOKINETIC-ECCENTRIC, AND ISOMETRIC CONTRACTIONS ON THE PEAK TORQUE OF THE KNEE EXTENSORS
    NICELY, K
    SCHULTZ, C
    PORTER, S
    ALLEN, F
    HANTEN, W
    PHYSICAL THERAPY, 1988, 68 (05): : 799 - 799
  • [2] ELECTROMECHANICAL DELAY IN THE VASTUS LATERALIS MUSCLE DURING DYNAMIC ISOMETRIC CONTRACTIONS
    VOS, EJ
    MULLENDER, MG
    SCHENAU, GJ
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1990, 60 (06): : 467 - 471
  • [3] Reliability of electromyography and peak torque during maximum voluntary concentric, isometric and eccentric contractions of quadriceps muscles in healthy subjects
    Carvalho, A.
    Abade, E.
    Carvalho, C.
    Sampaio, J.
    MEDICINA DELLO SPORT, 2014, 67 (02) : 185 - 193
  • [4] Maximal voluntary eccentric, isometric and concentric torque recovery following a concentric isokinetic exercise
    Michaut, A
    Pousson, M
    Millet, G
    Belleville, J
    Van Hoecke, J
    INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2003, 24 (01) : 51 - 56
  • [5] Relaxation electromechanical delay as a fatigue index in isokinetic concentric movement
    Leung, SCS
    Xiao, SJ
    PROCEEDINGS OF THE 19TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 19, PTS 1-6: MAGNIFICENT MILESTONES AND EMERGING OPPORTUNITIES IN MEDICAL ENGINEERING, 1997, 19 : 1286 - 1288
  • [6] EFFECT OF STABILIZATION ON MAXIMAL ISOKINETIC TORQUE OF THE QUADRICEPS FEMORIS MUSCLE DURING CONCENTRIC AND ECCENTRIC CONTRACTIONS
    HANTEN, WP
    RAMBERG, CL
    PHYSICAL THERAPY, 1988, 68 (02): : 219 - 222
  • [7] The effects of three days of concentric isokinetic training on isometric and concentric torque production of the forearm flexors in males
    Traylor, Daniel A.
    Housh, Terry J.
    Camic, Clayton L.
    Zuniga, Jorge M.
    Bergstrom, Haley C.
    Johnson, Glen O.
    Schmidt, Richard J.
    Lewis, Robert W., Jr.
    ISOKINETICS AND EXERCISE SCIENCE, 2013, 21 (01) : 63 - 68
  • [8] Reliability of concentric and eccentric torque during isokinetic knee extension in post-stroke hemiparesis
    Clark, DJ
    Condliffe, EG
    Patten, C
    CLINICAL BIOMECHANICS, 2006, 21 (04) : 395 - 404
  • [9] Reliability of isometric and isokinetic trunk flexor strength using a functional electromechanical dynamometer
    Rodriguez-Perea, Angela
    Chirosa Rios, Luis J.
    Martinez-Garcia, Dario
    Ulloa-Diaz, David
    Rojas, Francisco Guede
    Jerez-Mayorga, Daniel
    Chirosa Rios, Ignacio J.
    PEERJ, 2019, 7
  • [10] TORQUE CURVES PRODUCED AT THE KNEE DURING ISOMETRIC AND ISOKINETIC EXERCISE
    SCUDDER, GN
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1980, 61 (02): : 68 - 73