Development of a baby friendly non-contact method for measuring vital signs: first results of clinical measurements in an open incubator at a Neonatal Intensive Care Unit

被引:35
作者
Klaessens, John H. G. M. [1 ]
van den Born, Marlies [1 ]
van der Veen, Albert [1 ]
Sikkens-van de Kraats, Janine [1 ]
van den Dungen, Frank A. M. [2 ]
Verdaasdonk, Rudolf M. [1 ]
机构
[1] Vrije Univ Amsterdam, Med Ctr, Dept Phys & Med Technol, Amsterdam, Netherlands
[2] Vrije Univ Amsterdam Med Ctr, Dept Pediat, Amsterdam, Netherlands
来源
ADVANCED BIOMEDICAL AND CLINICAL DIAGNOSTIC AND SURGICAL GUIDANCE SYSTEMS XII | 2014年 / 8935卷
关键词
Non-contact; vital signs; thermography; photoplethysmography; Algorithms; HEART;
D O I
10.1117/12.2038353
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
For infants and neonates in an incubator vital signs, such as heart rate, breathing, skin temperature and blood oxygen saturation are measured by sensors and electrodes sticking to the skin. This can damage the vulnerable skin of neonates and cause infections. In addition, the wires interfere with the care and hinder the parents in holding and touching the baby. These problems initiated the search for baby friendly 'non-contact' measurement of vital signs. Using a sensitive color video camera and specially developed software, the heart rate was derived from subtle repetitive color changes. Potentially also respiration and oxygen saturation could be obtained. A thermal camera was used to monitor the temperature distribution of the whole body and detect small temperature variations around the nose revealing the respiration rate. After testing in the laboratory, seven babies were monitored (with parental consent) in the neonatal intensive care unit (NICU) simultaneously with the regular monitoring equipment. From the color video recordings accurate heart rates could be derived and the thermal images provided accurate respiration rates. To correct for the movements of the baby, tracking software could be applied. At present, the image processing was performed off-line. Using narrow band light sources also non-contact blood oxygen saturation could be measured. Non-contact monitoring of vital signs has proven to be feasible and can be developed into a real time system. Besides the application on the NICU non-contact vital function monitoring has large potential for other patient groups.
引用
收藏
页数:7
相关论文
共 19 条
[1]   Non-contact heart rate monitoring utilizing camera photoplethysmography in the neonatal intensive care unit - A pilot study [J].
Aarts, Lonneke A. M. ;
Jeanne, Vincent ;
Cleary, John P. ;
Lieber, C. ;
Nelson, J. Stuart ;
Oetomo, Sidarto Bambang ;
Verkruysse, Wim .
EARLY HUMAN DEVELOPMENT, 2013, 89 (12) :943-948
[2]   Neonatal non-contact respiratory monitoring based on real-time infrared thermography [J].
Abbas, Abbas K. ;
Heimann, Konrad ;
Jergus, Katrin ;
Orlikowsky, Thorsten ;
Leonhardt, Steffen .
BIOMEDICAL ENGINEERING ONLINE, 2011, 10
[3]  
Eichenfield Lawrence F., 1999, Current Opinion in Pediatrics, V11, P471, DOI 10.1097/00008480-199910000-00017
[4]   Non-contact monitoring of heart and lung activity using magnetic induction measurement in a neonatal animal model [J].
Heimann, Konrad ;
Steffen, Matthias ;
Bernstein, Nina ;
Heerich, Nora ;
Stanzel, Sven ;
Cordes, Axel ;
Leonhardt, Steffen ;
Wenzl, Tobias G. ;
Orlikowsky, Thorsten .
BIOMEDIZINISCHE TECHNIK, 2009, 54 (06) :337-345
[5]   Noncontact monitoring of vascular lesion phototherapy efficiency by RGB multispectral imaging [J].
Jakovels, Dainis ;
Kuzmina, Ilona ;
Berzina, Anna ;
Valeine, Lauma ;
Spigulis, Janis .
JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (12)
[6]   2-D mapping of skin chromophores in the spectral range 500-700 nm [J].
Jakovels, Dainis ;
Spigulis, Janis .
JOURNAL OF BIOPHOTONICS, 2010, 3 (03) :125-129
[7]   Cellular phone-based photoplethysmographic imaging [J].
Jonathan, Enock ;
Leahy, Martin J. .
JOURNAL OF BIOPHOTONICS, 2011, 4 (05) :293-296
[8]  
Klaessens J. H. G. M., 2013, SPIE BIOS P, V8572
[9]  
Klaessens J. H. G. M., 2013, SPIE BIOS P, V8574
[10]  
Klaessens J. H. G. M., 2008, SPIE P, V6848