Simultaneous quantitative analysis of metabolites using ion-pair liquid chromatography - Electrospray ionization mass spectrometry

被引:202
作者
Coulier, Leon [1 ]
Bas, Richard [1 ]
Jespersen, Sonja [1 ]
Verheij, Elwin [1 ]
van der Werf, Mariet J. [1 ]
Hankemeier, Thomas [1 ]
机构
[1] TNO Qual Life, Analyt Res Dept, NL-3700 AJ Zeist, Netherlands
关键词
D O I
10.1021/ac0607616
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We have developed an analytical method, consisting of ion-pair liquid chromatography coupled to electrospray ionization mass spectrometry (IP-LC-ESI-MS), for the simultaneous quantitative analysis of several key classes of polar metabolites, like nucleotides, coenzyme A esters, sugar nucleotides, and sugar bisphosphates. The use of the ion-pair agent hexylamine and optimization of the pH of the mobile phases were critical parameters in obtaining good retention and peak shapes of many of the above-mentioned polar and acidic metabolites that are impossible to analyze using standard reversed-phase LC/MS. Optimum conditions were found when using a gradient from 5 mM hexylamine in water ( pH 6.3) to 90% methanol/ 10% 10 mM ammonium acetate ( pH 8.5). The IP-LC-ESI-MS method was extensively validated by determining the linearity (R-2 > 0.995), sensitivity ( limit of detection 0.1-1 ng), repeatability, and reproducibility ( relative standard deviation < 10%). The IP-LC-ESI-MS method was shown to be a useful tool for microbial metabolomics, i.e., the comprehensive quantitative analysis of metabolites in extracts of microorganisms, and for the determination of the energy charge, i.e., the cellular energy status, as an overall quality measure for the sample workup and analytical protocols.
引用
收藏
页码:6573 / 6582
页数:10
相关论文
共 50 条
[11]   Liquid chromatography - electrospray ionization ion trap mass spectrometry for analysis of mesocarb and its metabolites in human urine [J].
Appolonova, SA ;
Shpak, AV ;
Semenov, VA .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 800 (1-2) :281-289
[12]   Analysis of the metabolites of mesaconitine in rat blood using ultrafast liquid chromatography and electrospray ionization mass spectrometry [J].
Tan, Peng ;
Chen, Xin ;
He, Ruirui ;
Liu, Yonggang .
PHARMACOGNOSY MAGAZINE, 2014, 10 (38) :101-105
[13]   Monitoring of N-nitrosodiethanolamine in cosmetic products by ion-pair complex liquid chromatography and identification with negative ion electrospray ionization mass spectrometry [J].
Ghassemnpour, Alireza ;
Abbaci, Monireh ;
Talebpour, Zahra ;
Spengler, Bernhard ;
Roempp, Andreas .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1185 (01) :43-48
[14]   Simultaneous Analysis of Strychnine and Brucine and their Major Metabolites by Liquid Chromatography-Electrospray Ion Trap Mass Spectrometry [J].
Chen, Xueguo ;
Lai, Yongquan ;
Cai, Zongwei .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2012, 36 (03) :171-176
[15]   Ion-pair reversed-phase liquid chromatography-electrospray mass spectrometry for the analysis of underivatized small peptides [J].
Petritis, K ;
Brussaux, S ;
Guenu, S ;
Elfakir, C ;
Dreux, M .
JOURNAL OF CHROMATOGRAPHY A, 2002, 957 (02) :173-185
[16]   Simultaneous determination of nitroglycerin and dinitrate metabolites in metabolism studies using liquid chromatography-mass spectrometry with electrospray ionization [J].
Miyayama, T ;
Tsou, PS ;
Fung, SM ;
Fung, HL .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 835 (1-2) :21-26
[17]   Mutation scanning by ion-pair reversed-phase high-performance liquid chromatography electrospray ionization mass spectrometry (ICEMS) [J].
Oberacher, H ;
Huber, CG ;
Oefner, PJ .
HUMAN MUTATION, 2003, 21 (01) :86-95
[18]   Quantitative Analysis of Ketoprofen Enantiomers by Liquid Chromatography/Electrospray Ionization-Mass Spectrometry [J].
Yang, Fen ;
Jin, Dongri .
PROCEEDINGS OF THE 2016 INTERNATIONAL CONFERENCE ON BIOLOGICAL ENGINEERING AND PHARMACY (BEP 2016), 2016, 3 :198-201
[19]   Quantitative analysis of diclazuril in animal plasma by liquid chromatography/electrospray ionization mass spectrometry [J].
Croubels, S ;
Cherlet, M ;
De Backer, P .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (15) :1463-1469
[20]   Structural determination and quantitative analysis of bacterial phospholipids using liquid chromatography electrospray ionization mass spectrometry [J].
Fang, JS ;
Barcelona, MJ .
JOURNAL OF MICROBIOLOGICAL METHODS, 1998, 33 (01) :23-35