A prototype scintillating fibre beam profile monitor for Ion Therapy beams

被引:12
|
作者
Leverington, B. D. [1 ]
Dziewiecki, M. [1 ]
Renner, L. [1 ]
Runze, R. [1 ,2 ]
机构
[1] Heidelberg Univ, Phys Inst, Neuenheimer Feld 226, Heidelberg, Germany
[2] Northwestern Univ, Evanston, IL 60208 USA
来源
关键词
Beam-line instrumentation (beam position and profile monitors; beam-intensity monitors; bunch length monitors); Instrumentation for heavy-ion therapy; Instrumentation for particlebeam therapy; Scintillators and scintillating fibres and light guides; SCANNED PROTON; MONTE-CARLO; CARBON; SYSTEM;
D O I
10.1088/1748-0221/13/05/P05030
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A prototype plastic scintillating fibre based beam profile monitor was tested at the Heidelberg Ion Therapy Centre/Heidelberg Ionenstrahl Therapiezentrum(HIT) in 2016 to determine its beam property reconstruction performance and the feasibility of further developing an expanded system. At HIT protons, helium, carbon, and oxygen ions are available for therapy and experiments. The beam can be scanned in two dimensions using fast deflection magnets. A tracking system is used to monitor beam position and to adjust scanning magnet currents online. A new detector system with a finer granularity and without the drift time delay of the current MWPC system with a similar amount of material along the beamline would prove valuable in patient treatment. The sensitive detector components in the tested prototype detector are double-clad Kuraray SCSF-78MJ scintillating fibres with a diameter of 0.250 mm wound as a thin multi-layer ribbon. The scintillation light is detected at the end of the ribbon with Hamamatsu S11865-64 photodiode arrays with a pitch of 0.8 mm. Commercial or readily available readout electronics have been used to evaluate the system feasibility. The results shown in this paper include the linearity with respect to beam intensity, the RMS of the beam intensity as measured by two planes, along with the RMS of the mean position, and the measured beam width RMS. The Signal-to-Noise ratio of the current system is also measured as an indicator of potential performance. Additionally, the non-linear light yield of the scintillating fibres as measured by the photodiode arrays is compared to two models which describe the light yield as a function of the ion stopping power and Lorentz beta.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] A scintillating fibre beam profile monitor for the experimental areas of the SPS at CERN
    Ortega, I.
    Bay, A.
    Haefeli, G.
    Spanggaard, J.
    Tranquille, G.
    APPLICATIONS OF NOVEL SCINTILLATORS FOR RESEARCH AND INDUSTRY 2016 (ANSRI 2016), 2016, 763
  • [2] A beam profile monitor for picoampere low-energy ion beams
    Li, Xiaoxiao
    Liu, Junliang
    Yu, Deyang
    Li, Xin
    Yang, Liping
    Song, Xiaoxun
    Hui, Xinfei
    Li, Jun
    Zhang, Tongmin
    Liu, Huiping
    Kang, Long
    Li, Jinyu
    Fang, Xing
    Zhu, Xiaolong
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2019, 90 (07):
  • [3] A Fibre Optic Beam Profile and Dose Monitor for Ultrahigh Dose Rate (FLASH) Beams
    Bateman, Joseph J.
    Buchanan, Emma
    Corsini, Roberto
    Farabolini, Wilfrid
    Korysko, Pierre
    Larsen, Robert
    Malyzhenkov, Alexander
    Ruiz, Inaki Ortega
    Rieker, Vilde
    Robertson, Cameron
    Gerbershagen, Alexander
    Dosanjh, Manjit
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S3203 - S3205
  • [4] A scintillating triple GEM beam monitor for radiation therapy
    Simon, A.
    Seravalli, E.
    Kreuger, R.
    Hendrikse, J.
    Loeff, E.
    Heijmen, B. J. M.
    van Eijk, C. W. E.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2770 - 2774
  • [5] The XBPF, a new multipurpose scintillating fibre monitor for the measurement of secondary beams at CERN
    Ruiz, I. Ortega
    Fosse, L.
    Franchi, J.
    Frassier, A.
    Fullerton, J.
    Kral, J.
    Lauener, J.
    Schneider, T.
    Tranquille, G.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 951
  • [6] A SCINTILLATING-FIBER PROFILE MONITOR FOR INTENSE PROTON-BEAMS
    BLUMER, H
    EBERSBERGER, C
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 365 (2-3): : 268 - 272
  • [7] A scintillating fiber beam-energy monitor for electron beam therapy
    Aoyama, T
    Maekoshi, H
    Tsuzaka, M
    Koyama, S
    MEDICAL PHYSICS, 1995, 22 (12) : 2101 - 2102
  • [8] Scintillating fibre-based profiler for low intensity ion beams
    Finocchiaro, P.
    Amato, A.
    Ciavola, G.
    Cuttone, G.
    Gu, M.
    Raia, G.
    Rovelli, A.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1997, 385 (01): : 31 - 36
  • [9] A scintillating fibre-based profiler for low intensity ion beams
    Finocchiaro, P
    Amato, A
    Ciavola, G
    Cuttone, G
    Gu, M
    Raia, G
    Rovelli, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 385 (01): : 31 - 36
  • [10] ION-BEAM PROFILE MONITOR
    EERNISSE, EP
    PETERSON, GD
    SCHUELER, DG
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1975, 46 (03): : 266 - 268