Temperature influence on DXA measurements: bone mineral density acquisition in frozen and thawed human femora

被引:21
作者
Waehnert, Dirk [1 ]
Hoffmeier, Konrad L. [1 ]
Lehmann, Gabriele [3 ]
Froeber, Rosemarie [4 ]
Hofmann, Gunther O. [1 ,2 ]
Mueckley, Thomas [1 ]
机构
[1] Univ Jena, Ctr Trauma & Hand & Reconstruct Surg, D-07747 Jena, Germany
[2] Berufsgenossenschaftliche Kliniken Bergmannstrost, D-06112 Halle, Germany
[3] Univ Jena, Ctr Internal Med 3, Dept Rheumatl Osteol, D-07747 Jena, Germany
[4] Univ Jena, Dept Anat 1, D-07743 Jena, Germany
关键词
X-RAY ABSORPTIOMETRY; INVASIVE STABILIZATION SYSTEM; DISTAL FEMUR FRACTURES; ANGLED BLADE PLATE; BIOMECHANICAL EVALUATION; INTERNAL-FIXATION; INTRAMEDULLARY NAILS; INTERLOCKING; ROTATION; CADAVER;
D O I
10.1186/1471-2474-10-25
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Determining bone mineral density (BMD) with dual-energy x-ray absorptiometry (DXA) is an established and widely used method that is also applied prior to biomechanical testing. However, DXA is affected by a number of factors. In order to delay decompositional processes, human specimens for biomechanical studies are usually stored at about -20 degrees C; similarly, bone mineral density measurements are usually performed in the frozen state. The aim of our study was to investigate the influence of bone temperature on the measured bone mineral density. Methods: Using DXA, bone mineral density measurements were taken in 19 fresh-frozen human femora, in the frozen and the thawed state. Water was used to mimic the missing soft tissue around the specimens. Measurements were taken with the specimens in standardized internal rotation. Total-BMD and single-BMD values of different regions of interest were used for evaluation. Results: Fourteen of the 19 specimens showed a decrease in BMD after thawing. The measured total-BMD of the frozen specimens was significantly (1.4%) higher than the measured BMD of the thawed specimens. Conclusion: Based on our findings we recommend that the measurement of bone density, for example prior to biomechanical testing, should be standardized to thawed or frozen specimens. Temperature should not be changed during measurements. When using score systems for data interpretation (e. g. T-or Z-score), BMD measurements should be performed only on thawed specimens.
引用
收藏
页数:7
相关论文
共 19 条
[1]   Effects of anteversion on femoral bone mineral density and geometry measured by dual energy X-ray absorptiometry: A cadaver study [J].
Cheng, XG ;
Nicholson, PHF ;
Boonen, S ;
Brys, P ;
Lowet, G ;
Nijs, J ;
Dequeker, J .
BONE, 1997, 21 (01) :113-117
[2]   The effect of room temperature on dual-energy X-ray absorptiometry [J].
Culton, NL ;
Pocock, NA .
OSTEOPOROSIS INTERNATIONAL, 2003, 14 (02) :137-140
[3]  
Girard M S, 1994, Orthop Rev, V23, P38
[4]   EFFECT OF FEMORAL ROTATION ON BONE-MINERAL DENSITY-MEASUREMENTS WITH DUAL-ENERGY X-RAY ABSORPTIOMETRY [J].
GOH, JCH ;
LOW, SL ;
BOSE, K .
CALCIFIED TISSUE INTERNATIONAL, 1995, 57 (05) :340-343
[5]   Biomechanical analysis of supracondylar femoral fractures fixed with modern retrograde intramedullary nails [J].
Hora, N ;
Markel, DC ;
Haynes, A ;
Grimm, MJ .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1999, 13 (08) :539-544
[6]   Improved intramedullary nail interlocking in osteoporotic bone [J].
Ito, K ;
Hungerbühler, R ;
Wahl, D ;
Grass, F .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2001, 15 (03) :192-196
[7]   Distal femoral fixation: A laboratory comparison of the 95 degrees plate, antegrade and retrograde inserted reamed intramedullary nails [J].
Koval, KJ ;
Kummer, FJ ;
Bharam, S ;
Chen, DY ;
Halder, S .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1996, 10 (06) :378-382
[8]   Effect of leg rotation on hip bone mineral density measurements [J].
Lekamwasam, S ;
Lenora, RSJ .
JOURNAL OF CLINICAL DENSITOMETRY, 2003, 6 (04) :331-336
[9]   Effect of fixation, soft-tissues, and scan projection on bone mineral measurements with dual energy X-ray absorptiometry (DXA) [J].
Lochmüller, EM ;
Krefting, N ;
Bürklein, D ;
Eckstein, F .
CALCIFIED TISSUE INTERNATIONAL, 2001, 68 (03) :140-145
[10]   Biomechanical evaluation of the less invasive stabilization system for the internal fixation of distal femur fractures [J].
Marti, A ;
Fankhauser, C ;
Frenk, A ;
Cordey, J ;
Gasser, B .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2001, 15 (07) :482-487