An Integrated System for the Segmentation of Atherosclerotic Carotid Plaque Ultrasound Video

被引:42
作者
Loizou, Christos P. [1 ]
Petroudi, Styliani [2 ]
Pantziaris, Marios [3 ]
Nicolaides, Andrew N. [4 ]
Pattichis, Constantinos S. [2 ]
机构
[1] Intercoll, Dept Comp Sci, Limassol, Cyprus
[2] Univ Cyprus, Dept Comp Sci, Nicosia, Cyprus
[3] Cyprus Inst Neurol & Genet, Nicosia, Cyprus
[4] Cyprus Cardiovasc Dis Educ Res Trust CDERT, Nicosia, Cyprus
关键词
ACTIVE CONTOURS; ARTERY; IMAGES; MOTION; STROKE; STRAIN; QUANTIFICATION; ALGORITHM; STENOSIS; RISK;
D O I
10.1109/TUFFC.2014.6689778
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The robust border identification of atherosclerotic carotid plaque, the corresponding degree of stenosis of the common carotid artery (CCA), and also the characteristics of the arterial wall, including plaque size, composition, and elasticity, have significant clinical relevance for the assessment of future cardiovascular events. To facilitate the follow-up and analysis of the carotid stenosis in serial clinical investigations, we propose and evaluate an integrated system for the segmentation of atherosclerotic carotid plaque in ultrasound videos of the CCA based on video frame normalization, speckle reduction filtering, M-mode state-based identification, parametric active contours, and snake segmentation. Initially, the cardiac cycle in each video is identified and the video M-mode is generated, thus identifying systolic and diastolic states. The video is then segmented for a time period of at least one full cardiac cycle. The algorithm is initialized in the first video frame of the cardiac cycle, with human assistance if needed, and the moving atherosclerotic plaque borders are tracked and segmented in the subsequent frames. Two different initialization methods are investigated in which initial contours are estimated every 20 video frames. In the first initialization method, the initial snake contour is estimated using morphology operators; in the second initialization method, the Chan-Vese active contour model is used. The performance of the algorithm is evaluated on 43 real CCA digitized videos from B-mode longitudinal ultrasound segments and is compared with the manual segmentations of an expert, available every 20 frames in a time span of 3 to 5 s, covering, in general, 2 cardiac cycles. The segmentation results were very satisfactory, according to the expert objective evaluation, for the two different methods investigated, with true-negative fractions (TNF-specificity) of 83.7 +/- 7.6% and 84.3 +/- 7.5%; true-positive fractions (TPF-sensitivity) of 85.42 +/- 8.1% and 86.1 +/- 8.0%; and between the ground truth and the proposed segmentation method, kappa indices (KI) of 84.6% and 85.3% and overlap indices of 74.7% and 75.4%. The segmentation contours were also used to compute the cardiac state identification and radial, longitudinal, and shear strain indices for the CCA wall and plaque between the asymptomatic and symptomatic groups were investigated. The results of this study show that the integrated system investigated in this study can be successfully used for the automated video segmentation of the CCA plaque in ultrasound videos.
引用
收藏
页码:86 / 101
页数:16
相关论文
共 49 条
[1]  
Abdel-Dayem A. R., 2004, Canadian Conference on Electrical and Computer Engineering 2004 (IEEE Cat. No.04CH37513), P1873, DOI 10.1109/CCECE.2004.1347574
[2]   Real-time extraction of carotid artery contours from ultrasound images [J].
Abolmaesumi, P ;
Sirouspour, MR ;
Salcudean, SE .
13TH IEEE SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS (CBMS 2000), PROCEEDINGS, 2000, :181-186
[3]   Segmentation of real-time three-dimensional ultrasound for quantification of ventricular function: A clinical study on right and left ventricles [J].
Angelini, ED ;
Homma, S ;
Pearson, G ;
Holmes, JW ;
Laine, AF .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (09) :1143-1158
[4]  
[Anonymous], 2000, Industrial Networks and Proximity
[5]   Fully automatic luminal contour segmentation in intracoronary ultrasound imaging - A statistical approach [J].
Brusseau, E ;
de Korte, CL ;
Mastik, F ;
Schaar, J ;
van der Steen, AFW .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (05) :554-566
[6]   Active contours without edges [J].
Chan, TF ;
Vese, LA .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 2001, 10 (02) :266-277
[7]   Quantification of carotid vessel wall and plaque thickness change using 3D ultrasound images [J].
Chiu, Bernard ;
Egger, Micaela ;
Spence, J. David ;
Parraga, Grace ;
Fenster, Aaron .
MEDICAL PHYSICS, 2008, 35 (08) :3691-3710
[8]   Development of 3D ultrasound techniques for carotid artery disease assessment and monitoring [J].
Chiu, Bernard ;
Egger, Micaela ;
Spence, J. David ;
Parraga, Grace ;
Fenster, Aaron .
INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2008, 3 (1-2) :1-10
[9]   Texture-based classification of atherosclerotic carotid plaques [J].
Christodoulou, CI ;
Pattichis, CS ;
Pantziaris, M ;
Nicolaides, A .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (07) :902-912
[10]   Longitudinal movements and resulting shear strain of the arterial wall [J].
Cinthio, Magnus ;
Ahlgren, sa Rydén ;
Bergkvist, Jonas ;
Jansson, Tomas ;
Persson, Hans W. ;
Lindström, Kjell .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2006, 291 (01) :H394-H402