The effect of water temperature lift on the performance of cascade heat pump system

被引:36
作者
Kim, Dong Ho [1 ]
Kim, Min Soo [1 ]
机构
[1] Seoul Natl Univ, Dept Mech & Aerosp Engn, Div WCU Multiscale Mech Design, Seoul 151744, South Korea
基金
新加坡国家研究基金会;
关键词
Cascade; Temperature lift; Secondary fluid; Mass flow rate; Intermediate temperature; OPTIMIZATION; DESIGN; STAGE;
D O I
10.1016/j.applthermaleng.2014.03.036
中图分类号
O414.1 [热力学];
学科分类号
摘要
The mass flow rate of secondary fluid in a water heater heat pump determines not only the discharge water temperature but also the heat pump performances. As water flow rate decreases, water discharge temperature increases; however, the COP (coefficient of performance) deteriorates due to the increase of high side pressure. In this study, cascade cycle which is used for a water heater heat pump was studied to verify the effect of the water temperature lift in terms of pressure and performance change. Also, the optimal intermediate temperature of cascade cycle with respect to temperature lift was studied and this temperature was adopted for a heat pump transient operation. The heat pump was operated to meet the constant heating capacity and target intermediate temperature by PID control of compressor speed. The transient results showed that water temperature lift determines not only the vertical temperature profile of water reservoir but also the transient performance. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:273 / 282
页数:10
相关论文
共 22 条
[1]   Two-stage air-source heat pump for residential heating and cooling applications in northern US climates [J].
Bertsch, Stefan S. ;
Groll, Eckhard A. .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2008, 31 (07) :1282-1292
[2]   CO2-C3H8 cascade refrigeration-heat pump system: Heat exchanger inventory optimization and its numerical verification [J].
Bhattacharyya, Souvik ;
Mukhopadhyay, S. ;
Sarkar, J. .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2008, 31 (07) :1207-1213
[3]   Study on the LWT control schemes of a heat pump for hot water supply [J].
Choi, Jong Min .
RENEWABLE ENERGY, 2013, 54 :20-25
[4]   Advances in heat pump systems: A review [J].
Chua, K. J. ;
Chou, S. K. ;
Yang, W. M. .
APPLIED ENERGY, 2010, 87 (12) :3611-3624
[5]   Comparison of CO2 heat pump water heater performance with baseline cycle and two high COP cycles [J].
Fernandez, Nicholas ;
Hwang, Yunho ;
Radermacher, Reinhard .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2010, 33 (03) :635-644
[6]   A fast response heat pump water heater using thermostat made from shape memory alloy [J].
Huang, B. J. ;
Wang, J. H. ;
Wu, J. H. ;
Yang, P. E. .
APPLIED THERMAL ENGINEERING, 2009, 29 (01) :56-63
[7]   Domestic air-conditioner and integrated water heater for subtropical climate [J].
Ji, J ;
Chow, TT ;
Pei, G ;
Dong, J ;
He, W .
APPLIED THERMAL ENGINEERING, 2003, 23 (05) :581-592
[8]   Performance comparison between a single-stage and a cascade multi-functional heat pump for both air heating and hot water supply [J].
Jung, Hae Won ;
Kang, Hoon ;
Yoon, Won Jae ;
Kim, Yongchan .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2013, 36 (05) :1431-1441
[9]   Optimal temperature between high and low stage cycles for R134a/R410A cascade heat pump based water heater system [J].
Kim, Dong Ho ;
Park, Han Saem ;
Kim, Min Soo .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2013, 47 :172-179
[10]   Design of a steady-state detector for fault detection and diagnosis of a residential air conditioner [J].
Kim, Minsung ;
Yoon, Seok Ho ;
Domanski, Piotr A. ;
Payne, W. Vance .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2008, 31 (05) :790-799