Ultra-trace detection of methamphetamine in biological samples using FFT-square wave voltammetry and nano-sized imprinted polymer/MWCNTs-modified electrode

被引:63
作者
Akhoundian, Maedeh [1 ]
Alizadeh, Taher [1 ]
Ganjali, Mohammad Reza [1 ,2 ]
Norouzi, Parviz [1 ]
机构
[1] Univ Tehran, Univ Coll Sci, Fac Chem, Dept Analyt Chem, POB 14155-6455, Tehran, Iran
[2] Univ Tehran Med Sci, Biosensor Res Ctr, Endocrinol & Metab Mol Cellular Sci Inst, Tehran, Iran
关键词
Methamphetamine; Fast Fourier Transform; Stimulant drug; Imprinted polymer; Carbon nanotube; CARBON-PASTE ELECTRODE; SOLID-PHASE MICROEXTRACTION; SENSITIVE DETECTION; MASS-SPECTROMETRY; ALIPHATIC-AMINES; STIMULANT DRUG; AMPHETAMINE; CHROMATOGRAPHY; EXTRACTION; SENSOR;
D O I
10.1016/j.talanta.2019.02.027
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An efficient voltammetric method for trace level monitoring of methamphetamine (MTM) stimulant drug in the human urine and serum samples is established. This method is based on fast fourier transform square wave voltammetric (FFT-SWV) determination of MTM at a molecularly imprinted polymer (MIP)/multi-walled carbon nanotube (MWCNTs)-modified carbon paste electrode. Voltammetric techniques development for electrochemical assay of MTM is a challenge, due to the weak electroactivity of this drug. Herein, MTM-imprinted nanopolymer was synthesized, using a simple precipitation polymerization method. The resulting polymer, along with MWCNT was then used to fabricate the modified carbon paste electrode which showed a well-defined anodic peak for MTM at about +1.0 V(vs. Ag/AgCl); whereas, the related blank electrode exhibited considerably lower signal at the same conditions. Utilizing the highly efficient MIP, MWCNTs (which increased the charge transfer phenomenon at the electrode surface) and the advanced electrochemical technique of FFT-SWV (which increased the created signal intensity) caused this method to be a high sensitive and selective approach for MTM measurement. In the optimum experimental conditions, the proposed sensor, exhibited linear response range of 1.0 x 10(-8) -1.0 x 10(-4) mol L-1 and the detection limit of 8.3 x 10(-10) mol L-1 with acceptable relative standard deviations (RSD%) for real samples (1.0-3.5%). Herein, the first MIP-based voltammetric sensor for MTM which also exhibits the lowest detection limit, ever reported, is introduced. This approach seems to provide an effective way for rapid screening of MTM in human urine and serum samples.
引用
收藏
页码:115 / 123
页数:9
相关论文
共 46 条
[11]   Drug-related mortality and its impact on adult mortality in eight European countries [J].
Bargagli, AM ;
Hickman, M ;
Davoli, M ;
Perucci, CA ;
Schifano, P ;
Buster, M ;
Brugal, T ;
Vicente, J .
EUROPEAN JOURNAL OF PUBLIC HEALTH, 2006, 16 (02) :198-202
[12]   Disposable screen printed sensor for the electrochemical detection of methamphetamine in undiluted saliva [J].
Bartlett, Carrie-Ann ;
Taylor, Sarah ;
Fernandez, Carlos ;
Wanklyn, Ceri ;
Burton, Daniel ;
Enston, Emma ;
Raniczkowska, Aleksandra ;
Black, Murdo ;
Murphy, Lindy .
CHEMISTRY CENTRAL JOURNAL, 2016, 10
[13]   Alternative reinforcer response cost impacts methamphetamine choice in humans [J].
Bennett, J. Adam ;
Stoops, William W. ;
Rush, Craig R. .
PHARMACOLOGY BIOCHEMISTRY AND BEHAVIOR, 2013, 103 (03) :481-486
[14]   Electrochemiluminescence detection of methamphetamine based on a Ru(bpy)32+-doped silica nanoparticles/Nafion composite film modified electrode [J].
Cai, Zhimin ;
Lin, Zhijie ;
Chen, Xiaomei ;
Jia, Tiantian ;
Yu, Ping ;
Chen, Xi .
LUMINESCENCE, 2010, 25 (05) :367-372
[15]   Simultaneous chiral analysis of methamphetamine and related compounds by capillary electrophoresis [J].
Chinaka, S ;
Tanaka, S ;
Takayama, N ;
Komai, K ;
Ohshima, T ;
Ueda, K .
JOURNAL OF CHROMATOGRAPHY B, 2000, 749 (01) :111-118
[16]   A sol-gel colorimetric sensor for methamphetamine detection [J].
Choodum, Aree ;
Kanatharana, Proespichaya ;
Wongniramaikul, Worawit ;
NicDaeid, Niamh .
SENSORS AND ACTUATORS B-CHEMICAL, 2015, 215 :553-560
[17]   Solid phase microextraction with liquid chromatography-electrospray ionization-tandem mass spectrometry for analysis of amphetamine and methamphetamine in serum [J].
Chou, CC ;
Lee, MR .
ANALYTICA CHIMICA ACTA, 2005, 538 (1-2) :49-56
[18]   An electrochemiluminescent sensor for methamphetamine hydrochloride based on multiwall carbon nanotube/ionic liquid composite electrode [J].
Dai, Hong ;
Wang, Youmei ;
Wu, Xiaoping ;
Zhang, Lan ;
Chen, Guonan .
BIOSENSORS & BIOELECTRONICS, 2009, 24 (05) :1230-1234
[19]   A dysprosium nanowire modified carbon paste electrode for determination of levodopa using fast Fourier transformation square-wave voltammetry method [J].
Daneshgar, Parandis ;
Norouzi, Parviz ;
Ganjali, Mohammad Reza ;
Ordikhani-Seyedlar, Amin ;
Eshraghi, Hasan .
COLLOIDS AND SURFACES B-BIOINTERFACES, 2009, 68 (01) :27-32
[20]   Polypeptide with electroactive endgroups as sensing platform for the abused drug 'methamphetamine' by bioelectrochemical method [J].
Demir, Bilal ;
Yilmaz, Tulay ;
Guler, Emine ;
Gumus, Z. Pinar ;
Akbulut, Huseyin ;
Aldemir, Ebru ;
Coskunol, Hakan ;
Colak, Demet Goen ;
Cianga, Ioan ;
Yamada, Shuhei ;
Timur, Suna ;
Endo, Takeshi ;
Yagci, Yusuf .
TALANTA, 2016, 161 :789-796