Methods for validating the performance of wearable motion-sensing devices under controlled conditions

被引:3
作者
Bliley, Kara E. [1 ]
Kaufman, Kenton R. [1 ]
Gilbert, Barry K. [1 ]
机构
[1] Mayo Clin, Dept Physiol & Biomed Engn, Rochester, MN 55905 USA
关键词
accelerometer; acceleration; motion; validation; performance; DAILY PHYSICAL-ACTIVITY; ENERGY-EXPENDITURE; INERTIAL SENSORS; RATE GYROSCOPES; ACCELEROMETERS; ORIENTATION; TRACKING; KINEMATICS; AGREEMENT;
D O I
10.1088/0957-0233/20/4/045802
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper presents validation methods for assessing the accuracy and precision of motion-sensing device (i.e. accelerometer) measurements. The main goals of this paper were to assess the accuracy and precision of these measurements against a gold standard, to determine if differences in manufacturing and assembly significantly affected device performance and to determine if measurement differences due to manufacturing and assembly could be corrected by applying certain post-processing techniques to the measurement data during analysis. In this paper, the validation of a posture and activity detector ( PAD), a device containing a tri-axial accelerometer, is described. Validation of the PAD devices required the design of two test fixtures: a test fixture to position the device in a known orientation, and a test fixture to rotate the device at known velocities and accelerations. Device measurements were compared to these known orientations and accelerations. Several post-processing techniques were utilized in an attempt to reduce variability in the measurement error among the devices. In conclusion, some of the measurement errors due to the inevitable differences in manufacturing and assembly were significantly improved (p < 0.01) by these post-processing techniques.
引用
收藏
页数:13
相关论文
共 21 条
[1]   Validity of four motion sensors in measuring moderate intensity physical activity [J].
Bassett, DR ;
Ainsworth, BE ;
Swartz, AM ;
Strath, SJ ;
O'Brien, WL ;
King, GA .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2000, 32 (09) :S471-S480
[2]  
Beegle R. W., 1999, International Test Conference 1999. Proceedings (IEEE Cat. No.99CH37034), P338, DOI 10.1109/TEST.1999.805648
[3]   Measuring agreement in method comparison studies [J].
Bland, JM ;
Altman, DG .
STATISTICAL METHODS IN MEDICAL RESEARCH, 1999, 8 (02) :135-160
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]  
BLILEY KE, 2007, C P IEEE ENG MED BIO, P2659
[6]   The accuracy of measuring the kinematics of rising from a chair with accelerometers and gyroscopes [J].
Boonstra, MC ;
van der Slikke, RMA ;
Keijsers, NLW ;
van Lummel, RC ;
Malefijt, MCD ;
Verdonschot, N .
JOURNAL OF BIOMECHANICS, 2006, 39 (02) :354-358
[7]   A triaxial accelerometer and portable data processing unit for the assessment of daily physical activity [J].
Bouten, CVC ;
Koekkoek, KTM ;
Verduin, M ;
Kodde, R ;
Janssen, JD .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1997, 44 (03) :136-147
[8]   The technology of accelerometry-based activity monitors: Current and future [J].
Chen, KY ;
Bassett, DR .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2005, 37 (11) :S490-S500
[9]   Pedestrian tracking with shoe-mounted inertial sensors [J].
Foxlin, E .
IEEE COMPUTER GRAPHICS AND APPLICATIONS, 2005, 25 (06) :38-46
[10]   The development and test of a device for the reconstruction of 3-D position and orientation by means of a kinematic sensor assembly with rate gyroscopes and accelerometers [J].
Giansanti, D ;
Maccioni, G ;
Macellari, V .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2005, 52 (07) :1271-1277