Automatic Dual-View Mass Detection in Full-Field Digital Mammograms

被引:6
|
作者
Amit, Guy [1 ]
Hashoul, Sharbell [1 ]
Kisilev, Pavel [1 ]
Ophir, Boaz [1 ]
Walach, Eugene [1 ]
Zlotnick, Aviad [1 ]
机构
[1] IBM Res, Haifa, Israel
来源
MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2015, PT II | 2015年 / 9350卷
关键词
Digital Mammography; Automatic Mass Detection; Dual-View; Machine Learning; COMPUTER-AIDED DETECTION; SEGMENTATION;
D O I
10.1007/978-3-319-24571-3_6
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Mammography is the first-line modality for screening and diagnosis of breast cancer. Following the common practice of radiologists to examine two mammography views, we propose a fully automated dual-view analysis framework for breast mass detection in mammograms. The framework combines unsupervised segmentation and random-forest classification to detect and rank candidate masses in cranial-caudal (CC) and mediolateral-oblique (MLO) views. Subsequently, it estimates correspondences between pairs of candidates in the two views. The performance of the method was evaluated using a publicly available full-field digital mammography database (INbreast). Dual-view analysis provided area under the ROC curve of 0.94, with detection sensitivity of 87% at specificity of 90%, which significantly improved single-view performance (72% sensitivity at 90% specificity, 78% specificity at 87% sensitivity, P<0.05). One-to-one mapping of candidate masses from two views facilitated correct estimation of the breast quadrant in 77% of the cases. The proposed method may assist radiologists to efficiently identify and classify breast masses.
引用
收藏
页码:44 / 52
页数:9
相关论文
共 50 条
  • [11] Automatic evaluation of breast density for full-field digital mammography
    Lou, SL
    Fan, Y
    MEDICAL IMAGING 2000: IMAGE PROCESSING, PTS 1 AND 2, 2000, 3979 : 1362 - 1369
  • [12] Radiomics based detection and characterization of suspicious lesions on full field digital mammograms
    Sapate, Suhas G.
    Mahajan, Abhishek
    Talbar, Sanjay N.
    Sable, Nilesh
    Desai, Subhash
    Thakur, Meenakshi
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2018, 163 : 1 - 20
  • [13] Computer-aided detection systems for breast masses: Comparison of performances on full-field digital mammograms and digitized screen-film mammograms
    Wei, Jun
    Hadjiiski, Lubomir M.
    Sahiner, Berkman
    Chan, Heang-Ping
    Ge, Jun
    Roubidoux, Marilyn A.
    Helvie, Mark A.
    Zhou, Chuan
    Wu, Yi-Ta
    Paramagul, Chintana
    Zhang, Yiheng
    ACADEMIC RADIOLOGY, 2007, 14 (06) : 659 - 669
  • [14] Full-field digital mammography
    U Bick
    Breast Cancer Research, 2 (Suppl 2)
  • [15] Full-field digital mammography
    Bick, U
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (12): : 957 - 964
  • [16] Automatic microcalcification and cluster detection for digital and digitised mammograms
    Oliver, Arnau
    Torrent, Albert
    Llado, Xavier
    Tortajada, Meritxell
    Tortajada, Lidia
    Sentis, Melcior
    Freixenet, Jordi
    Zwiggelaar, Reyer
    KNOWLEDGE-BASED SYSTEMS, 2012, 28 : 68 - 75
  • [17] Perceived Sufficiency of Full-Field Digital Mammograms With and Without Irreversible Image Data Compression for Comparison with Next-Year Mammograms
    Destounis, Stamatia
    Somerville, Patricia
    Murphy, Philip
    Seifert, Posy
    JOURNAL OF DIGITAL IMAGING, 2011, 24 (01) : 66 - 74
  • [18] Perceived Sufficiency of Full-Field Digital Mammograms With and Without Irreversible Image Data Compression for Comparison with Next-Year Mammograms
    Stamatia Destounis
    Patricia Somerville
    Philip Murphy
    Posy Seifert
    Journal of Digital Imaging, 2011, 24 : 66 - 74
  • [19] Quantitative comparison of clustered microcalcifications in for-presentation and for-processing mammograms in full-field digital mammography
    Wang, Juan
    Nishikawa, Robert M.
    Yang, Yongyi
    MEDICAL PHYSICS, 2017, 44 (07) : 3726 - 3738
  • [20] Effect of computer-aided detection on independent double reading of paired screen-film and full-field digital screening mammograms
    Skaane, Per
    Kshirsagar, Ashwini
    Stapleton, Sandra
    Young, Kari
    Castellino, Ronald A.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (02) : 377 - 384