Reference Values for Assessing Localized Hand Lymphedema Using Interhand Tissue Dielectric Constant Ratios

被引:12
作者
Mayrovitz, Harvey N. [1 ]
Arzanova, Evelina [1 ]
Somarriba, Scarlett [1 ]
Eisa, Samar [1 ]
机构
[1] Nova Southeastern Univ, Dept Physiol, Coll Med Sci, 3200 S Univ Dr, Ft Lauderdale, FL 33328 USA
关键词
lymphedema; edema; hand; tissue dielectric constant; TDC ratios; TDC thresholds; BREAST-CANCER; BIOIMPEDANCE SPECTROSCOPY; WATER; SKIN; VOLUME; WOMEN; AGE; RELIABILITY; VALIDITY;
D O I
10.1089/lrb.2017.0065
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: Early detection and tracking of breast cancer treatment-related lymphedema have been helped by quantitative assessment methods and parameters, including bioelectrical impedance spectroscopy and tissue dielectric constant (TDC). Such measurements are evaluated with respect to interarm differences or ratios that (when exceeding specified thresholds) are suggestive of lymphedema. Specific threshold ratios depend on the assessment method and have been reported for arms. However, there is far less information available on thresholds to assess lymphedema that manifests in at-risk hands and essentially nothing known about TDC ratios in healthy hands. Such information is essential to establish reference values from which lymphedema threshold TDC values may be estimated. The specific aim of this research was to determine such interhand TDC ratios applicable to both young and mature women. Methods and Results: A total of 70 women (35 under 30 years of age, YOUNG, and 35 over 50 years of age, MATURE) participated after signing an approved institutional review board informed consent. TDC values of the hand dorsum web were measured bilaterally in triplicate with participants in a supine resting position. Results showed MATURE TDC values to be about 15% less than YOUNG (p<0.01) on dominant and nondominant hands, but no statistical difference in dominant/nondominant interarm ratios (1.0260.100). Conclusions: Based on this data set's overall mean and two standard deviation value, an age-independent interhand TDC threshold ratio of 1.23 emerges as potentially useful for lymphedema detection. This is a good initial start threshold that is usable in future clinical and research assessments.
引用
收藏
页码:442 / 445
页数:4
相关论文
共 29 条
  • [1] Noninvasive method for measuring the electrical properties of deep tissues using an open-ended coaxial probe
    Aimoto, A
    Matsumoto, T
    [J]. MEDICAL ENGINEERING & PHYSICS, 1996, 18 (08) : 641 - 646
  • [2] Penetration of electromagnetic fields of an open-ended coaxial probe between 1 MHz and 1 GHz in dielectric skin measurements
    Alanen, E
    Lahtinen, T
    Nuutinen, J
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (07) : N169 - N176
  • [3] Armer Jane M., 2005, Lymphatic Research and Biology, V3, P208, DOI 10.1089/lrb.2005.3.208
  • [4] A Prospective Validation Study of Bioimpedance with Volume Displacement in Early-Stage Breast Cancer Patients at Risk for Lymphedema
    Barrio, Andrea V.
    Eaton, Anne
    Frazier, Thomas G.
    [J]. ANNALS OF SURGICAL ONCOLOGY, 2015, 22 : S370 - S375
  • [5] Reliability and validity of the figure-of-eight method of measuring hand size in patients with breast cancer-related lymphoedema
    Borthwick, Y.
    Paul, L.
    Sneddon, M.
    McAlpine, L.
    Miller, C.
    [J]. EUROPEAN JOURNAL OF CANCER CARE, 2013, 22 (02) : 196 - 201
  • [6] The dielectric properties of biological tissues .2. Measurements in the frequency range 10 Hz to 20 GHz
    Gabriel, S
    Lau, RW
    Gabriel, C
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (11) : 2251 - 2269
  • [7] Experimental and Analytical Comparisons of Tissue Dielectric Constant (TDC) and Bioimpedance Spectroscopy (BIS) in Assessment of Early Arm Lymphedema in Breast Cancer Patients after Axillary Surgery and Radiotherapy
    Lahtinen, Tapani
    Seppala, Jan
    Viren, Tuomas
    Johansson, Karin
    [J]. LYMPHATIC RESEARCH AND BIOLOGY, 2015, 13 (03) : 176 - 185
  • [8] Reliability and Concurrent Validity of the Perometer for Measuring Hand Volume in Women With and Without Lymphedema
    Lee, Mi-Joung
    Boland, Robert A.
    Czerniec, Sharon
    Kilbreath, Sharon L.
    [J]. LYMPHATIC RESEARCH AND BIOLOGY, 2011, 9 (01) : 13 - 18
  • [9] Levenhagen K, 2017, REHABIL ONCOL, V35, pE1, DOI 10.1097/01.REO.0000000000000073
  • [10] Maihafer George C, 2003, J Hand Ther, V16, P305, DOI 10.1197/S0894-1130(03)00155-8