Simultaneous quantitative analysis of metabolites using ion-pair liquid chromatography - Electrospray ionization mass spectrometry

被引:200
作者
Coulier, Leon [1 ]
Bas, Richard [1 ]
Jespersen, Sonja [1 ]
Verheij, Elwin [1 ]
van der Werf, Mariet J. [1 ]
Hankemeier, Thomas [1 ]
机构
[1] TNO Qual Life, Analyt Res Dept, NL-3700 AJ Zeist, Netherlands
关键词
D O I
10.1021/ac0607616
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We have developed an analytical method, consisting of ion-pair liquid chromatography coupled to electrospray ionization mass spectrometry (IP-LC-ESI-MS), for the simultaneous quantitative analysis of several key classes of polar metabolites, like nucleotides, coenzyme A esters, sugar nucleotides, and sugar bisphosphates. The use of the ion-pair agent hexylamine and optimization of the pH of the mobile phases were critical parameters in obtaining good retention and peak shapes of many of the above-mentioned polar and acidic metabolites that are impossible to analyze using standard reversed-phase LC/MS. Optimum conditions were found when using a gradient from 5 mM hexylamine in water ( pH 6.3) to 90% methanol/ 10% 10 mM ammonium acetate ( pH 8.5). The IP-LC-ESI-MS method was extensively validated by determining the linearity (R-2 > 0.995), sensitivity ( limit of detection 0.1-1 ng), repeatability, and reproducibility ( relative standard deviation < 10%). The IP-LC-ESI-MS method was shown to be a useful tool for microbial metabolomics, i.e., the comprehensive quantitative analysis of metabolites in extracts of microorganisms, and for the determination of the energy charge, i.e., the cellular energy status, as an overall quality measure for the sample workup and analytical protocols.
引用
收藏
页码:6573 / 6582
页数:10
相关论文
共 50 条
[41]   Simultaneous quantitative determination method for sphingolipid metabolites by liquid chromatography/ionspray ionization tandem mass spectrometry [J].
Mano, N ;
Oda, Y ;
Yamada, K ;
Asakawa, N ;
Katayama, K .
ANALYTICAL BIOCHEMISTRY, 1997, 244 (02) :291-300
[42]   Ultraperformance liquid chromatography with electrospray ionization ion trap mass spectrometry for chondroitin disaccharide analysis [J].
Solakyildirim, Kemal ;
Zhang, Zhenqing ;
Linhardt, Robert J. .
ANALYTICAL BIOCHEMISTRY, 2010, 397 (01) :24-28
[43]   Analysis of benzphetamine and its metabolites in rat urine by liquid chromatography-electrospray ionization mass spectrometry [J].
Sato, M ;
Mitsui, T ;
Nagase, H .
JOURNAL OF CHROMATOGRAPHY B, 2001, 751 (02) :277-289
[45]   Electrospray ionization mass spectrometry coupled to reversed-phase ion-pair high-performance liquid chromatography for quantitation of sodium borocaptate and application to pharmacokinetic analysis [J].
Gibson, CR ;
Staubus, AE ;
Barth, RF ;
Yang, WL ;
Kleinholz, NM ;
Jones, RB ;
Green-Church, KB ;
Tjarks, W ;
Soloway, AH .
ANALYTICAL CHEMISTRY, 2002, 74 (10) :2394-2399
[46]   Analysis of biofluids for flunitrazepam and metabolites by electrospray liquid chromatography/mass spectrometry [J].
LeBeau, MA ;
Montgomery, MA ;
Wagner, JR ;
Miller, ML .
JOURNAL OF FORENSIC SCIENCES, 2000, 45 (05) :1133-1141
[47]   Simultaneous analysis of twenty free amino acids in tobacco using liquid chromatography-electrospray ionization/ion trap tandem mass spectrometry [J].
Huang Yifei ;
Hu Jing .
CHINESE JOURNAL OF CHROMATOGRAPHY, 2010, 28 (06) :615-622
[48]   Liquid Chromatography Electrospray Ionization Mass Spectrometry Analysis of Camphor and Menthol [J].
Hayashi, Keiko ;
Kumagai, Hiroki ;
Sawada, Hirokazu .
CHROMATOGRAPHY, 2023, 44 (01) :33-37
[49]   Determination of diallyldimethylammonium chloride in drinking water by reversed-phase ion-pair chromatography-electrospray ionization mass spectrometry [J].
Jin, F ;
Hu, JY ;
Yang, M ;
Jin, XH ;
He, WJ ;
Han, HD .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1101 (1-2) :222-225
[50]   Determination of sulphonated azo dyes in food by ion-pair liquid chromatography with photodiode array and electrospray mass spectrometry detection [J].
Fuh, MR ;
Chia, KJ .
TALANTA, 2002, 56 (04) :663-671