A hybrid biomechanical intensity based deformable image registration of lung 4DCT

被引:1
|
作者
Samavati, Navid [1 ]
Velec, Michael [2 ]
Brock, Kristy [3 ]
机构
[1] Univ Toronto, Inst Biomat & Biomed Engn, Toronto, ON M5S 1A1, Canada
[2] Univ Toronto, Inst Med Sci, Toronto, ON, Canada
[3] Univ Michigan, Dept Radiat Oncol, Ann Arbor, MI USA
来源
关键词
Deformable Image Registration; 4DCT; Lung Registration; Breathing Motion; Biomechanical Modeling; Hybrid Registration; Intensity Based Registration; MOTION;
D O I
10.1117/12.2043560
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Deformable Image Registration (DIR) has been extensively studied over the past two decades due to its essential role in many image-guided interventions. Morfeus is a DIR algorithm that works based on finite element biomechanical modeling. However, Morfeus does not utilize the entire image contrast and features which could potentially lead to a more accurate registration result. A hybrid biomechanical intensity-based method is proposed to investigate this potential benefit Inhale and exhale 4DCT lung images of 26 patients were initially registered using Morfeus by modeling contact surface between the lungs and the chest cavity. The resulting deformations using Morfeus were refined using a B-spline intensity-based algorithm (Drop, Munich, Germany). Important parameters in Drop including grid spacing, number of pyramids, and regularization coefficient were optimized on 10 randomly-chosen patients (out of 26). The remaining parameters were selected empirically. Target Registration Error (TRE) was calculated by measuring the Euclidean distance of common anatomical points on both images before and after registration. For each patient a minimum of 30 points/lung were used. The Hybrid method resulted in mean +/- SD (90th%) TRE of 1.5 +/- 1.4 (2.8) mm compared to 3.1 +/- 2.0 (5.6) using Morfeus and 2.6 +/- 2.6 (6.2) using Drop alone.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] ORRN: An ODE-Based Recursive Registration Network for Deformable Respiratory Motion Estimation With Lung 4DCT Images
    Liang, Xiao
    Lin, Shan
    Liu, Fei
    Schreiber, Dimitri
    Yip, Michael
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2023, 70 (12) : 3265 - 3276
  • [32] TIME-VARYING LUNG VENTILATION ANALYSIS OF 4DCT USING IMAGE REGISTRATION
    Ding, Kai
    Du, Kaifang
    Cao, Kunlin
    Christensen, Gary E.
    Reinhardt, Joseph M.
    2011 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING, 2011, : 5772 - 5775
  • [33] Time-varying lung ventilation analysis of 4DCT using image registration
    Ding, Kai
    Du, Kaifang
    Cao, Kunlin
    Christensen, Gary E.
    Reinhardt, Joseph M.
    ICASSP, IEEE International Conference on Acoustics, Speech and Signal Processing - Proceedings, 2011, : 5772 - 5775
  • [34] Biomechanical model-based 4DCT simulation
    Li, Feng
    Porikli, Fatih
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING-IMAGING AND VISUALIZATION, 2015, 3 (04): : 222 - 233
  • [35] Deformable Registration Using Multi-Resolution Demons Algorithm for 4DCT
    Li, Dengwang
    Yin, Yong
    MEDICAL PHYSICS, 2012, 39 (06) : 3672 - 3673
  • [36] Characterizing Accuracy in 4DCT Deformable Registration Using the POPI M odel
    Piper, J.
    Duchateau, M.
    Nelson, A.
    Verellen, D.
    De Ridder, M. Mark
    MEDICAL PHYSICS, 2013, 40 (06)
  • [37] Development of a Hyrbid Biomechanical Model Based Deformable Image Registration; Application in Lung
    Samavati, N.
    Al-Mayah, A.
    Brock, K.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [38] Biomechanical Deformable Image Registration of Longitudinal Lung CT Images
    Cazoulat, G.
    Owen, D.
    Matuszak, M.
    Balter, J.
    Brock, K.
    MEDICAL PHYSICS, 2015, 42 (06) : 3285 - 3285
  • [39] Dosimetric study of three-dimensional static and dynamic SBRT radiotherapy for hepatocellular carcinoma based on 4DCT image deformable registration
    Ma, Changdong
    Duan, Jinghao
    Yu, Shuang
    Ma, Changsheng
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (02): : 60 - 66
  • [40] Kidney motion in children and young people quantified using 4DCT deformable registration
    Lavan, N.
    Mc Quaid, D.
    Smyth, G.
    Vaidya, S.
    Saran, F.
    Oelfke, U.
    Mandeville, H.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S1109 - S1110