Management of sensible water uses with real-time measurements

被引:20
作者
Fleischmann, N [1 ]
Staubmann, K [1 ]
Langergraber, G [1 ]
机构
[1] Univ Agr Sci Vienna, BOKU, SIG,IWGA, Dept Sanitary Engn & Water Pollut Control, A-1190 Vienna, Austria
关键词
early warning; monitoring network; surveillance; water quality sensors;
D O I
10.2166/wst.2002.0048
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
For the protection of bankside wells and a groundwater recharge an early warning system had to be developed The monitoring network design is based on sensor measurements only For this purpose a new submersible spectrometer has been successfully tested for multi-parameter measurements directly in the medium The developed system can easily be upgraded with other new sensors Only calibration and validation data are supplied by conventional grab sampling and laboratory analysis A conventional testfilter improved by on-line monitoring at 5 sampling sites serves as a reference system The whole system is equipped with remote control and the internet serves as the control centre of the network All measurement data from all 9 sites are available in real time on the internet.
引用
收藏
页码:33 / 40
页数:8
相关论文
共 3 条
[1]  
Gimbel R., 1987, VOM WASSER, V69, P139
[2]   Light scattering by small particles [J].
Huber, E ;
Frost, M .
JOURNAL OF WATER SERVICES RESEARCH AND TECHNOLOGY-AQUA, 1998, 47 (02) :87-94
[3]  
Staubmann K., 2001, P IWA 2 WORLD WAT C