Effects of acupuncture at the Hoku acupoint on the pulsatile laser Doppler signal at the heartbeat frequency

被引:20
作者
Hsiu, Hsin [2 ]
Hsu, Wei-Chen [1 ]
Hsu, Chia-Liang [2 ]
Jan, Ming-Yie [3 ]
Wang-Lin, Yuh-Ying [3 ,4 ]
机构
[1] Taipei City Hosp, RenAi Branch, Taipei, Taiwan
[2] Yuan Ze Univ, Dept Elect Engn, Tao Yuan, Taiwan
[3] Acad Sinica, Inst Phys, Biophys Lab, Taipei, Taiwan
[4] Natl Taiwan Normal Univ, Dept Phys, Taipei 117, Taiwan
关键词
Acupuncture; Pulse; Laser Doppler; Microcirculation; SKIN BLOOD-FLOW; SYMPATHETIC-NERVE; PERFUSION SIGNAL; STIMULATION; MICROCIRCULATION; OSCILLATIONS; HYPERTENSION; HUMANS; RATS;
D O I
10.1007/s10103-008-0610-y
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We aimed to assess the effects of acupuncture by analyzing the alternating current (AC) component of skin blood-flow signals (around the heartbeat frequency) simultaneously recorded at the Hoku acupoint, which is an important acupoint in oriental medicine, and two nearby non-acupoints following acupuncture stimulation (AS). Laser Doppler flowmetry signals were measured in 28 experiments on nine volunteers. Each experiment involved the recording of a 20-min control-data sequence and two sets of effects data recorded 0-20 min and 50-70 min after the AS had been stopped. The direct current (DC) and AC components (DCflux and ACflux, respectively), pulse width (PW), and foot delay time (FDT) of the flux signal were calculated. The DCflux, ACflux, PW, and FDT were all significantly increased only at Hoku following AS. Regression analysis between the DCflux and ACflux revealed that the slope was largest (> 1) at Hoku among the measurement sites. Our results indicated that both the DCflux and ACflux in the microcirculatory perfusion were increased by stimulation at the Hoku acupoint, with the change being greatest for the latter. Parameters calculated from the pulsatile flux waveform, such as the PW and FDT, could contribute to noninvasive evaluations of the sympathetic neural activities and of the improvement in perfusion following AS.
引用
收藏
页码:553 / 560
页数:8
相关论文
共 25 条
[1]   RELATIONSHIP BETWEEN PHASIC CHANGES IN HUMAN-SKIN BLOOD-FLOW AND AUTONOMIC TONE [J].
BERNARDI, L ;
ROSSI, M ;
FRATINO, P ;
FINARDI, G ;
MEVIO, E ;
ORLANDI, C .
MICROVASCULAR RESEARCH, 1989, 37 (01) :16-27
[2]   INHIBITION OF SYMPATHETIC NERVOUS-SYSTEM BY ACUPUNCTURE [J].
CAO, XD ;
XU, SF ;
LU, WX .
ACUPUNCTURE & ELECTRO-THERAPEUTICS RESEARCH, 1983, 8 (01) :25-35
[3]   Evaluating microcirculation by pulsatile laser Doppler signal [J].
Chao, PT ;
Jan, MY ;
Hsiu, H ;
Hsu, TL ;
Wang, WK ;
Wang, YYL .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (04) :845-854
[4]   SYMPATHETIC EFFECTS OF MANUAL AND ELECTRICAL ACUPUNCTURE OF THE TSUSANLI KNEE POINT - COMPARISON WITH THE HOKU HAND POINT SYMPATHETIC EFFECTS [J].
ERNST, M ;
LEE, MHM .
EXPERIMENTAL NEUROLOGY, 1986, 94 (01) :1-10
[5]   Non-invasive assessment of microvascular endothelial function by laser doppler flowmetry in patients with essential hypertension [J].
Farkas, K ;
Kolossváry, E ;
Járai, Z ;
Nemcsik, J ;
Farsang, C .
ATHEROSCLEROSIS, 2004, 173 (01) :97-102
[6]   Effect of sensory stimulation (acupuncture) on sympathetic and parasympathetic activities in healthy subjects [J].
Haker, E ;
Egekvist, H ;
Bjerring, P .
JOURNAL OF THE AUTONOMIC NERVOUS SYSTEM, 2000, 79 (01) :52-59
[7]   Time course of changes in nail fold microcirculation induced by acupuncture stimulation at the Waiguan acupoints [J].
Hsieh, Ching-Liang ;
Chang, Yung-Ming ;
Tang, Nou-Ying ;
Lin, I-hsin ;
Liu, Chung-Hsiang ;
Lin, Jaung-Geng .
AMERICAN JOURNAL OF CHINESE MEDICINE, 2006, 34 (05) :777-785
[8]   Connection between RR-interval length and the pulsatile microcirculatory flow [J].
Hsiu, Hsin ;
Hsu, Chia-Liang ;
Chiang, Wen-Rei ;
Chao, Pin-Tsun ;
Hsu, Tse-Lin ;
Jan, Ming-Yie ;
Wang, Wei-Kung ;
Wang, Yuh-Ying Lin .
PHYSIOLOGICAL MEASUREMENT, 2008, 29 (02) :245-254
[9]   Microcirculatory characteristics of acupuncture points obtained by laser Doppler flowmetry [J].
Hsiu, Hsin ;
Huang, Shih-Min ;
Chao, Pin-Tsun ;
Jan, Ming-Yie ;
Hsu, Tse-Lin ;
Wang, Wei-Kung ;
Wang, Yuh-Ying Lin .
PHYSIOLOGICAL MEASUREMENT, 2007, 28 (10) :N77-N86
[10]   EFFECT OF PULSE NUMBER ON THE PULSE- BASED SYNCHRONIZED-AVERAGING ANALYSIS IN LASER DOPPLER SIGNAL [J].
Hsiu, Hsin ;
Chao, Pin-Tsun ;
Chiang, Wen-Rei ;
Hsu, Chia-Liang ;
Jan, Ming-Yie ;
Wang, Wei-Kung ;
Wang, Yuh-Ying Lin .
BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2007, 19 (03) :179-185