Influence of digital clubbing on oxygen saturation measurements by pulse-oximetry in cystic fibrosis patients

被引:10
|
作者
Van Ginderdeuren, Filip
Van Cauwelaert, Karlien
Malfroot, Anne
机构
[1] Free Univ Brussels, Akad Ziekenhuis, Dept Physiotherapy, B-1090 Brussels, Belgium
[2] Vrije Univ Brussels, Acad Ziekenhuis, Dept Paediat, Paediat Resp Med & Cyst Fibrosis Clin, Brussels, Belgium
关键词
digital clubbing; arterial oxygen saturation; pulse-oximetry (SpO(2)); cystic fibrosis;
D O I
10.1016/j.jcf.2006.01.007
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Objective: To determine the influence of digital clubbing on oxygen saturation by pulse oximetry measurements (SpO(2)) in Cystic Fibrosis patients. Background: Measuring the arterial oxygen saturation at the fingertip by pulse-oximetry is commonly used in the management of CF patients. In these patients, clinical signs of hyperoxia are often observed with oxygen supplies based on digital oximetry readings. This suggests inaccuracies in the digital measurement method, which in its turn may be caused by digital clubbing. In order to study the influence of digital clubbing, measurements between fingertip and forehead sensor were compared in a clubbing and non-clubbing CF-population. The ear sensor measurements are used as a reference variable. Methods: Two groups were examined. Group I consisted of 50 CF patients without digital clubbing (DPD/IPD ratio< 1.00). Group 2 consisted of 50 CF patients with digital clubbing (DPD / IPD ratio> 1.00). Patients were measured at rest before any treatment and with their daily oxygen supply, if applicable. Saturation was simultaneously measured with three Criticare SpO(2) T pulse oximeters, using a fingertip sensor at the right index (transmission oximetry), a forehead sensor at the forehead (reflectance oximetry) and an ear sensor at the right ear. Results: Using the Bland and Altman method no clear difference was found between the saturation measurements of right ear versus forehead sensor in the two groups. When the measurements of right ear versus fingertip sensor are compared there is still no difference for the non-clubbing group. On the contrary, for the clubbing group lower saturation scores were measured by the fingertip probe compared to the right ear measurement. The differences in saturation became greater as the saturation value at fingertip was lower. Conclusion: Digital clubbing significantly influences the registrations of the SpO(2) measurements by means of a fingertip probe, underestimating the saturation. It can be advised to use the ear sensor as good alternative for these patients. (C) 2006 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:125 / 128
页数:4
相关论文
共 50 条
  • [31] Utility Of Nocturnal Pulse-Oximetry In Detecting Obstructive Sleep Apnea In Hospitalized Patients
    Kahn, D. A.
    Keith, S.
    Mather, P.
    Rubin, S.
    Reeves, G.
    Bonita, R.
    Resnick, L.
    Malloy, C.
    Hasan, N.
    Sharma, S.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2014, 189
  • [32] Effect of nail polish on oxygen saturation determined by pulse oximetry in critically ill patients
    Hinkelbein, Jochen
    Genzwuerker, Harald V.
    Sogl, Reiner
    Fiedler, Fritz
    RESUSCITATION, 2007, 72 (01) : 82 - 91
  • [33] FETAL OXYGEN-SATURATION MEASUREMENT BY TRANSMISSION PULSE OXIMETRY
    BUSCHMANN, J
    RALL, G
    KNITZA, R
    LANCET, 1992, 339 (8793): : 615 - 615
  • [34] Blood haemoglobin and pulse oximetry oxygen saturation measurement error
    Crooks, C.
    West, J.
    Morling, J.
    Simmonds, M.
    Juurlink, I.
    Briggs, S.
    Cruickshank, S.
    Hammond-Pears, S.
    Shaw, D.
    Card, T.
    Fogarty, A.
    EUROPEAN RESPIRATORY JOURNAL, 2022, 60
  • [35] TIME TO EQUILIBRATION OF OXYGEN-SATURATION USING PULSE OXIMETRY
    GRUBER, P
    KWIATKOWSKI, T
    SILVERMAN, R
    FLASTER, E
    AUERBACH, C
    ACADEMIC EMERGENCY MEDICINE, 1995, 2 (09) : 810 - 815
  • [36] BIOLOGICAL QUALITY CONTROL FOR PULSE OXIMETRY OXYGEN SATURATION MEASUREMENT
    Back, Geraldine M.
    Dooney, Natalie A.
    Robiony-Rogers, David
    RESPIROLOGY, 2012, 17 : 7 - 7
  • [37] CONTINUOUS MONITORING OF FETAL OXYGEN-SATURATION BY PULSE OXIMETRY
    LUTTKUS, A
    FENGLER, TW
    FRIEDMANN, W
    DUDENHAUSEN, JW
    OBSTETRICS AND GYNECOLOGY, 1995, 85 (02): : 183 - 186
  • [38] MONITORING OF ARTERIAL OXYGEN-SATURATION BY PULSE OXIMETRY - COMMENT
    SALEM, CJ
    JANDA, A
    BERGER, M
    BRANDSTETTER, A
    ANASTHESIOLOGIE & INTENSIVMEDIZIN, 1988, 29 (10): : 293 - 293
  • [39] Extracorporeal Membrane Oxygenation Physiological Factors Influence Pulse Oximetry and Arterial Oxygen Saturation Discrepancies
    Kalra, Andrew
    Shou, Benjamin L.
    Zhao, David
    Wilcox, Christopher
    Keller, Steven P.
    Kim, Bo Soo
    Whitman, Glenn J. R.
    Cho, Sung-Min
    ANNALS OF THORACIC SURGERY, 2024, 117 (06): : 1221 - 1228
  • [40] Pulse oximetry saturation can predict prognosis of idiopathic pulmonary fibrosis
    Takei, Reoto
    Yamano, Yasuhiko
    Kataoka, Kensuke
    Yokoyama, Toshiki
    Matsuda, Toshiaki
    Kimura, Tomoki
    Furukawa, Taiki
    Takahashi, Osamu
    Chiba, Hirofumi
    Takahashi, Hiroki
    Kondoh, Yasuhiro
    RESPIRATORY INVESTIGATION, 2020, 58 (03) : 190 - 195