A hybrid material composed of graphitic carbon nitride and magnetite (Fe3O4) for magnetic solid-phase extraction of trace levels of hydroxylated polycyclic aromatic hydrocarbons

被引:26
作者
Nian, Qixun [1 ]
Wang, Xuesheng [1 ]
Wang, Manman [1 ]
Zuo, Guifu [2 ]
机构
[1] North China Univ Sci & Technol, Sch Publ Hlth, 21 Bohai Rd, Tangshan 063210, Hebei, Peoples R China
[2] North China Univ Sci & Technol, Coll Mat Sci & Engn, 21 Bohai Rd, Tangshan 063210, Hebei, Peoples R China
关键词
Carbon-based materials; Magnetic composites; Adsorbent; Solvothermal method; Sample pretreatment; Urinary metabolites; Biological sample analysis; Urine; High performance liquid chromatography; Fluorescence detection; METABOLITES; NANOPARTICLES; EXPOSURE; FACILE; PAHS; MICROEXTRACTION; QUANTIFICATION; ADSORPTION; RISK;
D O I
10.1007/s00604-019-3607-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Magnetic carbon nitride composites were synthesized via a solvothermal reaction and developed as an effective adsorbent for magnetic solid-phase extraction of trace hydroxylated polycyclic aromatic hydrocarbons (OH-PAHs) from urine samples prior to their determination by HPLC. The sorbent was characterized by Fourier transform infrared spectrometry, X-ray diffractometry, scanning electron microscopy, vibrating sample magnetometry and solvent stability experiments. The adsorption of hydroxy-PAHs is better by a factor or 20 to 49 compared to bare Fe3O4 and comparable that of a commercial C-18 sorbent. The adsorbent amount, adsorption time and eluting solvent and volume were optimized. The complete extraction for the OH-PAHs at a level of 40ngmL(-1) and by using 4mg sorbent is completed within 3min. With an enzymatic hydrolyzed urine sample loading volume of 2mL, enhancement factors in the range of 9-10, and a limit of detection (at S/N=3) of 0.08ng.mL(-1) were achieved. The method showed a linear response in the 0.25-250ng.mL(-1) hydroxy-PAH concentration range, and intra-day and inter-day precisions are 1.5-7.7% and 2.2-8.7%, respectively. The recovery from spiked urine samples ranged from 90.1% to 102%. The sorbent was stable over 10 successive cycles of extraction/desorption of urine sample without significant loss of extraction efficiency. The method was successfully applied for the determination of OH-PAHs in urine samples of smoking volunteers.
引用
收藏
页数:9
相关论文
共 39 条
[1]  
[Anonymous], ANAL BIOANAL CHEM
[2]   PM25-bound oxygenated PAHs, nitro-PAHs and parent-PAHs from the atmosphere of a Chinese megacity: Seasonal variation, sources and cancer risk assessment [J].
Bandowe, Benjamin A. Musa ;
Meusel, Hannah ;
Huang, Ru-jin ;
Ho, Kinfai ;
Cao, Junji ;
Hoffmann, Thorsten ;
Wilcke, Wolfgang .
SCIENCE OF THE TOTAL ENVIRONMENT, 2014, 473 :77-87
[3]   Application of nano-sized multi-template imprinted polymer for simultaneous extraction of polycyclic aromatic hydrocarbon metabolites in urine samples followed by ultra-high performance liquid chromatographic analysis [J].
Chauhan, Abhishek ;
Bhatia, Tejasvi ;
Singh, Amarnath ;
Saxena, Prem Narain ;
Kesavchandran, C. ;
Mudiam, Mohana Krishna Reddy .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 985 :110-118
[4]   Engineering the nanoarchitecture and texture of polymeric carbon nitride semiconductor for enhanced visible light photocatalytic activity [J].
Dong, Fan ;
Wang, Zhenyu ;
Sun, Yanjuan ;
Ho, Wing-Kei ;
Zhang, Haidong .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2013, 401 :70-79
[5]   Magnetic graphitic carbon nitride nanoparticles covalently modified with an ethylenediamine for dispersive solid-phase extraction of lead(II) and cadmium(II) prior to their quantitation by FAAS [J].
Fahimirad, Bahareh ;
Asghari, Alireza ;
Rajabi, Maryam .
MICROCHIMICA ACTA, 2017, 184 (08) :3027-3035
[6]   Co-solvent enhanced adsorption with magnetic velvet-like carbon nitride for high efficiency solid phase extraction [J].
Fan, Shanshan ;
Zhu, Jun ;
Ren, Lixuan ;
Wang, Man ;
Bi, Wentao ;
Li, Huihui ;
Huang, Xiaohua ;
Chen, David Da Yong .
ANALYTICA CHIMICA ACTA, 2017, 960 :63-71
[7]   Determination of Urinary PAH Metabolites Using DLLME Hyphenated to Injector Port Silylation and GC-MS-MS [J].
Gupta, Manoj Kumar ;
Jain, Rajeev ;
Singh, Pratibha ;
Ch, Ratnasekhar ;
Mudiam, Mohana Krishna Reddy .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2015, 39 (05) :365-373
[8]   Graphitic carbon nitrides (g-C3N4) with comparative discussion to carbon materials [J].
Inagaki, Michio ;
Tsumura, Tomoki ;
Kinumoto, Tarou ;
Toyoda, Masahiro .
CARBON, 2019, 141 :580-607
[9]   Application of sunflower stalk-carbon nitride nanosheets as a green sorbent in the solid-phase extraction of polycyclic aromatic hydrocarbons followed by high-performance liquid chromatography [J].
Khosrowshahi, Elnaz Marzi ;
Razmi, Habib .
JOURNAL OF SEPARATION SCIENCE, 2018, 41 (09) :2020-2028
[10]   A review of airborne polycyclic aromatic hydrocarbons (PAHs) and their human health effects [J].
Kim, Ki-Hyun ;
Jahan, Shamin Ara ;
Kabir, Ehsanul ;
Brown, Richard J. C. .
ENVIRONMENT INTERNATIONAL, 2013, 60 :71-80