Beam test results of the US-CMS forward pixel detector

被引:5
作者
Atac, M
Bartz, E
Bolla, G
Bortoletto, D
Chien, CY
Cremaldi, L
Doroshenko, J
Giolo, K
Gobbi, B
Gomez, P
Grim, G
Koeth, T
Kozhevnikov, Y
Lander, R
Malik, S
Pellett, D
Perera, L
Pernicka, M
Rott, C
Roy, A
Sanders, D
Schnetzer, S
Steininger, H
Stone, R
Swartz, M
Tilden, R
Xie, X
机构
[1] Fermilab Natl Accelerator Lab, Batavia, IL 60510 USA
[2] Rutgers State Univ, Piscataway, NJ 08854 USA
[3] Purdue Univ, W Lafayette, IN 47907 USA
[4] Johns Hopkins Univ, Baltimore, MD 21218 USA
[5] Univ Mississippi, University, MS 38677 USA
[6] Northwestern Univ, Evanston, IL 60201 USA
[7] Univ Calif Davis, Davis, CA 95616 USA
[8] Osterr Akad Wissensch, Inst Hochenergiephys, A-1050 Vienna, Austria
基金
美国国家科学基金会;
关键词
CMS; forward; pixel; FPIX; beam test; resolution;
D O I
10.1016/S0168-9002(02)00472-2
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
CMS will use silicon pixel as its innermost tracking device. Prototypes of these 150 mum square pixels bump bonded to DMILL readout chips were tested at CERN in a pion beam. A silicon telescope consisting of 8 planes of silicon strips was used to interpolate tracks to the position of the pixel detector. Data were taken with the beam at different angles of incidence relative to the pixel sensors. Position resolutions between 10 and 20 mum, depending on the hit position, were observed using charge sharing for the final configuration with unirradiated detectors, The observed resolution was as expected. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:271 / 281
页数:11
相关论文
共 7 条
[1]   Diamond pixel detectors [J].
Adam, W ;
Berdermann, E ;
Bergonzo, P ;
Bertuccio, G ;
Bogani, F ;
Borchi, E ;
Brambilla, A ;
Bruzzi, M ;
Colledani, C ;
Conway, J ;
D'Angelo, P ;
Dabrowski, W ;
Delpierre, P ;
Deneuville, A ;
Doroshenko, J ;
Dulinski, W ;
van Eijk, B ;
Fallou, A ;
Fizzotti, F ;
Foster, J ;
Foulon, F ;
Friedl, M ;
Gan, KK ;
Gheeraert, E ;
Gobbi, B ;
Grim, C ;
Hallewell, G ;
Han, S ;
Hartjes, F ;
Hrubec, J ;
Husson, D ;
Kagan, H ;
Kania, D ;
Kaplon, J ;
Kass, R ;
Koeth, T ;
Krammer, M ;
Lander, R ;
Logiudice, A ;
Lu, R ;
mac Lynne, L ;
Manfredotti, C ;
Meier, D ;
Mishina, M ;
Moroni, L ;
Oh, A ;
Pan, LS ;
Pernicka, M ;
Perera, L ;
Pirollo, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 465 (01) :88-91
[2]   Design and test of pixel sensors for the CMS experiment [J].
Bolla, G ;
Bortoletto, D ;
Rott, C ;
Roy, A ;
Kwan, S ;
Chien, CY ;
Cho, H ;
Gobbi, B ;
Horisberger, R ;
Kaufmann, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 461 (1-3) :182-184
[3]  
*CMS COLL, CERNLHC986 CMS COLL
[4]   Readout architectures for Pixel detectors [J].
Horisberger, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 465 (01) :148-152
[5]  
KARPINSKI W, 1999, 5 WORKSH EL LHC EXP
[6]  
1997, US CMS FORWARD PIXEL
[7]  