Absolute myocardial perfusion in canines measured by using dual-bolus first-pass MR imaging

被引:221
作者
Christian, TF [1 ]
Rettmann, DW [1 ]
Aletras, AH [1 ]
Liao, SL [1 ]
Taylor, JL [1 ]
Balaban, RS [1 ]
Arai, AE [1 ]
机构
[1] NHLBI, Cardiac Energet Lab, NIH, Dept Hlth & Human Serv, Bethesda, MD 20892 USA
关键词
animals; experimental study; heart; MR; perfusion; magnetic resonance (MR); perfusion study;
D O I
10.1148/radiol.2323030573
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare fluorescent microsphere measurements of myocardial blood flow (MBF) with qualitative, semiquantitative, and fully quantitative measurements of first-pass perfusion at magnetic resonance (MR) imaging. MATERIALS AND METHODS: Coronary artery occlusion or intracoronary adenosine infusion was successfully performed in 16 beagles; both procedures were performed simultaneously in one animal. MBF was assessed at microsphere analysis. First-pass myocardial perfusion MR imaging was performed during a dual-bolus administration of gadopentetate dimeglumine (0.0025 mmol/kg followed by 0.10 mmol/kg). The absolute myocardial perfusion at MR imaging was calculated by using Fermi function deconvolution methods. Qualitative, semiquantitative, and absolute myocardial perfusion MR imaging measurements were compared with microsphere MBF measurements by using paired t tests, linear correlation, and Bland-Altman analysis. RESULTS: Fully quantitative (ie, absolute) analysis of MBF at MR imaging correlated with microsphere MBF measurement (r = 0.95, P <.001) across the full range of blood flow rates encountered (from 0 to >5.0 mL/min/g). Similar close correlations were observed in endocardial and epicardial segments (representing approximately 0.85 g of the myocardium). With modest increases in MBF, qualitative measurements plateaued in the hyperemic zones. Semiquantitative measurements did not correlate with MBF as well (r = 0.69-0.89); they plateaued around 3.0 mL/min/g. CONCLUSION: Dual-bolus MR imaging enabled accurate measurement of absolute epicardial and endocardial perfusion across a wide range of blood flow rates (0 to >5.0 mL/min/g). Use of qualitative MR imaging measures such as the contrast enhancement ratio led to substantially underestimated hyperemic blood flow measurements. (C) RSNA, 2004.
引用
收藏
页码:677 / 684
页数:8
相关论文
共 23 条
  • [1] Noninvasive detection of myocardial ischemia from perfusion reserve based on cardiovascular magnetic resonance
    Al-Saadi, N
    Nagel, E
    Gross, M
    Bornstedt, A
    Schnackenburg, B
    Klein, C
    Klimek, W
    Oswald, H
    Fleck, E
    [J]. CIRCULATION, 2000, 101 (12) : 1379 - 1383
  • [2] TISSUE MEAN TRANSIT-TIME FROM DYNAMIC COMPUTED-TOMOGRAPHY BY A SIMPLE DECONVOLUTION TECHNIQUE
    AXEL, L
    [J]. INVESTIGATIVE RADIOLOGY, 1983, 18 (01) : 94 - 99
  • [3] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [4] REGIONAL TRANSIT-TIME ESTIMATION FROM IMAGE RESIDUE CURVES
    CLOUGH, AV
    ALTINAWI, A
    LINEHAN, JH
    DAWSON, CA
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 1994, 22 (02) : 128 - 143
  • [5] A myocardial perfusion reserve index in humans using first-pass contrast-enhanced magnetic resonance imaging
    Cullen, JHS
    Horsfield, MA
    Reek, CR
    Cherryman, GR
    Barnett, DB
    Samani, NJ
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 33 (05) : 1386 - 1394
  • [6] Improved coverage in dynamic contrast-enhanced cardiac MRI using interleaved gradient-echo EPI
    Ding, SJ
    Wolff, SD
    Epstein, FH
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (04) : 514 - 519
  • [7] TOTAL AND REGIONAL CORONARY BLOOD FLOW MEASURED BY RADIOACTIVE MICROSPHERES IN CONSCIOUS AND ANESTHETIZED DOGS
    DOMENECH, RJ
    HOFFMAN, JIE
    NOBLE, MIM
    SAUNDERS, KB
    HENSON, JR
    SUBIJANTO, S
    [J]. CIRCULATION RESEARCH, 1969, 25 (05) : 581 - +
  • [8] Water diffusion and exchange as they influence contrast enhancement
    Donahue, KM
    Weisskoff, RM
    Burstein, D
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (01): : 102 - 110
  • [9] Multislice first-pass cardiac perfusion MRI: Validation in a model of myocardial infarction
    Epstein, FH
    London, JF
    Peters, DC
    Goncalves, LM
    Agyeman, K
    Taylor, J
    Balaban, RS
    Arai, AE
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (03) : 482 - 491
  • [10] COMPARISON BETWEEN TL-201 AND TC-99M SESTAMIBI UPTAKE DURING ADENOSINE-INDUCED VASODILATION AS A FUNCTION OF CORONARY STENOSIS SEVERITY
    GLOVER, DK
    RUIZ, M
    EDWARDS, NC
    CUNNINGHAM, M
    SIMANIS, JP
    SMITH, WH
    WATSON, DD
    BELLER, GA
    [J]. CIRCULATION, 1995, 91 (03) : 813 - 820