Detached multipinhole small animal SPECT device with real-time calibration

被引:13
作者
DiFilippo, Frank P.
Riffe, Matthew J.
Harsch, Kelley M.
McCabe, N. Patrick
Heston, Warren D.
机构
[1] Cleveland Clin Fdn, Dept Mol & Funct Imaging, Cleveland, OH 44195 USA
[2] Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
[3] Cleveland Clin Fdn, Lerner Res Inst, Cleveland, OH 44195 USA
基金
美国国家卫生研究院;
关键词
calibration; pinhole; single photon emission computed tomography (SPECT); small animal;
D O I
10.1109/TNS.2006.882748
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
High-resolution small animal single photon emission computed tomography (SPECT) with pinhole collimation has become well-established in preclinical research. Conventional scanner designs use custom-fixtures that precisely attach and align pinholes to dedicated detectors. As a lower-cost alternative, we have developed a compact small animal SPECT device with integrated pinholes that is physically detached from gamma camera detectors and uses real-time calibration. The device consists of a shielded lead box with multiple integrated tungsten pinholes on the sides and with a rotating platform at the bottom. The animal or phantom to be imaged is positioned within a hollow cylinder mounted to the platform, with point source markers attached to the cylinder's outer surface. The entire device is placed on the patient table of a standard dual-head gamma camera system with collimators removed. Projection data are acquired with multiple energy windows to separate the point source data from the emission data. The complete geometric calibration is derived through analysis of the point source data. The system matrix is computed based on the calibration parameters and then applied to reconstruction of the emission data. Real-time calibration was found to be robust and accurate, even in the presence of downscatter from Tc-99m emission data or dual-isotope Tc-99m/In-111 emission data. Successful calibration was consistently achieved in all pinhole configurations tried (up to seven pinholes per detector). Accuracy of real-time calibration was demonstrated in phantom studies and animal studies, where structures as small as 0.8 mm could be resolved in reconstructed images. Images appeared to be free of artifacts, and no cross-contamination from the calibration point sources was observed. Real-time calibration is feasible for pinhole SPECT, thus enabling standalone pinhole devices to be used without special alignment fixtures. The calibration accuracy is sufficient for high-resolution small animal studies. The hardware is compatible with nearly all gamma camera models and represents a lower-cost entry-level solution to the field of small animal SPECT.
引用
收藏
页码:2605 / 2612
页数:8
相关论文
共 50 条
  • [41] Fully Digital Beamforming Receiver With a Real-Time Calibration for 5G Mobile Communication
    Kim, Dong-Chan
    Park, Seong-Jin
    Kim, Tae-Wan
    Minz, Laxmikant
    Park, Seong-Ook
    IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 2019, 67 (06) : 3809 - 3819
  • [42] METRIC AND NON-METRIC CAMERAS CALIBRATION FOR THE IMPROVEMENT OF REAL-TIME MONITORING PROCESS RESULTS
    Oniga, Ersilia
    Diac, Maximilian
    ENVIRONMENTAL ENGINEERING AND MANAGEMENT JOURNAL, 2013, 12 (04): : 719 - 726
  • [43] A High-Quality VR Calibration and Real-Time Stitching Framework Using Preprocessed Features
    Saeed, Saleh
    Kakli, Muhammad Umer
    Cho, Yongju
    Seo, Jeongil
    Park, Unsang
    IEEE ACCESS, 2020, 8 : 190300 - 190311
  • [44] Real-Time Wind Field Estimation and Pitot Tube Calibration Using an Extended Kalman Filter
    Zhang, Qian
    Xu, Yifan
    Wang, Xueyun
    Yu, Zelong
    Deng, Tianyi
    MATHEMATICS, 2021, 9 (06)
  • [45] A REAL-TIME EIRP LEVEL 1 CALIBRATION ALGORITHM FOR THE CYGNSS MISSION USING THE ZENITH MEASUREMENTS
    Wang, Tianlin
    Ruf, Christopher
    Gleason, Scott
    Block, Bruce
    McKague, Darren
    O'Brien, Andrew
    2019 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM (IGARSS 2019), 2019, : 8725 - 8728
  • [46] Temperature and Humidity Calibration of a Low-Cost Wireless Dust Sensor for Real-Time Monitoring
    Hojaiji, Hannaneh
    Kalantarian, Haik
    Bui, Alex A. T.
    King, Christine E.
    Sarrafzadeh, Majid
    2017 IEEE SENSORS APPLICATIONS SYMPOSIUM (SAS), 2017,
  • [47] NextGen Calibration Utility for Tool Setup and Matching in Real-Time Automated Visual Inspection Systems
    Edwards, Chris
    Morgan, Cody L.
    Rudolph, John
    Slinker, Danniel
    Panda, Debashis
    2020 31ST ANNUAL SEMI ADVANCED SEMICONDUCTOR MANUFACTURING CONFERENCE (ASMC), 2020,
  • [48] Real-time calibration of the A4 electromagnetic lead fluoride (PbF2) calorimeter
    Baunack, S.
    Rios, D. Balaguer
    Capozza, L.
    Diefenbach, J.
    Frascaria, R.
    Glaeser, B.
    Harrach, D. V.
    Imai, Y.
    Kothe, R.
    Kunne, R.
    Lee, J. H.
    Maas, F. E.
    Espi, M. C. Mora
    Morlet, M.
    Ong, S.
    Schilling, E.
    van de Wiele, J.
    Weinrich, C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 640 (01) : 58 - 68
  • [49] Machine Learning-Driven Calibration of Traffic Models Based on a Real-Time Video Analysis
    Lopukhova, Ekaterina
    Abdulnagimov, Ansaf
    Voronkov, Grigory
    Grakhova, Elizaveta
    APPLIED SCIENCES-BASEL, 2024, 14 (11):
  • [50] Remote on-line calibration of a particulate-iodine monitor of a real-time radiological network
    Baeza, A
    del Rio, LM
    Vasco, J
    RADIOCHIMICA ACTA, 1997, 79 (01) : 17 - 23