A prototype scintillating fibre beam profile monitor for Ion Therapy beams

被引:12
|
作者
Leverington, B. D. [1 ]
Dziewiecki, M. [1 ]
Renner, L. [1 ]
Runze, R. [1 ,2 ]
机构
[1] Heidelberg Univ, Phys Inst, Neuenheimer Feld 226, Heidelberg, Germany
[2] Northwestern Univ, Evanston, IL 60208 USA
来源
关键词
Beam-line instrumentation (beam position and profile monitors; beam-intensity monitors; bunch length monitors); Instrumentation for heavy-ion therapy; Instrumentation for particlebeam therapy; Scintillators and scintillating fibres and light guides; SCANNED PROTON; MONTE-CARLO; CARBON; SYSTEM;
D O I
10.1088/1748-0221/13/05/P05030
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A prototype plastic scintillating fibre based beam profile monitor was tested at the Heidelberg Ion Therapy Centre/Heidelberg Ionenstrahl Therapiezentrum(HIT) in 2016 to determine its beam property reconstruction performance and the feasibility of further developing an expanded system. At HIT protons, helium, carbon, and oxygen ions are available for therapy and experiments. The beam can be scanned in two dimensions using fast deflection magnets. A tracking system is used to monitor beam position and to adjust scanning magnet currents online. A new detector system with a finer granularity and without the drift time delay of the current MWPC system with a similar amount of material along the beamline would prove valuable in patient treatment. The sensitive detector components in the tested prototype detector are double-clad Kuraray SCSF-78MJ scintillating fibres with a diameter of 0.250 mm wound as a thin multi-layer ribbon. The scintillation light is detected at the end of the ribbon with Hamamatsu S11865-64 photodiode arrays with a pitch of 0.8 mm. Commercial or readily available readout electronics have been used to evaluate the system feasibility. The results shown in this paper include the linearity with respect to beam intensity, the RMS of the beam intensity as measured by two planes, along with the RMS of the mean position, and the measured beam width RMS. The Signal-to-Noise ratio of the current system is also measured as an indicator of potential performance. Additionally, the non-linear light yield of the scintillating fibres as measured by the photodiode arrays is compared to two models which describe the light yield as a function of the ion stopping power and Lorentz beta.
引用
收藏
页数:19
相关论文
共 50 条
  • [41] Scintillating detectors for low intensity ion beam monitoring
    Finocchiaro, P
    Amato, A
    Ciavola, G
    Cuttone, G
    Gu, M
    Raia, G
    Rovelli, A
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) : 508 - 511
  • [42] Permanent Magnet for a Beam Profile Monitor
    Kashikhin, V.
    Brown, B.
    Morris, D.
    Robotham, W.
    Tartaglia, M.
    Thurman-Keup, R.
    Velev, G.
    Volk, J.
    Zagel, J.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2014, 24 (03)
  • [43] Development of a Neutral Beam Profile Monitor
    Takahashi, Goh
    Baek, Kwang Yun
    Kawasaki, Naoki
    Komatsubara, Takeshi K.
    Lim, Gei-Youb
    Maeda, Yosuke
    Masuda, Takahiko
    Morii, Hideki
    Naito, Daichi
    Nanjo, Hajime
    Nomura, Tadashi
    Sasao, Noboru
    Sato, Kazufumi
    Shimogawa, Tetsushi
    Shiomi, Kouji
    Tajima, Yasuhisa
    Watanabe, Hiroaki
    Yamanaka, Taku
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2011, 50 (03)
  • [44] A NONDESTRUCTIVE FAST BEAM PROFILE MONITOR
    GRAVES, WS
    BHARADWAJ, V
    MCGINNIS, D
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 364 (01): : 13 - 18
  • [45] SCANNING ELECTRON BEAM PROFILE MONITOR
    REAGAN, D
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1966, 37 (09): : 1190 - &
  • [46] Development of a neutral beam profile monitor
    Department of Physics, Kyoto University, Kyoto 606-8502, Japan
    不详
    不详
    不详
    不详
    不详
    不详
    Jpn. J. Appl. Phys., 3
  • [47] A SCANNING WIRE BEAM PROFILE MONITOR
    STEINBACH, C
    VANROOIJ, M
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1985, 32 (05) : 1920 - 1922
  • [48] Prototype Beam's Eye View Video Monitor
    Barbiere, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S783 - S783
  • [49] Hi'Beam-A: A Pixelated Beam Monitor for the Accelerator of a Heavy-Ion Therapy Facility
    Zhang, Honglin
    Zhang, Yuezhao
    Yang, Haibo
    Qian, Cheng
    Li, Xianqin
    Sun, Xiangming
    Wang, Dong
    Huang, Ran
    Wang, Yao
    Zhou, Wei
    Niu, Xiaoyang
    Zhao, Chengxin
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2021, 68 (08) : 2081 - 2087
  • [50] Scanning with parallel transfer of an electron beam for a transverse profile monitor of an intense ion bunch
    P. V. Logachev
    D. A. Malyutin
    A. A. Starostenko
    Instruments and Experimental Techniques, 2009, 52 : 569 - 573