A High-Resolution Ultrasonic Ranging System Using Laser Sensing and a Cross-Correlation Method

被引:21
作者
Jia, Lecheng [1 ]
Xue, Bin [2 ]
Chen, Shili [1 ]
Wu, Hanzhong [2 ]
Yang, Xiaoxia [3 ]
Zhai, Jingsheng [2 ]
Zeng, Zhoumo [1 ]
机构
[1] Tianjin Univ, State Key Lab Precis Measurement Technol & Instru, Tianjin 300072, Peoples R China
[2] Tianjin Univ, Sch Marine Sci & Technol, Tianjin 300072, Peoples R China
[3] Tianjin Univ Technol & Educ, Tianjin Key Lab Informat Sensing & Intelligent Co, Tianjin 300222, Peoples R China
来源
APPLIED SCIENCES-BASEL | 2019年 / 9卷 / 07期
基金
中国国家自然科学基金;
关键词
Laser sensing; ultrasonic ranging; acousto-optic effect; cross-correlation; TIME-OF-FLIGHT; PROCESSING TECHNIQUES; DISTANCE MEASUREMENT; UNCERTAINTY; ARRAYS;
D O I
10.3390/app9071483
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Ultrasound has been proven to be a valid tool for ranging, especially in water. In this paper, we design a high-resolution ultrasonic ranging system that uses a thin laser beam as an ultrasonic sensor. The laser sensing provides a noncontact method for ultrasound detection based on acousto-optic diffraction. Unlike conventional methods, the ultrasound transmitted from the transducer is recorded as the reference signal when it first passes through the laser. It can be used to improve the accuracy and resolution of the time-of-flight (TOF) by a cross-correlation method. Transducers with a central frequency of 1 MHz and diameters of 20 mm and 28 mm are used in the experiment. Five targets and a test piece are used to evaluate the ranging performance. The sound velocity is measured by the sound velocity profiler (SVP). The repeatability error of TOF is less than 4 ns, and the theoretical resolution of TOF is 0.4 ns. The results show a measurement resolution within one-tenth of the wavelength of ultrasound and an accuracy better than 0.3 mm for targets at a distance up to 0.8 m. The proposed system has potential applications in underwater ranging and thickness detection.
引用
收藏
页数:17
相关论文
共 44 条
[1]   Characterization of air-coupled ultrasound transducers in the frequency range 40 kHz-2 MHz using light diffraction tomography [J].
Almqvist, M ;
Holm, A ;
Persson, HW ;
Lindström, K .
ULTRASONICS, 2000, 37 (08) :565-575
[2]   A measurement method based on Kalman filtering for ultrasonic time-of-flight estimation [J].
Angrisani, L ;
Baccigalupi, A ;
Lo Moriello, RS .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2006, 55 (02) :442-448
[3]   Fast processing techniques for accurate ultrasonic range measurements [J].
Barshan, B .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2000, 11 (01) :45-50
[4]   Measuring uncertainty of ultrasonic longitudinal phase velocity estimation using different time-delay estimation methods based on cross-correlation: Computational simulation and experiments [J].
Costa-Junior, Jose F. S. ;
Cortela, Guillermo A. ;
Maggi, Luis E. ;
Rocha, Tiago F. D. ;
Pereira, Wagner C. A. ;
Costa-Felix, Rodrigo P. B. ;
Alvarenga, Andre V. .
MEASUREMENT, 2018, 122 :45-56
[5]   Ultrasonic arrays for non-destructive evaluation: A review [J].
Drinkwater, Bruce W. ;
Wilcox, Paul D. .
NDT & E INTERNATIONAL, 2006, 39 (07) :525-541
[6]   High-frequency acousto-optic effects in Bragg reflectors [J].
Farmer, D. J. ;
Akimov, A. V. ;
Gippius, N. A. ;
Bailey, J. ;
Sharp, J. S. ;
Kent, A. J. .
OPTICS EXPRESS, 2014, 22 (12) :15218-15231
[7]   Hilbert transform in vibration analysis [J].
Feldman, Michael .
MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2011, 25 (03) :735-802
[8]   AN ULTRASONIC RANGING SYSTEM FOR STRUCTURAL VIBRATION MEASUREMENTS [J].
FIGUEROA, F ;
BARBIERI, E .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1991, 40 (04) :764-769
[9]   Real-time measurement of ArF excimer laser corneal tissue ablation rates using cross-correlation of laser waveforms [J].
Fisher, Brian T. ;
Hahn, David W. .
OPTICS EXPRESS, 2011, 19 (05) :4231-4241
[10]   Sea trials of bi-static, time-domain, incoherent synthetic aperture sonar [J].
Foo, KY ;
Atkins, PR ;
Collins, T .
ELECTRONICS LETTERS, 2004, 40 (05) :341-343