Sensor for amperometric determination of ammonia and ammonia-forming enzyme reactions

被引:49
作者
Strehlitz, B
Gründig, B
Kopinke, H
机构
[1] UFZ Helmholtz Ctr Environm Res, Ctr Environm Biotechnol, UbZ, D-04318 Leipzig, Germany
[2] Senslab Gmbh, D-04318 Leipzig, Germany
关键词
amperometric enzyme sensor; polyaniline film; ammonia; screen printed electrode; urea;
D O I
10.1016/S0003-2670(99)00594-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The amperometric ammonia determination by use of a polyaniline-modified screen printed Pt-C electrode at 0.3 V (versus Ag/AgCl on the strip) is shown. The electrochemical pulse polarization method is used for the modification. The effects of basic electrode material, applied potential, pH of buffer solution and possible interferences of other ions were studied. The polyaniline-modified Pt-C electrode measures (NH4)(2)SO4 with a detection limit of 5 mu M, a linear range up to 1 mM and a sensitivity of 40 +/- 20 mu A cm(-2) mM(-1). A new generation of enzyme sensors arises from the immobilization of ammonia-forming enzymes in a poly(carbamoyl)sulphonate hydrogel matrix on the working electrode as it is shown for urease to detect urea. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:11 / 23
页数:13
相关论文
共 47 条
  • [1] Development of an amperometric assay for NH4+_ based on a chemically modified screen-printed NADH sensor
    Abass, AK
    Hart, JP
    Cowell, DC
    Chappell, A
    [J]. ANALYTICA CHIMICA ACTA, 1998, 373 (01) : 1 - 8
  • [2] NUCLEATION, GROWTH AND BRANCHING OF POLYANILINE FROM MICROELECTRODE EXPERIMENTS
    BADE, K
    TSAKOVA, V
    SCHULTZE, JW
    [J]. ELECTROCHIMICA ACTA, 1992, 37 (12) : 2255 - 2261
  • [3] BARTELS U, 1991, CHEM LABOR BIOTECH, V42, P377
  • [4] Berthelot M.P., 1859, Repertoire de Chimice Applique, V1, P284
  • [5] STUDY OF THE ACTION OF GASES ON A POLYPYRROLE FILM
    BLANC, JP
    DEROUICHE, N
    ELHADRI, A
    GERMAIN, JP
    MALEYSSON, C
    ROBERT, H
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1990, 1 (1-6) : 130 - 133
  • [6] DETERMINATION OF AMMONIA AND METHYLAMINES IN AQUEOUS-SOLUTIONS BY ION CHROMATOGRAPHY
    BOUYOUCOS, SA
    [J]. ANALYTICAL CHEMISTRY, 1977, 49 (03) : 401 - 403
  • [7] EFFECT OF METHANOL IN THE MOBILE PHASE ON THE ION CHROMATOGRAPHIC DETERMINATION OF SOME MONO-VALENT CATIONS
    BUECHELE, RC
    REUTTER, DJ
    [J]. JOURNAL OF CHROMATOGRAPHY, 1982, 240 (02): : 502 - 507
  • [8] CAMMAN K, 1977, ARBEITEN IONENSENSIT
  • [9] SUITABLE POTENTIOMETRIC ENZYME SENSORS FOR UREA AND CREATININE
    CAMPANELLA, L
    SAMMARTINO, MP
    TOMASSETTI, M
    [J]. ANALYST, 1990, 115 (06) : 827 - 830
  • [10] CHANG CM, 1995, ANAL CHIM ACTA, V300, P15