A practical EPR dosimetry system for routine use in radiotherapy: uncertainty analysis of lithium formate dosimeters at the therapeutic dose level

被引:8
作者
Hoefel, Sebastian [1 ,2 ,3 ]
Stehle, Michael [1 ,2 ]
Zwicker, Felix [3 ]
Fix, Michael K. [4 ,5 ,6 ]
Drescher, Malte [1 ,2 ]
机构
[1] Univ Konstanz, Dept Chem, Constance, Germany
[2] Univ Konstanz, Konstanz Res Sch Chem Biol, Constance, Germany
[3] Klinikum Konstanz, Klin & Praxis Strahlentherapie, Constance, Germany
[4] Bern Univ Hosp, Inselspital, Div Med Radiat Phys, Bern, Switzerland
[5] Bern Univ Hosp, Inselspital, Dept Radiat Oncol, Bern, Switzerland
[6] Univ Bern, Bern, Switzerland
关键词
EPR dosimetry; alanine; lithium formate; radiotherapy; uncertainty;
D O I
10.1088/1361-6560/ab9414
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In electron paramagnetic resonance (EPR) dosimetry, solid dosimeter materials such as alanine (AL) or, more recently, lithium formate monohydrate (LFM) are typically used. These materials offer high potential for applications in radiotherapy based on their favorable dosimetric properties. Nevertheless, EPR dosimetry is not widespread in the clinics. This work presents an uncertainty analysis of EPR dosimetry in the dose range from 1 to 70 Gy using a compact spectrometer and applying a practical procedure being suitable for routine use in radiotherapy. The performances of self-pressed LFM pellets and commercial AL pellets are compared side by side. All pellets had a diameter of 4 mm and a height of 2 mm (AL) or 4 mm (LFM). The mean pellet mass was 35.81 mg and 73.81 mg for AL and LFM, respectively. Before irradiation, the pellets were stored for at least 8 weeks at 34 +/- 2% relative humidity. For irradiation, the pellets were put inside an airtight capsule. In total, 25 pellets per material were examined. The pellets were irradiated at a temperature of 25 +/- 2.5 (2 sigma) degrees C to doses of either 1, 5, 20, 50 or 70 Gy (five pellets per dose value and material) by a clinical 6 MV photon beam. Measurement uncertainties were obtained from five independent readouts per pellet within five weeks following irradiation using a benchtop EPR spectrometer. The measurement time of a single readout was restricted to 10 min per pellet. Dose values were derived from EPR signal amplitudes using a specifically developed spectral fitting procedure. Signal fading characteristics were analyzed and taken into account during evaluation. The relative dose uncertainties (1 sigma) for a single readout at doses >= 5 Gy are below 2.8% (AL) and 1.1% (LFM) but increase to 12.3% (AL) and 2.6% (LFM) at 1 Gy. By averaging five independent readouts, the uncertainties at 1 Gy decrease to 2.6% (AL) and 0.8% (LFM). In terms of dose uncertainty, the LFM pellets are superior to the commercial AL pellets owing to their narrower EPR spectrum and approximately doubled mass resulting in higher EPR signal intensities. In case of the LFM pellets, the EPR dosimetry system shows a high level of precision (< 3%) down to 1 Gy being preferable for applications in radiotherapy. The uncertainties can be further decreased by averaging multiple dose values from independent readouts.
引用
收藏
页数:15
相关论文
共 50 条
[1]   END-TO-END AUDIT: COMPARISON OF TLD AND LITHIUM FORMATE EPR DOSIMETRY [J].
Adolfsson, Emelie ;
Wesolowska, Paulina ;
Izewska, Joanna ;
Lund, Eva ;
Tedgren, Asa Carlsson .
RADIATION PROTECTION DOSIMETRY, 2019, 186 (01) :119-122
[2]   A system for remote dosimetry audit of 3D-CRT, IMRT and VMAT based on lithium formate dosimetry [J].
Adolfsson, Emelie ;
Gustafsson, Hakan ;
Lund, Eva ;
Carlsson, Gudrun Alm ;
Olsson, Sara ;
Tedgren, Asa Carlsson .
RADIOTHERAPY AND ONCOLOGY, 2014, 113 (02) :279-282
[3]   Optimisation of an EPR dosimetry system for robust and high precision dosimetry [J].
Adolfsson, Emelie ;
Tedgren, Asa Carlsson ;
Carlsson, Gudrun Alm ;
Gustafsson, Hakan ;
Lund, Eva .
RADIATION MEASUREMENTS, 2014, 70 :21-28
[4]   Investigation of signal fading in lithium formate EPR dosimeters using a new sensitive method [J].
Adolfsson, Emelie ;
Karlsson, Mattias ;
Carlsson, Gudrun Alm ;
Tedgren, Asa Carlsson ;
Lund, Eva ;
Olsson, Sara ;
Gustafsson, Hakan .
PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (08) :2209-2217
[5]   Development of a secondary standard for the absorbed dose to water based on the alanine EPR dosimetry system [J].
Anton, M .
APPLIED RADIATION AND ISOTOPES, 2005, 62 (05) :779-795
[6]   Postirradiation effects in alanine dosimeter probes of two different suppliers [J].
Anton, Mathias .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (05) :1241-1258
[7]   Uncertainties in alanine/ESR dosimetry at the Physikalisch-Technische Bundesanstalt [J].
Anton, Mathias .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (21) :5419-5440
[8]   FADING CHARACTERISTICS OF IRRADIATED ALANINE PELLETS - THE IMPORTANCE OF PREIRRADATION CONDITIONING [J].
ARBER, JM ;
SHARPE, PHG .
APPLIED RADIATION AND ISOTOPES, 1993, 44 (1-2) :19-22
[9]   Clinical applications of alanine/electron spin resonance dosimetry [J].
Baffa, Oswaldo ;
Kinoshita, Angela .
RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2014, 53 (02) :233-240
[10]   Alanine dosimetry in strong magnetic fields: use as a transfer standard in MRI-guided radiotherapy [J].
Billas, Ilias ;
Bouchard, Hugo ;
Oelfke, Uwe ;
Shipley, David ;
Gouldstone, Clare ;
Duane, Simon .
PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (11)