The effect of gel homogeneity on dose response in a low-density polymer gel dosimeter for radiation therapy

被引:1
作者
Gholami, Mehrdad [1 ]
Shahbazi-Gahrouei, Daryoush [2 ]
机构
[1] Lorestan Univ Med Sci, Dept Med Phys & Radiat Sci, Khorramabad, Iran
[2] Isfahan Univ Med Sci, Sch Med, Dept Med Phys, Esfahan, Iran
关键词
Gel homogeneity; low-density polymer gel dosimetry; radiation therapy; T2-weighted images; MRI; OPTIMIZATION;
D O I
10.4103/0973-1482.183204
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: The human body consists of a variety of tissues and cavities with different physical and radiological properties. The most important among these are tissues and cavities including lungs, oral cavities, teeth, nasal passages, sinuses, and bones. Thus, the dose distribution in these tissues cannot be verified with soft tissue equivalent polymer gel dosimeters. This study is conducted to evaluate the effect of homogeneity on dose response of an anoxic low-density polymer gel dosimeter for radiation therapy. Materials and Methods: The low-density polymer gel dosimeter is composed of 12% gelatin, 5% methacrylic acid, 0.15% sodium dodecyl sulfate, 10 mm tetrakis (hydroxymethyl) phosphonium chloride, and 83% ultrapure deionized water. The time between irradiation and scanning for all gels experiments was 18 h. The gel dosimeters were imaged using a 1.5 T clinical magnetic resonance imaging scanner in a transmitter/receiver head coil. Results: The low-density gels had a mass density between 0.35 g/cm(3) and 0.45 g/cm(3) and the computed tomography (CT) values varied from approximately -650 to -750 Hounsfield units. It is clear that the CT numbers of the fabricated gel are close to those of the normal human lung tissue, which ranges from -770 to -875 Hounsfield units. Conclusion: Findings of the present study showed that if the density and homogeneity of the low-density polymer gel dosimeters are equal to those of the normal lung tissue, it may be used to measure the three dimensional dose distributions in lung tissue during radiation therapy.
引用
收藏
页码:563 / 566
页数:4
相关论文
共 17 条
  • [1] Polymer gel dosimetry
    Baldock, C.
    De Deene, Y.
    Doran, S.
    Ibbott, G.
    Jirasek, A.
    Lepage, M.
    McAuley, K. B.
    Oldham, M.
    Schreiner, L. J.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (05) : R1 - R63
  • [2] QUANTITATIVE ULTRASONIC ELASTOGRAPHY FOR GEL DOSIMETRY
    Crescenti, Remo A.
    Bamber, Jeffrey C.
    Oberai, Assad A.
    Barbone, Paul E.
    Richter, Joseph P.
    Rivas, Carlos
    Bush, Nigel L.
    Webb, Steve
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2010, 36 (02) : 268 - 275
  • [3] De Deene Y, 2012, J PHYS C SERIES, V444, P204
  • [4] Three dimensional radiation dosimetry in lung-equivalent regions by use of a radiation sensitive gel foam: Proof of principle
    De Deene, Yves
    Vergote, Koen
    Claeys, Carolien
    De Wagter, Carlos
    [J]. MEDICAL PHYSICS, 2006, 33 (07) : 2586 - 2597
  • [5] Polymer gels for magnetic resonance imaging of radiation dose distributions at normal room atmosphere
    Fong, PM
    Keil, DC
    Does, MD
    Gore, JC
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (12) : 3105 - 3113
  • [6] Dose response evaluation of a low density anoxic polymer gel dosimeter using MRI
    Gholami, M.
    Shahbazi-Gahrouei, D.
    Pourfallah, T. Allahverdi
    [J]. INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2015, 13 (03): : 243 - 249
  • [7] Development and optimization of a 2-hydroxyethylacrylate MRI polymer gel dosimeter
    Gustavsson, H
    Bäck, SÅJ
    Lepage, M
    Rintoul, L
    Baldock, C
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (02) : 227 - 241
  • [8] Dose response evaluation of a low-density normoxic polymer gel dosimeter using MRI
    Haraldsson, P
    Karlsson, A
    Wieslander, E
    Gustavsson, H
    Bäck, SÅJ
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (04) : 919 - 928
  • [9] Dose resolution optimization of polymer gel dosimeters using different monomers
    Lepage, M
    Jayasakera, PM
    Bäck, SÅJ
    Baldock, C
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (10) : 2665 - 2680
  • [10] NMR RELAXATION ENHANCEMENT IN GELS POLYMERIZED AND CROSS-LINKED BY IONIZING-RADIATION - A NEW APPROACH TO 3D DOSIMETRY BY MRI
    MARYANSKI, MJ
    GORE, JC
    KENNAN, RP
    SCHULZ, RJ
    [J]. MAGNETIC RESONANCE IMAGING, 1993, 11 (02) : 253 - 258