A prototype scintillating fibre beam profile monitor for Ion Therapy beams

被引:12
|
作者
Leverington, B. D. [1 ]
Dziewiecki, M. [1 ]
Renner, L. [1 ]
Runze, R. [1 ,2 ]
机构
[1] Heidelberg Univ, Phys Inst, Neuenheimer Feld 226, Heidelberg, Germany
[2] Northwestern Univ, Evanston, IL 60208 USA
来源
关键词
Beam-line instrumentation (beam position and profile monitors; beam-intensity monitors; bunch length monitors); Instrumentation for heavy-ion therapy; Instrumentation for particlebeam therapy; Scintillators and scintillating fibres and light guides; SCANNED PROTON; MONTE-CARLO; CARBON; SYSTEM;
D O I
10.1088/1748-0221/13/05/P05030
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A prototype plastic scintillating fibre based beam profile monitor was tested at the Heidelberg Ion Therapy Centre/Heidelberg Ionenstrahl Therapiezentrum(HIT) in 2016 to determine its beam property reconstruction performance and the feasibility of further developing an expanded system. At HIT protons, helium, carbon, and oxygen ions are available for therapy and experiments. The beam can be scanned in two dimensions using fast deflection magnets. A tracking system is used to monitor beam position and to adjust scanning magnet currents online. A new detector system with a finer granularity and without the drift time delay of the current MWPC system with a similar amount of material along the beamline would prove valuable in patient treatment. The sensitive detector components in the tested prototype detector are double-clad Kuraray SCSF-78MJ scintillating fibres with a diameter of 0.250 mm wound as a thin multi-layer ribbon. The scintillation light is detected at the end of the ribbon with Hamamatsu S11865-64 photodiode arrays with a pitch of 0.8 mm. Commercial or readily available readout electronics have been used to evaluate the system feasibility. The results shown in this paper include the linearity with respect to beam intensity, the RMS of the beam intensity as measured by two planes, along with the RMS of the mean position, and the measured beam width RMS. The Signal-to-Noise ratio of the current system is also measured as an indicator of potential performance. Additionally, the non-linear light yield of the scintillating fibres as measured by the photodiode arrays is compared to two models which describe the light yield as a function of the ion stopping power and Lorentz beta.
引用
收藏
页数:19
相关论文
共 50 条
  • [31] In-beam tests of scintillating fibre detectors at MAMI and at GSI
    Achenbach, P.
    Gayoso, C. Ayerbe
    Bernauer, J. C.
    Boehm, R.
    Distler, M. O.
    Doria, L.
    de la Paz, M. Gomez Rodriguez
    Merkel, H.
    Mueller, U.
    Nungesser, L.
    Pochodzalla, J.
    Majos, S. Sanchez
    Schlimme, B. S.
    Walcher, Th.
    Weinriefer, M.
    Debenjak, L.
    Potokar, M.
    Sirca, S.
    Kavatsyuk, M.
    Lepyoshkina, O.
    Minami, S.
    Nakajima, D.
    Rappold, C.
    Saito, T. R.
    Schardt, D.
    Traeger, M.
    Iwase, H.
    Ajimura, S.
    Sakaguchi, A.
    Mizoi, Y.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 593 (03): : 353 - 360
  • [32] AN ONLINE POSITION-MONITOR AND PROFILE MONITOR FOR PHOTON BEAMS
    WILKE, W
    BRUCKEL, H
    HEIL, RD
    KNEISSL, U
    MAIER, HJ
    SCHASCHEK, K
    STROHER, H
    WEBER, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 249 (2-3): : 544 - 546
  • [33] A gas curtain beam profile monitor using beam induced fluorescence for high intensity charged particle beams
    Salehilashkajani, A.
    Zhang, H. D.
    Ady, M.
    Chritin, N.
    Forck, P.
    Glutting, J.
    Jones, O. R.
    Kersevan, R.
    Kumar, N.
    Lefevre, T.
    Marriott-Dodington, T.
    Mazzoni, S.
    Papazoglou, I
    Rossi, A.
    Schneider, G.
    Sedlacek, O.
    Udrea, S.
    Veness, R.
    Welsch, C. P.
    APPLIED PHYSICS LETTERS, 2022, 120 (17)
  • [34] Three-dimensional ion beam-profile monitor for storage rings
    Quinteros, T.
    DeWitt, D.R.
    Paal, A.
    Schuch, R.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1996, 378 (1-2) : 35 - 39
  • [35] Noninterceptive heavy ion beam profile monitor based on residual gas ionization
    Anne, Remy
    Georget, Yvon
    Hue, Robert
    Tribouillard, Christian
    Vignet, Jean Luc
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1993, A329 (1-2) : 21 - 28
  • [36] Three-dimensional ion beam-profile monitor for storage rings
    Quinteros, T
    DeWitt, DR
    Paal, A
    Schuch, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 378 (1-2): : 35 - 39
  • [37] AN ION-BEAM MONITOR
    BRUS, AS
    VELIKOV, AI
    KUZMICHEV, MA
    KLYUKOVICH, VA
    KHORENKO, VK
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1981, 24 (03) : 585 - 588
  • [38] A new scintillating plastic formed by ion beam modification
    Whitman, PG
    Fay, TD
    Bernard, DL
    Sheu, WJ
    Wang, YQ
    Glass, GA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1997, 127 : 716 - 718
  • [39] New scintillating plastic formed by ion beam modification
    Whitman, P.G.
    Fay, T.D.
    Bernard, D.L.
    Sheu, W.J.
    Wang, Y.Q.
    Glass, G.A.
    Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms, 1997, 127-128 : 716 - 718
  • [40] Scintillating detectors for low intensity ion beam monitoring
    Finocchiaro, P
    Amato, A
    Ciavola, G
    Cuttone, G
    Gu, M
    Raia, G
    Rovelli, A
    1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 820 - 823