Influence of digital clubbing on oxygen saturation measurements by pulse-oximetry in cystic fibrosis patients

被引:10
|
作者
Van Ginderdeuren, Filip
Van Cauwelaert, Karlien
Malfroot, Anne
机构
[1] Free Univ Brussels, Akad Ziekenhuis, Dept Physiotherapy, B-1090 Brussels, Belgium
[2] Vrije Univ Brussels, Acad Ziekenhuis, Dept Paediat, Paediat Resp Med & Cyst Fibrosis Clin, Brussels, Belgium
关键词
digital clubbing; arterial oxygen saturation; pulse-oximetry (SpO(2)); cystic fibrosis;
D O I
10.1016/j.jcf.2006.01.007
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Objective: To determine the influence of digital clubbing on oxygen saturation by pulse oximetry measurements (SpO(2)) in Cystic Fibrosis patients. Background: Measuring the arterial oxygen saturation at the fingertip by pulse-oximetry is commonly used in the management of CF patients. In these patients, clinical signs of hyperoxia are often observed with oxygen supplies based on digital oximetry readings. This suggests inaccuracies in the digital measurement method, which in its turn may be caused by digital clubbing. In order to study the influence of digital clubbing, measurements between fingertip and forehead sensor were compared in a clubbing and non-clubbing CF-population. The ear sensor measurements are used as a reference variable. Methods: Two groups were examined. Group I consisted of 50 CF patients without digital clubbing (DPD/IPD ratio< 1.00). Group 2 consisted of 50 CF patients with digital clubbing (DPD / IPD ratio> 1.00). Patients were measured at rest before any treatment and with their daily oxygen supply, if applicable. Saturation was simultaneously measured with three Criticare SpO(2) T pulse oximeters, using a fingertip sensor at the right index (transmission oximetry), a forehead sensor at the forehead (reflectance oximetry) and an ear sensor at the right ear. Results: Using the Bland and Altman method no clear difference was found between the saturation measurements of right ear versus forehead sensor in the two groups. When the measurements of right ear versus fingertip sensor are compared there is still no difference for the non-clubbing group. On the contrary, for the clubbing group lower saturation scores were measured by the fingertip probe compared to the right ear measurement. The differences in saturation became greater as the saturation value at fingertip was lower. Conclusion: Digital clubbing significantly influences the registrations of the SpO(2) measurements by means of a fingertip probe, underestimating the saturation. It can be advised to use the ear sensor as good alternative for these patients. (C) 2006 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:125 / 128
页数:4
相关论文
共 50 条
  • [21] Accuracy of two pulse-oximetry measurements for INTELLiVENT-ASV in mechanically ventilated patients: a prospective observational study
    Shinshu Katayama
    Jun Shima
    Ken Tonai
    Kansuke Koyama
    Shin Nunomiya
    Scientific Reports, 11
  • [22] Accuracy of two pulse-oximetry measurements for INTELLiVENT-ASV in mechanically ventilated patients: a prospective observational study
    Katayama, Shinshu
    Shima, Jun
    Tonai, Ken
    Koyama, Kansuke
    Nunomiya, Shin
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [23] THE EFFECT OF DYSHEMOGLOBINEMIA (METHEMOGLOBINEMIA) ON THE ACCURACY OF MEASUREMENTS MADE BY PULSE-OXIMETRY DURING LENGTHY SURGERY
    MICHAELIS, G
    BISCOPING, J
    HEMPELMANN, G
    ANAESTHESIST, 1988, 37 (11): : 731 - 731
  • [24] Arterial Oxygen Saturation, Pulse Oximetry, and Cerebral and Tissue Oximetry in Hypobaric Hypoxia
    Ottestad, William
    Kasin, Jan Ivar
    Hoiseth, Lars Oivind
    AEROSPACE MEDICINE AND HUMAN PERFORMANCE, 2018, 89 (12) : 1045 - 1049
  • [25] Baseline oxigen saturation obtained by pulse-oximetry and diagnosis of heart failure in the acute phase of myocardial infarction
    Masip, J
    Vecilla, F
    Gayà, M
    Páez, J
    Betbesé, A
    Manresa, R
    Padró, J
    Cañizares, R
    EUROPEAN HEART JOURNAL, 2002, 23 : 226 - 226
  • [26] Digital clubbing in cystic fibrosis: The nails as clues to advanced disease Response
    Smith, Aaron D.
    Schwartzman, Gabrielle
    Lyons, Catherine E.
    Flowers, Hal
    Albon, Dana
    Greer, Kenneth
    Lonabaugh, Kevin
    Zlotoff, Barrett J.
    JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 2024, 91 (05) : e135 - e135
  • [27] Inaccurate pulse CO-oximetry of carboxyhemoglobin due to digital clubbing: case report
    Harlan, Nicole
    Weaver, Lindell K.
    Deru, Kayla
    UNDERSEA AND HYPERBARIC MEDICINE, 2016, 43 (01) : 59 - 61
  • [28] Exercise-induced changes of oxygen saturation in patients with cystic fibrosis
    Stern, M
    Strauss, H
    MONATSSCHRIFT KINDERHEILKUNDE, 1996, 144 (09) : 910 - 917
  • [29] OXYGEN-SATURATION IN CYSTIC-FIBROSIS
    BETANCOURT, M
    SLADE, G
    DINWIDDIE, R
    ARCHIVES OF DISEASE IN CHILDHOOD, 1991, 66 (09) : 1075 - 1076
  • [30] PREDICTING CHANGES IN OXYGEN-SATURATION USING PULSE OXIMETRY
    SAPSFORD, DJ
    JONES, JG
    BRITISH JOURNAL OF ANAESTHESIA, 1988, 61 (04) : P497 - P497