A lead ion-selective electrode based on a calixarene carboxyphenyl azo derivative

被引:79
|
作者
Lu, JQ
Chen, R
He, XW [1 ]
机构
[1] Nankai Univ, Dept Chem, Tianjin 300071, Peoples R China
[2] Hubei Normal Univ, Dept Chem, Huangshi 435002, Peoples R China
来源
JOURNAL OF ELECTROANALYTICAL CHEMISTRY | 2002年 / 528卷 / 1-2期
基金
中国国家自然科学基金;
关键词
calix[4]arene derivative; lead; ion-selective electrode;
D O I
10.1016/S0022-0728(02)00840-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A lead ion-selective electrode was prepared with polymeric membranes based on a calixarene derivative containing carboxyphenyl azo groups. The electrode gave good Nernstian responses of 29.4 mV per decade for lead in the activity range 10(-6)-10(-2) M. The limit of detection reached 10(-6.1) M and exhibited high selectivity towards alkali, alkaline earth and transition metal ions. Molecular modeling revealed that the complex exists in the cone conformation with the lead ion being bound by the heteroatom group (N=N) on the upper rim of the derivative. (C) 2002 Published by Elsevier Science B.V.
引用
收藏
页码:33 / 38
页数:6
相关论文
共 50 条
  • [21] Nickel ion-selective PVC membrane electrode based on a new t-octyl-calix[6]arene derivative
    Belhamel, K
    Ludwig, R
    Benamor, M
    MICROCHIMICA ACTA, 2005, 149 (1-2) : 145 - 150
  • [22] Fabrication and characterization of potassium ion-selective electrode based on porous silicon
    Zhu, Ziqiang
    Zhang, Jian
    Zhu, Jianzhong
    Lu, Wei
    Zi, Jian
    IEEE SENSORS JOURNAL, 2007, 7 (1-2) : 38 - 42
  • [23] Preparation of Planar Ion-Selective Electrode Based on Conjugated Thiophene Oligomer
    Yu, Shunyang
    Ju, Lan
    Xiong, Tao
    Li, Yancang
    Liu, Yongming
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (08): : 6684 - 6689
  • [24] A New PVC-Membrane Based Ion-Selective Electrode for Perchlorate
    Yari, Abdollah
    Shamsipur, Mojtaba
    De Filippo, Greta
    Lippolis, Vito
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2009, 1 (02): : 60 - 70
  • [25] SENSING OF ANIONIC POLYMERS BY AN ION-SELECTIVE ELECTRODE BASED ON DIONIUM REAGENTS
    OHKI, A
    KAWAMOTO, K
    NAKA, K
    MAEDA, S
    ANALYTICAL SCIENCES, 1992, 8 (01) : 85 - 86
  • [26] Ion-Selective Electrode Based on a Novel Biomimetic Nicotinamide Compound for Phosphate Ion Sensor
    Jeong, Bongjin
    Oh, Jin Seong
    Kim, Do Yeob
    Kim, Dong Gyu
    Kim, Young Il
    Heo, Jungseok
    Lee, Hyung-Kun
    POLYMERS, 2022, 14 (16)
  • [27] Lead(II)-selective ionophores for ion-selective electrodes: A review
    Guzinski, Marcin
    Lisak, Grzegorz
    Kupis, Justyna
    Jasinski, Artur
    Bochenska, Maria
    ANALYTICA CHIMICA ACTA, 2013, 791 : 1 - 12
  • [28] Development and application of a novel lead ion-selective electrode with the alkylamines modified molecular sieve as carrier
    Liqin Li
    Zhenning Yan
    Shuangyan Zhang
    Journal of the Iranian Chemical Society, 2021, 18 : 2853 - 2862
  • [29] Development and application of a novel lead ion-selective electrode with the alkylamines modified molecular sieve as carrier
    Li, Liqin
    Yan, Zhenning
    Zhang, Shuangyan
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2021, 18 (11) : 2853 - 2862
  • [30] Calixazacrown ethers for copper(II) ion-selective electrode
    Park, SJ
    Shon, OJ
    Rim, JA
    Lee, JK
    Kim, JS
    Nam, H
    Kim, H
    TALANTA, 2001, 55 (02) : 297 - 304