Hyperbaric dye solution distribution characteristics after pencil-point needle injection in a spinal cord model

被引:42
作者
Holman, SJ
Robinson, RA
Beardsley, D
Stewart, SFC
Klein, L
Stevens, RA
机构
[1] UNIFORMED SERV UNIV HLTH SCI, DEPT ANESTHESIOL, BETHESDA, MD 20814 USA
[2] NATL NAVAL MED CTR, DEPT ANESTHESIOL, BETHESDA, MD USA
[3] LOYOLA UNIV, STRITCH SCH MED, MAYWOOD, IL 60153 USA
[4] US FDA, ROCKVILLE, MD 20857 USA
关键词
anesthetic techniques; spinal; pencil point needles; anesthetics; local; lidocaine; complications; neurological; maldistribution;
D O I
10.1097/00000542-199704000-00027
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: The flow-rate limiting and directional characteristics of caudally directed microcatheters, which lead to intrathecal maldistribution of hyperbaric 5% lidocaine, are believed to have contributed to at least 11 cases of cauda equina syndrome, The authors investigated the distribution characteristics of hyperbaric dye solutions via caudally directed side-port needles at various rates of injection in a spinal cord model to determine the potential for maldistribution. Methods: Using a digital video image processing technique, we injected a hyperbaric solution of phthalocyanine blue dye through caudally directed side-port needles into a supinely oriented transparent spinal canal model filled with simulated cerebrospinal fluid. Injections via commonly used spinal needles (24-gauge and 25-gauge Sprotte, and 25-gauge and 27-gauge Whitacre) were recorded using five injection rates (2, 4, 6, 8, and 16 ml/min), Results: For all needles tested, injection rate had a significant effect on the peak dye concentration (P < 0.0001). Injection rates greater than or equal to 6 ml/min (2 ml/20 s) resulted in peak dye concentrations of less than 168 mg/l (extrapolated concentration of 1% lidocaine). Injection via the 24-gauge Sprotte needle, which has a larger orifice area and internal diameter, resulted in significantly lower peak dye concentrations than via the smaller Whitacre needles tested (P < 0.05). Conclusions: Sacral maldistribution could be minimized by using injection rates greater than or equal to 6 ml/min (2 ml/20 s), for all of the side-port spinal needles used in this model study, When very slow injection rates (2 ml/min) are used, peak dye concentrations varied inversely and significantly with needle internal diameter and orifice area.
引用
收藏
页码:966 / 973
页数:8
相关论文
共 33 条
  • [1] *ASTR PHARM PROD, 1993, ASTR COMP REG AN
  • [2] CONCENTRATION-DEPENDENCE OF LIDOCAINE-INDUCED IRREVERSIBLE CONDUCTION LOSS IN FROG NERVE
    BAINTON, CR
    STRICHARTZ, GR
    [J]. ANESTHESIOLOGY, 1994, 81 (03) : 657 - 667
  • [3] TRANSIENT NEUROLOGIC DEFICIT AFTER SPINAL-ANESTHESIA - LOCAL-ANESTHETIC MALDISTRIBUTION WITH PENCIL POINT NEEDLES
    BEARDSLEY, D
    HOLMAN, S
    GANTT, R
    ROBINSON, RA
    LINDSEY, J
    BAZARAL, M
    STEWART, SFC
    STEVENS, RA
    [J]. ANESTHESIA AND ANALGESIA, 1995, 81 (02) : 314 - 320
  • [4] BEARDSLEY DJ, 1996, ANESTH ANALG, V82, pS21
  • [5] CHENG ACK, 1994, ANESTH ANALG, V78, P157
  • [6] DEJONG RH, 1994, ANESTH ANALG, V78, P3
  • [7] CAUDA-EQUINA SYNDROME FOLLOWING INTENDED EPIDURAL-ANESTHESIA
    DRASNER, K
    RIGLER, ML
    SESSLER, DI
    STOLLER, ML
    [J]. ANESTHESIOLOGY, 1992, 77 (03) : 582 - 585
  • [8] PERSISTENT SACRAL SENSORY DEFICIT INDUCED BY INTRATHECAL LOCAL-ANESTHETIC INFUSION IN THE RAT
    DRASNER, K
    SAKURA, S
    CHAN, VWS
    BOLLEN, AW
    CIRIALES, R
    [J]. ANESTHESIOLOGY, 1994, 80 (04) : 847 - 852
  • [9] LONG-TERM FOLLOW-UP OF PATIENTS WHO RECEIVED 10,098 SPINAL ANESTHETICS - FAILURE TO DISCOVER MAJOR NEUROLOGICAL SEQUELAE
    DRIPPS, RD
    VANDAM, LD
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1954, 156 (16): : 1486 - 1491
  • [10] IN-VITRO CHANGES OF OSMOLALITY AND DENSITY OF SPINAL ANESTHETIC SOLUTIONS
    ERNST, EA
    [J]. ANESTHESIOLOGY, 1968, 29 (01) : 104 - &