Relationship Between Central Corneal Thickness, Refractive Error, Corneal Curvature, Anterior Chamber Depth and Axial Length

被引:70
作者
Chen, Mei-Ju [1 ,2 ]
Liu, Yin-Tzu [1 ]
Tsai, Chia-Chen [2 ,3 ]
Chen, Yen-Cheng [2 ]
Chou, Ching-Kuang [1 ,2 ]
Lee, Shu-Mei [1 ,2 ]
机构
[1] Taipei Vet Gen Hosp, Dept Ophthalmol, Taipei 112, Taiwan
[2] Natl Yang Ming Univ, Sch Med, Taipei 112, Taiwan
[3] Cheng Hsin Gen Hosp, Dept Ophthalmol, Taipei, Taiwan
关键词
anterior chamber depth; axial length; central corneal thickness; corneal curvature; refractive error; INTRAOCULAR-PRESSURE; GLAUCOMA; CHINESE; MYOPIA;
D O I
10.1016/S1726-4901(09)70038-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: To determine the relationship between central corneal thickness (CCT), refractive error, corneal curvature, anterior chamber depth and axial length in normal Taiwanese Chinese adults. Methods: Five hundred normal Taiwanese Chinese patients aged 40-80 years were recruited for the study. Measurement procedures included CCT, refractive error, corneal curvature, anterior chamber depth and axial length. Exclusion criteria were previous ocular surgery, glaucoma, trauma history, external eye disease, and previous contact lens use. The relationships among parameters were tested using Pearson's correlation and linear regression analysis. Results: The median CCT was 555 +/- 27 mu m for males and 553 +/- 30 mu m for females. Eyes with more myopic refractive error tended to have greater axial length (r= -0.645, p < 0.001). Eyes with axial elongation tended to have flatter cornea (r= -0.502, p < 0.001) and deeper anterior chamber (r= 0.651, p < 0.001). There were no significant correlations between the CCT and refractive error (r=-0.034, p=0.445), corneal curvature (r=0.013, p=0.770), anterior chamber depth (r=0.023, p=0.614) and axial length (r=-0.053, p=0.223). Conclusion: CCT was not associated with refractive error, corneal curvature, anterior chamber depth and axial length. CCT is an independent factor unrelated to other ocular parameters. [J Chin Med Assoc 2009;72(3):133-137]
引用
收藏
页码:133 / 137
页数:5
相关论文
共 26 条
[21]   Corneal thickness and axial length [J].
Shimmyo, M ;
Orloff, PN .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2005, 139 (03) :553-554
[22]   Intraocular pressure, Goldmann applanation tension, corneal thickness, and corneal curvature in Caucasians, Asians, Hispanics, and African Americans [J].
Shimmyo, M ;
Ross, AJ ;
Moy, A ;
Mostafavi, R .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2003, 136 (04) :603-+
[23]   Central corneal thickness, tonometry, and ocular dimensions in glaucoma and ocular hypertension [J].
Singh, RP ;
Goldberg, I ;
Graham, SL ;
Sharma, A ;
Mohsin, M .
JOURNAL OF GLAUCOMA, 2001, 10 (03) :206-210
[24]   Corneal thickness in an ophthalmologically normal Japanese population [J].
Suzuki, S ;
Suzuki, Y ;
Iwase, A ;
Araie, M .
OPHTHALMOLOGY, 2005, 112 (08) :1327-1336
[25]   Corneal thickness determination and correlates in Singaporean schoolchildren [J].
Tong, L ;
Saw, SM ;
Siak, JK ;
Gazzard, G ;
Tan, D .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 (11) :4004-4009
[26]   Central corneal thickness in adult Chinese. Association with ocular and general parameters. The Beijing Eye Study [J].
Zhang, Haitao ;
Xu, Liang ;
Chen, Changxi ;
Jonas, Jost B. .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2008, 246 (04) :587-592